4097299 | 159620 | None | code01 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. - In all kinds of soils upto 300 mm depth | Cum | 95.0 | 95.0 | 276.0 | False | None | None | False | None | False | 26220.0 | 0 |
4097300 | 159620 | None | code02 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. - In all kinds of soils upto 300 mm depth | Cum | 362.0 | 362.0 | 276.0 | False | None | None | False | None | False | 99912.0 | 0 |
4097301 | 159620 | None | code03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work - In all kinds of soils - Depth upto 3 m | Cum | 102.0 | 102.0 | 709.23 | False | None | None | False | None | False | 72341.46 | 0 |
4097302 | 159620 | None | code04 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- n all kinds of soils - In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 363.0 | 363.0 | 674.191 | False | None | None | False | None | False | 244731.333 | 0 |
4097303 | 159620 | None | code05 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. - In all kinds of soils Depth upto 1.5 m | Cum | 242.0 | 242.0 | 119.8 | False | None | None | False | None | False | 28991.6 | 0 |
4097304 | 159620 | None | code06 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 118.0 | 118.0 | 941.08 | False | None | None | False | None | False | 111047.44 | 0 |
4097305 | 159620 | None | code07 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5664.0 | 5664.0 | 97.96 | False | None | None | False | None | False | 554845.44 | 0 |
4097306 | 159620 | None | code08 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5989.0 | 5989.0 | 98.58 | False | None | None | False | None | False | 590395.62 | 0 |
4097307 | 159620 | None | code09 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - For FOOTINGS | Cum | 6842.88 | 6842.88 | 212.67 | False | None | None | False | None | False | 1455275.2896 | 0 |
4097308 | 159620 | None | code10 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) -M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6336.0 | 6336.0 | 2.2 | False | None | None | False | None | False | 13939.2 | 0 |
4097309 | 159620 | None | code11 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) -M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Raft | Cum | 6526.08 | 6526.08 | 12.0 | False | None | None | False | None | False | 78312.96 | 0 |
4097310 | 159620 | None | code12 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) -M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Slab | Cum | 9504.0 | 9504.0 | 4.69 | False | None | None | False | None | False | 44573.76 | 0 |
4097311 | 159620 | None | code13 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) -M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For PEDESTAL | Cum | 10771.2 | 10771.2 | 33.57 | False | None | None | False | None | False | 361589.184 | 0 |
4097312 | 159620 | None | code14 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For COLUMNS - GROUND FLOOR | Cum | 11633.1 | 11633.1 | 30.74 | False | None | None | False | None | False | 357601.494 | 0 |
4097313 | 159620 | None | code15 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For LIFT WALL | Cum | 7527.3 | 7527.3 | 3.62 | False | None | None | False | None | False | 27248.826 | 0 |
4097314 | 159620 | None | code16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For COLUMNS - FIRST FLOOR | Cum | 11749.43 | 11749.43 | 26.93 | False | None | None | False | None | False | 316412.1499 | 0 |
4097315 | 159620 | None | code17 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For COLUMNS - SECOND FLOOR | Cum | 11865.76 | 11865.76 | 26.93 | False | None | None | False | None | False | 319544.9168 | 0 |
4097316 | 159620 | None | code18 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For COLUMNS - THIRD FLOOR | Cum | 11982.09 | 11982.09 | 26.93 | False | None | None | False | None | False | 322677.6837 | 0 |
4097317 | 159620 | None | code19 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For COLUMNS - FOURTH FLOOR | Cum | 12098.42 | 12098.42 | 26.93 | False | None | None | False | None | False | 325810.4506 | 0 |
4097318 | 159620 | None | code20 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For COLUMNS - TERRACE FLOOR | Cum | 12214.76 | 12214.76 | 11.57 | False | None | None | False | None | False | 141324.7732 | 0 |
4097319 | 159620 | None | code21 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Plinth Beams, Roof Slab, Staircase - GROUND FLOOR | Cum | 10264.5 | 10264.5 | 147.05 | False | None | None | False | None | False | 1509394.725 | 0 |
4097320 | 159620 | None | code22 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Beams, Roof Beams,Lintel Beams and Cill - GROUND FLOOR | Cum | 10948.8 | 10948.8 | 32.57 | False | None | None | False | None | False | 356602.416 | 0 |
4097321 | 159620 | None | code23 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Roof Beams,Lintel Beams and Cill - FIRST FLOOR | Cum | 11058.29 | 11058.29 | 31.34 | False | None | None | False | None | False | 346566.8086 | 0 |
4097322 | 159620 | None | code24 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Roof Beams,Lintel Beams and Cill - SECOND FLOOR | Cum | 11167.78 | 11167.78 | 31.34 | False | None | None | False | None | False | 349998.2252 | 0 |
4097323 | 159620 | None | code25 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Roof Beams,Lintel Beams and Cill - THIRD FLOOR | Cum | 11277.26 | 11277.26 | 31.24 | False | None | None | False | None | False | 352301.6024 | 0 |
4097324 | 159620 | None | code26 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Roof Beams,Lintel Beams and Cill - FOURTH FLOOR | Cum | 11386.75 | 11386.75 | 31.24 | False | None | None | False | None | False | 355722.07 | 0 |
