tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1727449390000 | 0 | None | None | Buildings | Construction Of Office/ Godown Building to Multipropose Pratamikka Gramina Krushi Sahakari Sangh Limited Chinchani village At Chikodi Taluka of Belagavi District | 1642911.79 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4098640 | 159659 | None | code01 | Earth work excavation for Foundation by mechanical means for all works &depth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the excavated earth or sorting& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenacesrequired to complete the work In all kinds of soils Depth upto 3 m complete as per direction of the Engineer-in-charge of the work | Cum | 603.75 | 603.75 | 86.81 | False | None | None | False | None | False | 52411.5375 | 0 | 4098641 | 159659 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the work | Cum | 6527.85 | 6527.85 | 19.34 | False | None | None | False | None | False | 126248.619 | 0 | 4098642 | 159659 | None | code03 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the work | Cum | 6601.35 | 6601.35 | 13.5 | False | None | None | False | None | False | 89118.225 | 0 | 4098643 | 159659 | None | code04 | Formwork & Centring Charges @ 8% complete as per direction of the Engineer-in-charge of the work | Cum | 528.11 | 528.11 | 13.5 | False | None | None | False | None | False | 7129.485 | 0 | 4098644 | 159659 | None | code05 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the work | Cum | 6639.15 | 6639.15 | 6.52 | False | None | None | False | None | False | 43287.258 | 0 | 4098645 | 159659 | None | code06 | Formwork & Centring Charges @ 70% complete as per direction of the Engineer-in-charge of the work | Cum | 4647.41 | 4647.41 | 6.52 | False | None | None | False | None | False | 30301.1132 | 0 | 4098646 | 159659 | None | code07 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.complete as per direction of the Engineer-in-charge of the work | Cum | 8376.9 | 8376.9 | 5.94 | False | None | None | False | None | False | 49758.786 | 0 | 4098647 | 159659 | None | code08 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the work | Cum | 6639.15 | 6639.15 | 4.17 | False | None | None | False | None | False | 27685.2555 | 0 | 4098648 | 159659 | None | code09 | Formwork & Centring Charges @ 60% complete as per direction of the Engineer-in-charge of the work | Cum | 3983.49 | 3983.49 | 4.17 | False | None | None | False | None | False | 16611.1533 | 0 | 4098649 | 159659 | None | code10 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all complete as per direction of the Engineer-in-charge of the work | Cum | 497.7 | 497.7 | 122.5 | False | None | None | False | None | False | 60968.25 | 0 | 4098650 | 159659 | None | code11 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.complete as per direction of the Engineer-in-charge of the work | Cum | 8367.45 | 8367.45 | 21.43 | False | None | None | False | None | False | 179314.4535 | 0 | 4098651 | 159659 | None | code12 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the work | Cum | 6961.5 | 6961.5 | 1.1 | False | None | None | False | None | False | 7657.65 | 0 | 4098652 | 159659 | None | code13 | Formwork & Centring Charges @ 60% complete as per direction of the Engineer-in-charge of the work | Cum | 4176.9 | 4176.9 | 1.1 | False | None | None | False | None | False | 4594.59 | 0 | 4098653 | 159659 | None | code14 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the work | Cum | 6961.5 | 6961.5 | 1.11 | False | None | None | False | None | False | 7727.265 | 0 | 4098654 | 159659 | None | code15 | Formwork & Centring Charges @ 45% complete as per direction of the Engineer-in-charge of the work | Cum | 3132.68 | 3132.68 | 1.11 | False | None | None | False | None | False | 3477.2748 | 0 | 4098655 | 159659 | None | code16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the work | Cum | 6961.5 | 6961.5 | 6.63 | False | None | None | False | None | False | 46154.745 | 0 | 4098656 | 159659 | None | code17 | Formwork & Centring Charges @ 60% complete as per direction of the Engineer-in-charge of the work | Cum | 4176.9 | 4176.9 | 6.63 | False | None | None | False | None | False | 27692.847 | 0 | 4098657 | 159659 | None | code18 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the work | Cum | 6961.5 | 6961.5 | 9.15 | False | None | None | False | None | False | 63697.725 | 0 | 4098658 | 159659 | None | code19 | Formwork & Centring Charges @ 50% complete as per direction of