1727429936000 | 0 | None | None | Other Works | Construction of bus stands at KUD, Hanumanth nagar, Hoysal nagar, Kalyan nagar area, near Shanti sadan school and near Shalmala school hanumanth nagar in ward no 18 Dharwad | 2534323.94 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4094177 | 159448 | None | 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 52.95 | False | None | None | False | None | False | 5670.945 | 0 | 4094178 | 159448 | None | 2.1.2 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. | Cum | 5947.2 | 5947.2 | 20.27 | False | None | None | False | None | False | 120549.744 | 0 | 4094179 | 159448 | None | 5.40 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 25.56 | False | None | None | False | None | False | 171467.982 | 0 | 4094180 | 159448 | None | 6.30 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 9317.7 | 9317.7 | 9.21 | False | None | None | False | None | False | 85816.017 | 0 | 4094181 | 159448 | None | 1.80 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 23.63 | False | None | None | False | None | False | 11760.651 | 0 | 4094182 | 159448 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 17.98 | False | None | None | False | None | False | 125167.77 | 0 | 4094183 | 159448 | None | 007 | Centering and shuttering for Footing 5% | Cum | 348.08 | 348.08 | 7.5 | False | None | None | False | None | False | 2610.6 | 0 | 4094184 | 159448 | None | 008 | Centering and shuttering for column 70% | Cum | 4873.05 | 4873.05 | 4.28 | False | None | None | False | None | False | 20856.654 | 0 | 4094185 | 159448 | None | 009 | Centering and shuttering for Lintel Beam 60% | Cum | 4176.9 | 4176.9 | 6.21 | False | None | None | False | None | False | 25938.549 | 0 | 4094186 | 159448 | None | 2.11a | Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and technical specification | Tonne | 93929.85 | 93929.85 | 2.1 | False | None | None | False | None | False | 197252.685 | 0 | 4094187 | 159448 | None | 2.1.4 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 6.39 | False | None | None | False | None | False | 41712.9615 | 0 | 4094188 | 159448 | None | sl no 202 A-18 | Chequered precast cement concrete tiles 22mm thick using marble chips of size 6mm - Light shade using white cement | Sqm | 498.75 | 498.75 | 93.3 | False | None | None | False | None | False | 46533.375 | 0 | 4094189 | 159448 | None | 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thickcement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finishedwith a top layer 6 mm thick cement plaster with cement mortar 1:6 (1cement : 6 fine sand) to brick masonry including rounding off cornerswherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specificationsand as per directions of Engineer-in-charge.
| Sqm | 389.55 | 389.55 | 42.6 | False | None | None | False | None | False | 16594.83 | 0 | 4094190 | 159448 | None | 11.15.2 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer: Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of th Engineer-in-Charge.
| Kg | 123.9 | 123.9 | 4050.0 | False | None | None | False | None | False | 501795.0 | 0 | 4094191 | 159448 | None | 8.4 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 120.75 | 120.75 | 75.0 | False | None | None | False | None | False | 9056.25 | 0 | 4094192 | 159448 | None | 7.6 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. (0.63 mm thick with zinc coating not less than 275 g/m²) | m | 677.25 | 677.25 | 60.0 | False | None | None | False | None | False | 40635.0 | 0 | 4094193 | 159448 | None | 7.1.1 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. | Sqm | 922.95 | 922.95 | 90.0 | False | None | None | False | None | False | 83065.5 | 0 | 4094194 | 159448 | None | 13.33.9 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 100 mm nominal dia Pipes | Rmtr | 2650.2 | 2650.2 | 50.0 | False | None | None | False | None | False | 132510.0 | 0 | 4094195 | 159448 | None | 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kgs | 593.25 | 593.25 | 1128.38 | False | None | None | False | None | False | 669411.435 | 0 | 4094196 | 159448 | None | 8.48 | Supply and installation of retro- reflective Chevron signboards of 600x450mm made out of cube corner micro prismatic grade sheeting confirming to Type XI standards of IRC:67:2022 & ASTM D 4956-09 specification & fixed over 3 mm thick Aluminium Composite Panel sheet having minimum 0.30 mm thick aluminum skin on both sides & fixed over back support frame of 25x25x 3mm MS angle frame. Supported on 75 mm dia OR 75x75x6mm Mild steel with clear height of not less than 2.1 m from the ground level to the bottom of the Sign board & 60 cm below ground level. The sign post should be painted with one coat of red oxide paint and two coats of synthetic enamel paint of black and white colour with bands of 30 cm height, firmly fixed to the ground by means of foundation with M 20 grade cement, concrete foundation size of 45 cm x 45 cm x 60 cm including cost & conveyance of all materials, equipment,machinery & Labour with all leads and lifts for satisfactory completion of the work as directed by Engineer incharge. | Nos | 3765.3 | 3765.3 | 60.0 | False | None | None | False | None | False | 225918.0 | 0 |
|