4097325 | 159620 | None | code27 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Roof beams,Lintel Beams and Cill - TERRACE FLOOR | Cum | 11496.24 | 11496.24 | 7.79 | False | None | None | False | None | False | 89555.7096 | 0 |
4097326 | 159620 | None | code28 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Roof slab & stair case - FIRST FLOOR | Cum | 10367.15 | 10367.15 | 88.09 | False | None | None | False | None | False | 913242.2435 | 0 |
4097327 | 159620 | None | code29 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Roof slab & stair case - SECOND FLOOR | Cum | 10469.79 | 10469.79 | 87.19 | False | None | None | False | None | False | 912860.9901 | 0 |
4097328 | 159620 | None | code30 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Roof slab & stair case- THIRD FLOOR | Cum | 10572.44 | 10572.44 | 87.19 | False | None | None | False | None | False | 921811.0436 | 0 |
4097329 | 159620 | None | code31 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Roof slab & stair case - FOURTH FLOOR | Cum | 10675.08 | 10675.08 | 87.19 | False | None | None | False | None | False | 930760.2252 | 0 |
4097330 | 159620 | None | code32 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Roof slab & stair case - TERRACE FLOOR | Cum | 10777.73 | 10777.73 | 11.57 | False | None | None | False | None | False | 124698.3361 | 0 |
4097331 | 159620 | None | code33 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Chejja - GROUND FLOOR | Cum | 9922.35 | 9922.35 | 2.11 | False | None | None | False | None | False | 20936.1585 | 0 |
4097332 | 159620 | None | code34 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Chejja - FIRST FLOOR | Cum | 10021.57 | 10021.57 | 2.74 | False | None | None | False | None | False | 27459.1018 | 0 |
4097333 | 159620 | None | code35 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Chejja - SECOND FLOOR | Cum | 10120.8 | 10120.8 | 2.74 | False | None | None | False | None | False | 27730.992 | 0 |
4097334 | 159620 | None | code36 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Chejja - THIRD FLOOR | Cum | 10220.02 | 10220.02 | 2.74 | False | None | None | False | None | False | 28002.8548 | 0 |
4097335 | 159620 | None | code37 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Chejja - FOURTH FLOOR | Cum | 10319.24 | 10319.24 | 2.74 | False | None | None | False | None | False | 28274.7176 | 0 |
4097336 | 159620 | None | code38 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Chejja - TERRACE FLOOR | Cum | 10418.47 | 10418.47 | 0.2 | False | None | None | False | None | False | 2083.694 | 0 |
4097337 | 159620 | None | code39 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings - GROUND FLOOR | Tonne | 89457.0 | 89457.0 | 53.68 | False | None | None | False | None | False | 4802051.76 | 0 |
4097338 | 159620 | None | code40 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings - FIRST FLOOR | Tonne | 90351.57 | 90351.57 | 16.41 | False | None | None | False | None | False | 1482669.2637 | 0 |
4097339 | 159620 | None | code41 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings - SECOND FLOOR | Tonne | 91246.14 | 91246.14 | 16.31 | False | None | None | False | None | False | 1488224.5434 | 0 |
4097340 | 159620 | None | code42 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings - THIRD FLOOR | Tonne | 92140.71 | 92140.71 | 16.31 | False | None | None | False | None | False | 1502814.9801 | 0 |
4097341 | 159620 | None | code43 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings - FOURTH FLOOR | Tonne | 93035.28 | 93035.28 | 16.3 | False | None | None | False | None | False | 1516475.064 | 0 |
4097342 | 159620 | None | code44 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings - TERRACE FLOOR | Tonne | 93929.85 | 93929.85 | 3.82 | False | None | None | False | None | False | 358812.027 | 0 |
4097343 | 159620 | None | code45 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 266.0 | 266.0 | 810.29 | False | None | None | False | None | False | 215537.14 | 0 |
4097344 | 159620 | None | code46 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 433.0 | 433.0 | 625.75 | False | None | None | False | None | False | 270949.75 | 0 |
4097345 | 159620 | None | code47 | Loading and Unloading of Stone Boulder /Stone aggregates /Sand /Kankar /Moorum. (Tipper 14 m3) - Taking output 10 t load and lead 10 km = 100 km | Cum | 105.2 | 105.2 | 318.27 | False | None | None | False | None | False | 33482.004 | 0 |
4097346 | 159620 | None | code48 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6389.0 | 6389.0 | 83.09 | False | None | None | False | None | False | 530862.01 | 0 |
4097347 | 159620 | None | code49 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - GROUND FLOOR | Sqm | 1310.0 | 1310.0 | 304.54 | False | None | None | False | None | False | 398947.4 | 0 |
4097348 | 159620 | None | code50 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - FIRST FLOOR | Sqm | 1323.1 | 1323.1 | 326.67 | False | None | None | False | None | False | 432217.077 | 0 |
4097349 | 159620 | None | code51 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - SECOND FLOOR | Sqm | 1336.2 | 1336.2 | 326.67 | False | None | None | False | None | False | 436496.454 | 0 |
4097350 | 159620 | None | code52 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - THIRD FLOOR | Sqm | 1349.3 | 1349.3 | 326.67 | False | None | None | False | None | False | 440775.831 | 0 |
4097351 | 159620 | None | code53 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - FOURTH FLOOR | Sqm | 1362.4 | 1362.4 | 326.67 | False | None | None | False | None | False | 445055.208 | 0 |
4097352 | 159620 | None | code54 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - TERRACE FLOOR | Sqm | 1375.5 | 1375.5 | 209.44 | False | None | None | False | None | False | 288084.72 | 0 |