the Engineer-in-charge of the work | Cum | 3480.75 | 3480.75 | 9.15 | False | None | None | False | None | False | 31848.8625 | 0 | 4098659 | 159659 | None | code20 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 complete as per direction of the Engineer-in-charge of the work | Cum | 645.75 | 645.75 | 73.23 | False | None | None | False | None | False | 47288.2725 | 0 | 4098660 | 159659 | None | code21 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. complete as per direction of the Engineer-in-charge of the work | Kgs | 93.93 | 93.93 | 3670.06 | False | None | None | False | None | False | 344728.7358 | 0 | 4098661 | 159659 | None | code22 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mms complete as per direction of the Engineer-in-charge of the work | Cum | 2764.65 | 2764.65 | 4.392 | False | None | None | False | None | False | 12142.3428 | 0 | 4098662 | 159659 | None | code23 | Providing and fxing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 176.4 | 176.4 | 196.56 | False | None | None | False | None | False | 34673.184 | 0 | 4098663 | 159659 | None | code24 | Providing & fixing of 3 track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wallthickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm | Sqm | 7070.7 | 7070.7 | 9.36 | False | None | None | False | None | False | 66181.752 | 0 | 4098664 | 159659 | None | code25 | Providing 20 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 coarse sand) fnished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fne sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 349.65 | 349.65 | 146.73 | False | None | None | False | None | False | 51304.1445 | 0 | 4098665 | 159659 | None | code26 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fne sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 292.95 | 292.95 | 105.64 | False | None | None | False | None | False | 30947.238 | 0 | 4098666 | 159659 | None | code27 | Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fne sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 65.68 | False | None | None | False | None | False | 17585.82 | 0 | 4098667 | 159659 | None | code28 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, lishing complete as per direction of the Engineer-in-charge of the work | Sqm | 1622.25 | 1622.25 | 65.58 | False | None | None | False | None | False | 106387.155 | 0 | 4098668 | 159659 | None | code29 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 171.32 | False | None | None | False | None | False | 24644.382 | 0 | 4098669 | 159659 | None | code30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the work | Sqm | 182.7 | 182.7 | 146.73 | False | None | None | False | None | False | 26807.571 | 0 | 4098670 | 159659 | None | code31 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 31.08 | False | None | None | False | None | False | 4536.126 | 0 |
| 1727449390000 | 0 | None | None | Buildings | ELECTRIFICATION | 47664.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4098671 | 159660 | None | code01 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required. 25mm complete as per direction of the Engineer-in-charge of the work | Mtr | 35.0 | 35.0 | 60.0 | False | None | None | False | None | False | 2100.0 | 0 | 4098672 | 159660 | None | code02 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPERconductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A Short point upto 3Mtr from tapping point to out let via switch box complete as per direction of the Engineer-in-charge of the work | Point | 285.0 | 285.0 | 5.0 | False | None | None | False | None | False | 1425.0 | 0 | 4098673 | 159660 | None | code03 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box complete as per direction of the Engineer-in-charge of the work | Point | 394.0 | 394.0 | 5.0 | False | None | None | False | None | False | 1970.0 | 0 | 4098674 | 159660 | None | code04 | Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box complete as per direction of the Engineer-in-charge of the work | Point | 570.0 | 570.0 | 2.0 | False | None | None | False | None | False | 1140.0 | 0 | 4098675 | 159660 | None | code05 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS694: 1990 & confirming to GTP of GROUP A. 1.5 sqmm complete as per direction of the Engineer-in-charge of the work | Mtr | 26.0 | 26.0 | 55.0 | False | None | None | False | None | False | 1430.0 | 0 | 4098676 | 159660 | None | code06 | 2.5 sqmm complete as per direction of the Engineer-in-charge of the work | Mtr | 