1727446590000 | 0 | None | None | Buildings | Improvements/Re-Construction of toilets with soakpits and other allied works to quarters premises at 66/11kV Sub-Station, Bagepalli | 1499800.87 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4098559 | 159656 | None | Code01 | Demolishing brick work manually/ by mechanical means including stack ing of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar(V-2, P-187, I-19.7.3) | Cum | 1250.6 | 1250.6 | 21.63 | False | None | None | False | None | False | 27050.478 | 0 | 4098560 | 159656 | None | Code02 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings and bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools and other appurtenaces required to complete the work. (Vol-1, p-5, I-1.4.1) | Cum | 294.13 | 294.13 | 48.0 | False | None | None | False | None | False | 14118.24 | 0 | 4098561 | 159656 | None | Code03 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (Vol-1,p-15,i-2.1.2) | Cum | 6884.03 | 6884.03 | 17.25 | False | None | None | False | None | False | 118749.5175 | 0 | 4098562 | 159656 | None | Code04 | Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (V-2,P-9, I-5.4) | Cum | 7765.19 | 7765.19 | 41.25 | False | None | None | False | None | False | 320314.0875 | 0 | 4098563 | 159656 | None | Code05 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates for PCC (Vol-1, p-15, I-2.1.6) | Cum | 7587.74 | 7587.74 | 8.2 | False | None | None | False | None | False | 62219.468 | 0 | 4098564 | 159656 | None | Code06 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Vol-2, p-17, I-6.32) | Sqm | 1592.17 | 1592.17 | 136.0 | False | None | None | False | None | False | 216535.12 | 0 | 4098565 | 159656 | None | Code07 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse (Vol-1, p-15, I-2.2.1)+50% shuttering | Cum | 11461.83 | 11461.83 | 6.5 | False | None | None | False | None | False | 74501.895 | 0 | 4098566 | 159656 | None | Code08 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Vol-2, p-41, I-8.3.2) | Sqm | 404.73 | 404.73 | 414.0 | False | None | None | False | None | False | 167558.22 | 0 | 4098567 | 159656 | None | Code09 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (V-2, P-41, I-8.4.2) | Sqm | 379.2 | 379.2 | 30.5 | False | None | None | False | None | False | 11565.6 | 0 | 4098568 | 159656 | None | Code10 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. (V-2, P-60, I-9.9) | Sqm | 1307.77 | 1307.77 | 29.0 | False | None | None | False | None | False | 37925.33 | 0 | 4098569 | 159656 | None | Code11 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete.(V-2,P-71,I-10.14) | Sqm | 1344.23 | 1344.23 | 54.0 | False | None | None | False | None | False | 72588.42 | 0 | 4098570 | 159656 | None | Code12 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge (V-2, P-50, I-8.51) | Sqm | 121.54 | 121.54 | 115.0 | False | None | None | False | None | False | 13977.1 | 0 | 4098571 | 159656 | None | Code13 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(v-2, p-46,I-8.32) | Sqm | 189.6 | 189.6 | 115.0 | False | None | None | False | None | False | 21804.0 | 0 | 4098572 | 159656 | None | Code14 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt and pick up resistant, Alkali and Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge(Vol-2, p-45, I-8.31) | Sqm | 216.34 | 216.34 | 195.0 | False | None | None | False | None | False | 42186.3 | 0 | 4098573 | 159656 | None | Code15 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification(Vol-1, p-18, I-2.11h) | Kg | 96.03 | 96.03 | 360.0 | False | None | None | False | None | False | 34570.8 | 0 | 4098574 | 159656 | None | Code16 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m.(Vol-1, p-7, I-1.9) | Cum | 323.3 | 323.3 | 22.0 | False | None | None | False | None | False | 7112.6 | 0 | 4098575 | 159656 | None | Code17 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work(Vol-3, p-17, I-3.1) | Cum | 103.31 | 103.31 | 48.0 | False | None | None | False | None | False | 4958.88 | 0 | 4098576 | 159656 | None | Code18 | Constructing brick masonry chamber of internal dimension 450X450 mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover(V-5, P-191, I-16.10) | Each | 5148.43 | 5148.43 | 8.0 | False | None | None | False | None | False | 41187.44 | 0 | 4098577 | 159656 | None | Code19 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests(V-2, P-134, I-14.1.1) | Each | 5936.01 | 5936.01 | 8.0 | False | None | None | False | None | False | 47488.08 | 0 | 4098578 | 159656 | None | Code20 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete for PVC pipes 110mm dia., 6kg/sqcm class-3(V-5, P-113, I-10.1.7) | m | 499.53 | 499.53 | 48.0 | False | None | None | False | None | False | 23977.44 | 0 | 4098579 | 159656 | None | Code21 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usageand other appurtenances required to complete the work.(V-1, P-6. I-1.6.1) | Cum | 588.25 | 588.25 | 8.1 | False | None | None | False | None | False | 4764.825 | 0 | 4098580 | 159656 | None | Code22 | Providing flooring with 25mm thick polished Cuddapah slabs including cost of materials, labour, curing, polishing complete as per specifications.(DR) | Sqm | 1499.5 | 1499.5 | 8.0 | False | None | None | False | None | False | 11996.0 | 0 | 4098581 | 159656 | None | Code23 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm) (V-6, P-13,I-32.02) | m | 96.3 | 96.3 | 80.0 | False | None | None | False | None | False | 7704.0 | 0 | 4098582 | 159656 | None | Code24 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20 mm dia 2 mm thick (V-6, P-2, I-1.1.1) | m | 83.86 | 83.86 | 32.0 | False | None | None | False | None | False | 2683.52 | 0 | 4098583 | 159656 | None | Code25 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase and Neutral) and 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Long point above 6Mtr upto 10Mtr from tapping point to out let via switch (V-6, P-5, I-2.1.3) | No | 692.78 | 692.78 | 16.0 | False | None | None | False | None | False | 11084.48 | 0 | 4098584 | 159656 | None | Code26 | Supplying and Fixing of 70-150 W lamp holder 2 Pin (V6, P-52, I-12.46) | No | 76.57 | 76.57 | 16.0 | False | None | None | False | None | False | 1225.12 | 0 | 4098585 | 159656 | None | Code27 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way (V6, P-8, I-3.4.2) | Each | 193.25 | 193.25 | 8.0 | False | None | None | False | None | False | 1546.0 | 0 | 4098586 | 159656 | None | Code28 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module(V-6, P-8, I-3.5.2) | Each | 195.7 | 195.7 | 8.0 | False | None | None | False | None | False | 1565.6 | 0 | 4098587 | 159656 | None | Code29 | Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box (V-6, P-2, I-1.5.1) | Each | 59.55 | 59.55 | 16.0 | False | None | None | False | None | False | 952.8 | 0 | 4098588 | 159656 | None | Code30 | Providing and fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made) (V-2, P-109, I-12.85) | Sqm | 6950.87 | 6950.87 | 2.16 | False | None | None | False | None | False | 15013.8792 | 0 | 4098589 | 159656 | None | Code31 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximumtoxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) and 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness (V-2, P-111, I-12.94.1) | Sqm | 4235.67 | 4235.67 | 11.52 | False | None | None | False | None | False | 48794.9184 | 0 | 4098590 | 159656 | None | Code32 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows and other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm (V-2, P-111, I-12.93.1) | m | 853.21 | 853.21 | 37.6 | False | None | None | False | None | False | 32080.696 | 0 |
|