4097353 | 159620 | None | code55 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - GROUND FLOOR | Sqm | 1231.0 | 1231.0 | 278.45 | False | None | None | False | None | False | 342771.95 | 0 |
4097354 | 159620 | None | code56 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - FIRST FLOOR | Sqm | 1243.31 | 1243.31 | 261.95 | False | None | None | False | None | False | 325685.0545 | 0 |
4097355 | 159620 | None | code57 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - SECOND FLOOR | Cum | 1255.62 | 1255.62 | 261.95 | False | None | None | False | None | False | 328909.659 | 0 |
4097356 | 159620 | None | code58 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - THIRD FLOOR | Sqm | 1267.93 | 1267.93 | 261.95 | False | None | None | False | None | False | 332134.2635 | 0 |
4097357 | 159620 | None | code59 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - FOURTH FLOOR | Sqm | 1280.24 | 1280.24 | 261.95 | False | None | None | False | None | False | 335358.868 | 0 |
4097358 | 159620 | None | code60 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - GROUND FLOOR | Sqm | 1104.0 | 1104.0 | 9.27 | False | None | None | False | None | False | 10234.08 | 0 |
4097359 | 159620 | None | code61 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - FIRST FLOOR | Sqm | 1115.04 | 1115.04 | 112.63 | False | None | None | False | None | False | 125586.9552 | 0 |
4097360 | 159620 | None | code62 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - SECOND FLOOR | Cum | 1126.08 | 1126.08 | 112.63 | False | None | None | False | None | False | 126830.3904 | 0 |
4097361 | 159620 | None | code63 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - THIRD FLOOR | Sqm | 1137.12 | 1137.12 | 112.63 | False | None | None | False | None | False | 128073.8256 | 0 |
4097362 | 159620 | None | code64 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - FOURTH FLOOR | Sqm | 1148.16 | 1148.16 | 112.63 | False | None | None | False | None | False | 129317.2608 | 0 |
4097363 | 159620 | None | code65 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering - GROUND FLOOR | Sqm | 255.0 | 255.0 | 663.51 | False | None | None | False | None | False | 169195.05 | 0 |
4097364 | 159620 | None | code66 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering - FIRST FLOOR | Sqm | 257.55 | 257.55 | 465.09 | False | None | None | False | None | False | 119783.9295 | 0 |
4097365 | 159620 | None | code67 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering - SECOND FLOOR | Sqm | 260.1 | 260.1 | 465.09 | False | None | None | False | None | False | 120969.909 | 0 |
4097366 | 159620 | None | code68 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering - THIRD FLOOR | Sqm | 262.65 | 262.65 | 465.09 | False | None | None | False | None | False | 122155.8885 | 0 |
4097367 | 159620 | None | code69 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering - FOURTH FLOOR | Sqm | 265.2 | 265.2 | 465.09 | False | None | None | False | None | False | 123341.868 | 0 |
4097368 | 159620 | None | code70 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering - TERRACE FLOOR | Sqm | 267.75 | 267.75 | 21.68 | False | None | None | False | None | False | 5804.82 | 0 |
4097369 | 159620 | None | code71 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Wall Plastering - GROUND FLOOR | Sqm | 349.0 | 349.0 | 1209.37 | False | None | None | False | None | False | 422070.13 | 0 |
4097370 | 159620 | None | code72 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Wall Plastering - FIRST FLOOR | Sqm | 352.49 | 352.49 | 1583.05 | False | None | None | False | None | False | 558009.2945 | 0 |
4097371 | 159620 | None | code73 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Wall Plastering - SECOND FLOOR | Sqm | 355.98 | 355.98 | 1583.05 | False | None | None | False | None | False | 563534.139 | 0 |
4097372 | 159620 | None | code74 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Wall Plastering - THIRD FLOOR | Sqm | 359.47 | 359.47 | 1583.05 | False | None | None | False | None | False | 569058.9835 | 0 |
4097373 | 159620 | None | code75 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Wall Plastering - FOURTH FLOOR | Sqm | 362.96 | 362.96 | 1583.05 | False | None | None | False | None | False | 574583.828 | 0 |
4097374 | 159620 | None | code76 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Wall Plastering - TERRACE FLOOR | Sqm | 366.45 | 366.45 | 78.96 | False | None | None | False | None | False | 28934.892 | 0 |
4097375 | 159620 | None | code77 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering - GROUND FLOOR | Sqm | 371.0 | 371.0 | 720.78 | False | None | None | False | None | False | 267409.38 | 0 |
4097376 | 159620 | None | code78 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering - FIRST FLOOR | Sqm | 374.71 | 374.71 | 476.89 | False | None | None | False | None | False | 178695.4519 | 0 |
4097377 | 159620 | None | code79 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering - SECOND FLOOR | Sqm | 378.42 | 378.42 | 476.89 | False | None | None | False | None | False | 180464.7138 | 0 |
4097378 | 159620 | None | code80 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering - THIRD FLOOR | Sqm | 382.13 | 382.13 | 476.89 | False | None | None | False | None | False | 182233.9757 | 0 |
4097379 | 159620 | None | code81 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering - FOURTH FLOOR | Sqm | 385.84 | 385.84 | 476.89 | False | None | None | False | None | False | 184003.2376 | 0 |
4097380 | 159620 | None | code82 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering - TERRACE FLOOR | Sqm | 389.55 | 389.55 | 377.17 | False | None | None | False | None | False | 146926.5735 | 0 |
4097381 | 159620 | None | code83 | KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS - GROUND FLOOR | m | 33.0 | 33.0 | 74.4 | False | None | None | False | None | False | 2455.2 | 0 |