42.0 | 42.0 | 80.0 | False | None | None | False | None | False | 3360.0 | 0 | 4098677 | 159660 | None | code07 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way complete as per direction of the Engineer-in-charge of the work | Each | 261.0 | 261.0 | 4.0 | False | None | None | False | None | False | 1044.0 | 0 | 4098678 | 159660 | None | code08 | 10-12Way complete as per direction of the Engineer-in-charge of the work | Each | 319.0 | 319.0 | 3.0 | False | None | None | False | None | False | 957.0 | 0 | 4098679 | 159660 | None | code09 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module complete as per direction of the Engineer-in-charge of the work | Each | 284.0 | 284.0 | 2.0 | False | None | None | False | None | False | 568.0 | 0 | 4098680 | 159660 | None | code10 | 10-12 Module complete as per direction of the Engineer-in-charge of the work | Each | 344.0 | 344.0 | 2.0 | False | None | None | False | None | False | 688.0 | 0 | 4098681 | 159660 | None | code11 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A. 6 Amps one way Switch complete as per direction of the Engineer-in-charge of the work | Each | 102.0 | 102.0 | 3.0 | False | None | None | False | None | False | 306.0 | 0 | 4098682 | 159660 | None | code12 | 6Amps 3 way Socket complete as per direction of the Engineer-in-charge of the work | Each | 171.0 | 171.0 | 2.0 | False | None | None | False | None | False | 342.0 | 0 | 4098683 | 159660 | None | code13 | Stepped fan Regulator complete as per direction of the Engineer-in-charge of the work | Each | 357.0 | 357.0 | 3.0 | False | None | None | False | None | False | 1071.0 | 0 | 4098684 | 159660 | None | code14 | 32 Amps Dp switch complete as per direction of the Engineer-in-charge of the work | Each | 326.0 | 326.0 | 2.0 | False | None | None | False | None | False | 652.0 | 0 | 4098685 | 159660 | None | code15 | Supplying & Fixing of 70-150 W lamp holder 2 Pin complete as per direction of the Engineer-in-charge of the work | Each | 63.0 | 63.0 | 4.0 | False | None | None | False | None | False | 252.0 | 0 | 4098686 | 159660 | None | code16 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 16Amps complete as per direction of the Engineer-in-charge of the work | Each | 157.0 | 157.0 | 2.0 | False | None | None | False | None | False | 314.0 | 0 | 4098687 | 159660 | None | code17 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT. complete as per direction of the Engineer-in-charge of the work | Each | 1703.0 | 1703.0 | 2.0 | False | None | None | False | None | False | 3406.0 | 0 | 4098688 | 159660 | None | code18 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5-32 Amps SP complete as per direction of the Engineer-in-charge of the work | Each | 415.0 | 415.0 | 2.0 | False | None | None | False | None | False | 830.0 | 0 | 4098689 | 159660 | None | code19 | Supplying and fixing of 5'-80 W of T8 Fluorescent Tube with
54W power consumption with low 3mg Mercury content less
phosphor coating Operating voltage range from 180V to 265V,
50Hz AC power Supply. complete as per direction of the Engineer-in-charge of the work | Each | 520.0 | 520.0 | 6.0 | False | None | None | False | None | False | 3120.0 | 0 | 4098690 | 159660 | None | code20 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / Watt, Three Blades of blade leaf 1.05mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty 48" Sweep 5 Star (1200 mm) complete as per direction of the Engineer-in-charge of the work | Each | 4303.0 | 4303.0 | 4.0 | False | None | None | False | None | False | 17212.0 | 0 | 4098691 | 159660 | None | code21 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. (on wall/ceiling/rafter/girders complete as per direction of the Engineer-in-charge of the work | Each | 122.0 | 122.0 | 3.0 | False | None | None | False | None | False | 366.0 | 0 | 4098692 | 159660 | None | code22 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 10sqmm complete as per direction of the Engineer-in-charge of the work | Mtr | 167.0 | 167.0 | 12.0 | False | None | None | False | None | False | 2004.0 | 0 | 4098693 | 159660 | None | code23 | Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts, 50Hz AC supply & completely wired on existing box complete as per direction of the Engineer-in-charge of the work | Each | 646.0 | 646.0 | 1.0 | False | None | None | False | None | False | 646.0 | 0 | 4098694 | 159660 | None | code24 | LT AC Single Phase 2 Wire, 5-30 Amps Smart Energy
Meter, Class 1.0 Accuracy with RF Communication