4097382 | 159620 | None | code84 | KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS - FIRST FLOOR | m | 33.33 | 33.33 | 87.4 | False | None | None | False | None | False | 2913.042 | 0 |
4097383 | 159620 | None | code85 | KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS - SECOND FLOOR | m | 33.66 | 33.66 | 87.4 | False | None | None | False | None | False | 2941.884 | 0 |
4097384 | 159620 | None | code86 | KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS - THIRD FLOOR | m | 33.99 | 33.99 | 87.4 | False | None | None | False | None | False | 2970.726 | 0 |
4097385 | 159620 | None | code87 | KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS - FOURTH FLOOR | m | 34.32 | 34.32 | 87.4 | False | None | None | False | None | False | 2999.568 | 0 |
4097386 | 159620 | None | code88 | KSRB 15.8 : Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) - KSRB 15.8.1 do suitable plaster mesh 100mm wide - GROUND FLOOR | m | 26.0 | 26.0 | 850.0 | False | None | None | False | None | False | 22100.0 | 0 |
4097387 | 159620 | None | code89 | KSRB 15.8 : Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) - KSRB 15.8.1 do suitable plaster mesh 100mm wide - FIRST FLOOR | m | 26.26 | 26.26 | 1300.0 | False | None | None | False | None | False | 34138.0 | 0 |
4097388 | 159620 | None | code90 | KSRB 15.8 : Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) - KSRB 15.8.1 do suitable plaster mesh 100mm wide- SECOND FLOOR | m | 26.52 | 26.52 | 1300.0 | False | None | None | False | None | False | 34476.0 | 0 |
4097389 | 159620 | None | code91 | KSRB 15.8 : Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) - KSRB 15.8.1 do suitable plaster mesh 100mm wide - THIRD FLOOR | m | 26.78 | 26.78 | 1300.0 | False | None | None | False | None | False | 34814.0 | 0 |
4097390 | 159620 | None | code92 | KSRB 15.8 : Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) - KSRB 15.8.1 do suitable plaster mesh 100mm wide - FOURTH FLOOR | m | 27.04 | 27.04 | 1300.0 | False | None | None | False | None | False | 35152.0 | 0 |
4097391 | 159620 | None | code93 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Size of Tile 600x600 mm - GROUND FLOOR | Sqm | 1145.0 | 1145.0 | 81.53 | False | None | None | False | None | False | 93351.85 | 0 |
4097392 | 159620 | None | code94 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Size of Tile 600x600 mm - FIRST FLOOR | Sqm | 1156.45 | 1156.45 | 321.8 | False | None | None | False | None | False | 372145.61 | 0 |
4097393 | 159620 | None | code95 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Size of Tile 600x600 mm - SECOND FLOOR | Sqm | 1167.9 | 1167.9 | 321.8 | False | None | None | False | None | False | 375830.22 | 0 |
4097394 | 159620 | None | code96 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Size of Tile 600x600 mm - THIRD FLOOR | Sqm | 1179.35 | 1179.35 | 321.8 | False | None | None | False | None | False | 379514.83 | 0 |
4097395 | 159620 | None | code97 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Size of Tile 600x600 mm - FOURTH FLOOR | Sqm | 1190.8 | 1190.8 | 321.8 | False | None | None | False | None | False | 383199.44 | 0 |
4097396 | 159620 | None | code98 | Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. - GROUND FLOOR | Sqm | 2085.0 | 2085.0 | 460.23 | False | None | None | False | None | False | 959579.55 | 0 |
4097397 | 159620 | None | code99 | Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. - FIRST FLOOR | Sqm | 2105.85 | 2105.85 | 94.86 | False | None | None | False | None | False | 199760.931 | 0 |
4097398 | 159620 | None | code100 | Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. - SECOND FLOOR | Sqm | 2126.7 | 2126.7 | 94.86 | False | None | None | False | None | False | 201738.762 | 0 |
4097399 | 159620 | None | code101 | Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. - THIRD FLOOR | Sqm | 2147.55 | 2147.55 | 94.86 | False | None | None | False | None | False | 203716.593 | 0 |
4097400 | 159620 | None | code102 | Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. - FOURTH FLOOR | Sqm | 2168.4 | 2168.4 | 94.86 | False | None | None | False | None | False | 205694.424 | 0 |
4097401 | 159620 | None | code103 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. - GROUND FLOOR | Sqm | 5328.0 | 5328.0 | 34.23 | False | None | None | False | None | False | 182377.44 | 0 |
4097402 | 159620 | None | code104 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. - FIRST FLOOR | Sqm | 5381.28 | 5381.28 | 23.39 | False | None | None | False | None | False | 125868.1392 | 0 |
4097403 | 159620 | None | code105 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. - SECOND FLOOR | Sqm | 5434.56 | 5434.56 | 23.39 | False | None | None | False | None | False | 127114.3584 | 0 |
4097404 | 159620 | None | code106 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. - THIRD FLOOR | Sqm | 5487.84 | 5487.84 | 23.39 | False | None | None | False | None | False | 128360.5776 | 0 |
4097405 | 159620 | None | code107 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. - FOURTH FLOOR | Sqm | 5541.12 | 5541.12 | 23.39 | False | None | None | False | None | False | 129606.7968 | 0 |
4097406 | 159620 | None | code108 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. - GROUND FLOOR | Sqm | 889.0 | 889.0 | 7.91 | False | None | None | False | None | False | 7031.99 | 0 |
4097407 | 159620 | None | code109 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. - FIRST FLOOR | Sqm | 897.89 | 897.89 | 74.51 | False | None | None | False | None | False | 66901.7839 | 0 |
4097408 | 159620 | None | code110 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. - SECOND FLOOR | Sqm | 906.78 | 906.78 | 74.51 | False | None | None | False | None | False | 67564.1778 | 0 |
4097409 | 159620 | None | code111 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. - THIRD FLOOR | Sqm | 915.67 | 915.67 | 74.51 | False | None | None | False | None | False | 68226.5717 | 0 |
4097410 | 159620 | None | code112 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. - FOURTH FLOOR | Sqm | 924.56 | 924.56 | 74.51 | False | None | None | False | None | False | 68888.9656 | 0 |
4097411 | 159620 | None | code113 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. - GROUND FLOOR | Sqm | 1449.0 | 1449.0 | 59.33 | False | None | None | False | None | False | 85969.17 | 0 |
4097412 | 159620 | None | code114 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. - FIRST FLOOR | Sqm | 1463.49 | 1463.49 | 204.11 | False | None | None | False | None | False | 298712.9439 | 0 |
4097413 | 159620 | None | code115 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. - SECOND FLOOR | Sqm | 1477.98 | 1477.98 | 204.11 | False | None | None | False | None | False | 301670.4978 | 0 |
4097414 | 159620 | None | code116 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. - THIRD FLOOR | Sqm | 1492.47 | 1492.47 | 204.11 | False | None | None | False | None | False | 304628.0517 | 0 |
4097415 | 159620 | None | code117 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. - FOURTH FLOOR | Sqm | 1506.96 | 1506.96 | 204.11 | False | None | None | False | None | False | 307585.6056 | 0 |
4097416 | 159620 | None | code118 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - GROUND FLOOR | Cum | 99600.0 | 99600.0 | 5.37 | False | None | None | False | None | False | 534852.0 | 0 |
4097417 | 159620 | None | code119 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - FIRST FLOOR | Cum | 100596.0 | 100596.0 | 0.89 | False | None | None | False | None | False | 89530.44 | 0 |
4097418 | 159620 | None | code120 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - SECOND FLOOR | Cum | 101592.0 | 101592.0 | 0.89 | False | None | None | False | None | False | 90416.88 | 0 |
4097419 | 159620 | None | code121 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - THIRD FLOOR | Cum | 102588.0 | 102588.0 | 0.89 | False | None | None | False | None | False | 91303.32 | 0 |
4097420 | 159620 | None | code122 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - FOURTH FLOOR | Cum | 103584.0 | 103584.0 | 0.89 | False | None | None | False | None | False | 92189.76 | 0 |
4097421 | 159620 | None | code123 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - TERRACE FLOOR | Cum | 104580.0 | 104580.0 | 0.08 | False | None | None | False | None | False | 8366.4 | 0 |
4097422 | 159620 | None | code124 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - GROUND FLOOR | No | 1016.0 | 1016.0 | 10.0 | False | None | None | False | None | False | 10160.0 | 0 |
4097423 | 159620 | None | code125 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - FIRST FLOOR | No | 1026.16 | 1026.16 | 13.0 | False | None | None | False | None | False | 13340.08 | 0 |
4097424 | 159620 | None | code126 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - SECOND FLOOR | No | 1036.32 | 1036.32 | 13.0 | False | None | None | False | None | False | 13472.16 | 0 |
4097425 | 159620 | None | code127 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - THIRD FLOOR | No | 1046.48 | 1046.48 | 13.0 | False | None | None | False | None | False | 13604.24 | 0 |
4097426 | 159620 | None | code128 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - FOURTH FLOOR | No | 1056.64 | 1056.64 | 13.0 | False | None | None | False | None | False | 13736.32 | 0 |
4097427 | 159620 | None | code129 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - TERRACE FLOOR | No | 1066.8 | 1066.8 | 1.0 | False | None | None | False | None | False | 1066.8 | 0 |
4097428 | 159620 | None | code130 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - GROUND FLOOR | Sqm | 3005.0 | 3005.0 | 19.68 | False | None | None | False | None | False | 59138.4 | 0 |
4097429 | 159620 | None | code131 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - FIRST FLOOR | Sqm | 3035.05 | 3035.05 | 27.3 | False | None | None | False | None | False | 82856.865 | 0 |
4097430 | 159620 | None | code132 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - SECOND FLOOR | Sqm | 3065.1 | 3065.1 | 27.3 | False | None | None | False | None | False | 83677.23 | 0 |
4097431 | 159620 | None | code133 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - THIRD FLOOR | Sqm | 3095.15 | 3095.15 | 27.3 | False | None | None | False | None | False | 84497.595 | 0 |
4097432 | 159620 | None | code134 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - FOURTH FLOOR | Sqm | 3125.2 | 3125.2 | 27.3 | False | None | None | False | None | False | 85317.96 | 0 |
4097433 | 159620 | None | code135 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - TERRACE FLOOR | Sqm | 3155.25 | 3155.25 | 2.52 | False | None | None | False | None | False | 7951.23 | 0 |
4097434 | 159620 | None | code136 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) | Sqm | 7444.0 | 7444.0 | 12.24 | False | None | None | False | None | False | 91114.56 | 0 |
4097435 | 159620 | None | code137 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately). - Size 62 x 125mm - GROUND FLOOR | m | 764.0 | 764.0 | 9.9 | False | None | None | False | None | False | 7563.6 | 0 |
4097436 | 159620 | None | code138 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately). - Size 62 x 125mm - FIRST FLOOR | m | 771.64 | 771.64 | 99.0 | False | None | None | False | None | False | 76392.36 | 0 |
4097437 | 159620 | None | code139 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately). - Size 62 x 125mm - SECOND FLOOR | m | 779.28 | 779.28 | 99.0 | False | None | None | False | None | False | 77148.72 | 0 |
4097438 | 159620 | None | code140 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately). - Size 62 x 125mm - THIRD FLOOR | m | 786.92 | 786.92 | 99.0 | False | None | None | False | None | False | 77905.08 | 0 |
4097439 | 159620 | None | code141 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately). - Size 62 x 125mm - FOURTH FLOOR | m | 794.56 | 794.56 | 99.0 | False | None | None | False | None | False | 78661.44 | 0 |
4097440 | 159620 | None | code142 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness - GROUND FLOOR | Sqm | 3485.0 | 3485.0 | 3.15 | False | None | None | False | None | False | 10977.75 | 0 |
4097441 | 159620 | None | code143 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness - FIRST FLOOR | Sqm | 3519.85 | 3519.85 | 31.5 | False | None | None | False | None | False | 110875.275 | 0 |
4097442 | 159620 | None | code144 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness - SECOND FLOOR | Sqm | 3554.7 | 3554.7 | 31.5 | False | None | None | False | None | False | 111973.05 | 0 |
4097443 | 159620 | None | code145 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness - THIRD FLOOR | Sqm | 3589.55 | 3589.55 | 31.5 | False | None | None | False | None | False | 113070.825 | 0 |
4097444 | 159620 | None | code146 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness - FOURTH FLOOR | Sqm | 3624.4 | 3624.4 | 31.5 | False | None | None | False | None | False | 114168.6 | 0 |
4097445 | 159620 | None | code147 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - GROUND FLOOR | Sqm | 6734.0 | 6734.0 | 44.78 | False | None | None | False | None | False | 301548.52 | 0 |
4097446 | 159620 | None | code148 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - FIRST FLOOR | Sqm | 6801.34 | 6801.34 | 32.63 | False | None | None | False | None | False | 221927.7242 | 0 |
4097447 | 159620 | None | code149 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - SECOND FLOOR | Sqm | 6868.68 | 6868.68 | 32.63 | False | None | None | False | None | False | 224125.0284 | 0 |
4097448 | 159620 | None | code150 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - THIRD FLOOR | Sqm | 6936.02 | 6936.02 | 32.63 | False | None | None | False | None | False | 226322.3326 | 0 |
4097449 | 159620 | None | code151 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - FOURTH FLOOR | Sqm | 7003.36 | 7003.36 | 32.63 | False | None | None | False | None | False | 228519.6368 | 0 |
4097450 | 159620 | None | code152 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - GROUND FLOOR | Sqm | 5719.0 | 5719.0 | 2.64 | False | None | None | False | None | False | 15098.16 | 0 |
4097451 | 159620 | None | code153 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - FIRST FLOOR | Sqm | 5776.19 | 5776.19 | 27.42 | False | None | None | False | None | False | 158383.1298 | 0 |
4097452 | 159620 | None | code154 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - SECOND FLOOR | Sqm | 5833.38 | 5833.38 | 27.42 | False | None | None | False | None | False | 159951.2796 | 0 |
4097453 | 159620 | None | code155 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - THIRD FLOOR | Sqm | 5890.57 | 5890.57 | 27.42 | False | None | None | False | None | False | 161519.4294 | 0 |
4097454 | 159620 | None | code156 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - FOURTH FLOOR | Sqm | 5947.76 | 5947.76 | 27.42 | False | None | None | False | None | False | 163087.5792 | 0 |
4097455 | 159620 | None | code157 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. - GROUND FLOOR | No | 1052.0 | 1052.0 | 10.0 | False | None | None | False | None | False | 10520.0 | 0 |
4097456 | 159620 | None | code158 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. -FIRST FLOOR | No | 1062.52 | 1062.52 | 13.0 | False | None | None | False | None | False | 13812.76 | 0 |
4097457 | 159620 | None | code159 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. - SECOND FLOOR | No | 1073.04 | 1073.04 | 13.0 | False | None | None | False | None | False | 13949.52 | 0 |
4097458 | 159620 | None | code160 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. -THIRD FLOOR | No | 1083.56 | 1083.56 | 13.0 | False | None | None | False | None | False | 14086.28 | 0 |
4097459 | 159620 | None | code161 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. - FOURTH FLOOR | No | 1094.08 | 1094.08 | 13.0 | False | None | None | False | None | False | 14223.04 | 0 |
4097460 | 159620 | None | code162 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm - GROUND FLOOR | Each | 435.0 | 435.0 | 20.0 | False | None | None | False | None | False | 8700.0 | 0 |
4097461 | 159620 | None | code163 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm - FIRST FLOOR | Each | 439.35 | 439.35 | 26.0 | False | None | None | False | None | False | 11423.1 | 0 |
4097462 | 159620 | None | code164 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm - SECOND FLOOR | Each | 443.7 | 443.7 | 26.0 | False | None | None | False | None | False | 11536.2 | 0 |
4097463 | 159620 | None | code165 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm - THIRD FLOOR | Each | 448.05 | 448.05 | 26.0 | False | None | None | False | None | False | 11649.3 | 0 |
4097464 | 159620 | None | code166 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm - FOURTH FLOOR | Each | 452.4 | 452.4 | 26.0 | False | None | None | False | None | False | 11762.4 | 0 |
4097465 | 159620 | None | code167 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete - GROUND FLOOR | Each | 236.0 | 236.0 | 10.0 | False | None | None | False | None | False | 2360.0 | 0 |
4097466 | 159620 | None | code168 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete - FIRST FLOOR | Each | 238.36 | 238.36 | 13.0 | False | None | None | False | None | False | 3098.68 | 0 |
4097467 | 159620 | None | code169 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete - SECOND FLOOR | Each | 240.72 | 240.72 | 13.0 | False | None | None | False | None | False | 3129.36 | 0 |
4097468 | 159620 | None | code170 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete - THIRD FLOOR | Each | 243.08 | 243.08 | 13.0 | False | None | None | False | None | False | 3160.04 | 0 |
4097469 | 159620 | None | code171 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete - FOURTH FLOOR | Each | 245.44 | 245.44 | 13.0 | False | None | None | False | None | False | 3190.72 | 0 |
4097470 | 159620 | None | code172 | Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm - GROUND FLOOR | Each | 249.0 | 249.0 | 20.0 | False | None | None | False | None | False | 4980.0 | 0 |
4097471 | 159620 | None | code173 | Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm -FIRST FLOOR | Each | 251.49 | 251.49 | 26.0 | False | None | None | False | None | False | 6538.74 | 0 |
4097472 | 159620 | None | code174 | Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm - SECOND FLOOR | Each | 253.98 | 253.98 | 26.0 | False | None | None | False | None | False | 6603.48 | 0 |
4097473 | 159620 | None | code175 | Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm -THIRD FLOOR | Each | 256.47 | 256.47 | 26.0 | False | None | None | False | None | False | 6668.22 | 0 |
4097474 | 159620 | None | code176 | Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm - FOURTH FLOOR | Each | 258.96 | 258.96 | 26.0 | False | None | None | False | None | False | 6732.96 | 0 |
4097475 | 159620 | None | code177 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - GROUND FLOOR | No | 275.0 | 275.0 | 40.0 | False | None | None | False | None | False | 11000.0 | 0 |
4097476 | 159620 | None | code178 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - FIRST FLOOR | No | 277.75 | 277.75 | 52.0 | False | None | None | False | None | False | 14443.0 | 0 |
4097477 | 159620 | None | code179 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - SECOND FLOOR | No | 280.5 | 280.5 | 52.0 | False | None | None | False | None | False | 14586.0 | 0 |
4097478 | 159620 | None | code180 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - THIRD FLOOR | No | 283.25 | 283.25 | 52.0 | False | None | None | False | None | False | 14729.0 | 0 |
4097479 | 159620 | None | code181 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - FOURTH FLOOR | No | 286.0 | 286.0 | 52.0 | False | None | None | False | None | False | 14872.0 | 0 |
4097480 | 159620 | None | code182 | Teak wood beading - GROUND FLOOR | m | 60.0 | 60.0 | 46.8 | False | None | None | False | None | False | 2808.0 | 0 |
4097481 | 159620 | None | code183 | Teak wood beading - FIRST FLOOR | m | 60.6 | 60.6 | 67.6 | False | None | None | False | None | False | 4096.56 | 0 |
4097482 | 159620 | None | code184 | Teak wood beading - SECOND FLOOR | m | 61.2 | 61.2 | 67.6 | False | None | None | False | None | False | 4137.12 | 0 |
4097483 | 159620 | None | code185 | Teak wood beading - THIRD FLOOR | m | 61.8 | 61.8 | 67.6 | False | None | None | False | None | False | 4177.68 | 0 |
4097484 | 159620 | None | code186 | Teak wood beading - FOURTH FLOOR | m | 62.4 | 62.4 | 67.6 | False | None | None | False | None | False | 4218.24 | 0 |
4097485 | 159620 | None | code187 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - GROUND FLOOR | Kg | 183.0 | 183.0 | 853.47 | False | None | None | False | None | False | 156185.01 | 0 |
4097486 | 159620 | None | code188 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - FIRST FLOOR | Kg | 184.83 | 184.83 | 1240.65 | False | None | None | False | None | False | 229309.3395 | 0 |
4097487 | 159620 | None | code189 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - SECOND FLOOR | Kg | 186.66 | 186.66 | 1240.65 | False | None | None | False | None | False | 231579.729 | 0 |
4097488 | 159620 | None | code190 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - THIRD FLOOR | Kg | 188.49 | 188.49 | 1240.65 | False | None | None | False | None | False | 233850.1185 | 0 |
4097489 | 159620 | None | code191 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - FOURTH FLOOR | Kg | 190.32 | 190.32 | 1240.65 | False | None | None | False | None | False | 236120.508 | 0 |
4097490 | 159620 | None | code192 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - TERRACE FLOOR | Kg | 192.22 | 192.22 | 22.5 | False | None | None | False | None | False | 4324.95 | 0 |
4097491 | 159620 | None | code193 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. - GROUND FLOOR | Kg | 565.0 | 565.0 | 254.4 | False | None | None | False | None | False | 143736.0 | 0 |
4097492 | 159620 | None | code194 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. - FIRST FLOOR | Kg | 570.65 | 570.65 | 106.78 | False | None | None | False | None | False | 60934.007 | 0 |
4097493 | 159620 | None | code195 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. - SECOND FLOOR | Kg | 576.3 | 576.3 | 106.78 | False | None | None | False | None | False | 61537.314 | 0 |
4097494 | 159620 | None | code196 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. - THIRD FLOOR | Kg | 581.95 | 581.95 | 106.78 | False | None | None | False | None | False | 62140.621 | 0 |
4097495 | 159620 | None | code197 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. - FOURTH FLOOR | Kg | 587.6 | 587.6 | 106.78 | False | None | None | False | None | False | 62743.928 | 0 |
4097496 | 159620 | None | code198 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - GROUND FLOOR | Sqm | 279.0 | 279.0 | 31.08 | False | None | None | False | None | False | 8671.32 | 0 |
4097497 | 159620 | None | code199 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - FIRST FLOOR | Sqm | 281.79 | 281.79 | 213.78 | False | None | None | False | None | False | 60241.0662 | 0 |
4097498 | 159620 | None | code200 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - SECOND FLOOR | Sqm | 284.58 | 284.58 | 213.78 | False | None | None | False | None | False | 60837.5124 | 0 |
4097499 | 159620 | None | code201 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - THIRD FLOOR | Sqm | 287.37 | 287.37 | 213.78 | False | None | None | False | None | False | 61433.9586 | 0 |
4097500 | 159620 | None | code202 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.- FOURTH FLOOR | Sqm | 290.16 | 290.16 | 213.78 | False | None | None | False | None | False | 62030.4048 | 0 |
4097501 | 159620 | None | code203 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - GROUND FLOOR | Sqm | 100.0 | 100.0 | 1853.39 | False | None | None | False | None | False | 185339.0 | 0 |
4097502 | 159620 | None | code204 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - FIRST FLOOR | Sqm | 101.0 | 101.0 | 2048.14 | False | None | None | False | None | False | 206862.14 | 0 |
4097503 | 159620 | None | code205 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - SECOND FLOOR | Sqm | 102.0 | 102.0 | 2048.14 | False | None | None | False | None | False | 208910.28 | 0 |
4097504 | 159620 | None | code206 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - THIRD FLOOR | Sqm | 103.0 | 103.0 | 2048.14 | False | None | None | False | None | False | 210958.42 | 0 |
4097505 | 159620 | None | code207 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - FOURTH FLOOR | Sqm | 104.0 | 104.0 | 2048.14 | False | None | None | False | None | False | 213006.56 | 0 |
4097506 | 159620 | None | code208 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - TERRACE FLOOR | Sqm | 105.0 | 105.0 | 100.64 | False | None | None | False | None | False | 10567.2 | 0 |
4097507 | 159620 | None | code209 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - GROUND FLOOR | Sqm | 180.0 | 180.0 | 1853.39 | False | None | None | False | None | False | 333610.2 | 0 |
4097508 | 159620 | None | code210 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - FIRST FLOOR | Sqm | 181.8 | 181.8 | 2048.14 | False | None | None | False | None | False | 372351.852 | 0 |
4097509 | 159620 | None | code211 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -SECOND FLOOR | Sqm | 183.6 | 183.6 | 2048.14 | False | None | None | False | None | False | 376038.504 | 0 |
4097510 | 159620 | None | code212 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -THIRD FLOOR | Sqm | 185.4 | 185.4 | 2048.14 | False | None | None | False | None | False | 379725.156 | 0 |
4097511 | 159620 | None | code213 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - FOURTH FLOOR | Sqm | 187.2 | 187.2 | 2048.14 | False | None | None | False | None | False | 383411.808 | 0 |
4097512 | 159620 | None | code214 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -TERRACE FLOOR | Sqm | 189.0 | 189.0 | 100.64 | False | None | None | False | None | False | 19020.96 | 0 |
4097513 | 159620 | None | code215 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - GROUND FLOOR | Sqm | 178.0 | 178.0 | 677.52 | False | None | None | False | None | False | 120598.56 | 0 |
4097514 | 159620 | None | code216 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - FIRST FLOOR | Sqm | 179.78 | 179.78 | 476.89 | False | None | None | False | None | False | 85735.2842 | 0 |
4097515 | 159620 | None | code217 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - SECOND FLOOR | Sqm | 181.56 | 181.56 | 476.89 | False | None | None | False | None | False | 86584.1484 | 0 |
4097516 | 159620 | None | code218 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - THIRD FLOOR | Sqm | 183.34 | 183.34 | 476.89 | False | None | None | False | None | False | 87433.0126 | 0 |
4097517 | 159620 | None | code219 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - FOURTH FLOOR | Sqm | 185.12 | 185.12 | 476.89 | False | None | None | False | None | False | 88281.8768 | 0 |
4097518 | 159620 | None | code220 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - TERRACE FLOOR | Sqm | 186.9 | 186.9 | 377.17 | False | None | None | False | None | False | 70493.073 | 0 |
4097519 | 159620 | None | code221 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - GROUND FLOOR | Sqm | 167.0 | 167.0 | 217.95 | False | None | None | False | None | False | 36397.65 | 0 |
4097520 | 159620 | None | code222 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - FIRST FLOOR | Sqm | 168.67 | 168.67 | 137.75 | False | None | None | False | None | False | 23234.2925 | 0 |
4097521 | 159620 | None | code223 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -SECOND FLOOR | Sqm | 170.34 | 170.34 | 137.75 | False | None | None | False | None | False | 23464.335 | 0 |
4097522 | 159620 | None | code224 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. -THIRD FLOOR | Sqm | 172.01 | 172.01 | 137.75 | False | None | None | False | None | False | 23694.3775 | 0 |
4097523 | 159620 | None | code225 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - FOURTH FLOOR | Sqm | 173.68 | 173.68 | 137.75 | False | None | None | False | None | False | 23924.42 | 0 |
4097524 | 159620 | None | code226 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -TERRACE FLOOR | Sqm | 175.35 | 175.35 | 7.3 | False | None | None | False | None | False | 1280.055 | 0 |
4097525 | 159620 | None | code227 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - GROUND FLOOR | Cum | 6287.0 | 6287.0 | 1.78 | False | None | None | False | None | False | 11190.86 | 0 |
4097526 | 159620 | None | code228 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - FIRST FLOOR | Cum | 6349.87 | 6349.87 | 7.89 | False | None | None | False | None | False | 50100.4743 | 0 |
4097527 | 159620 | None | code229 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - SECOND FLOOR | Cum | 6412.74 | 6412.74 | 7.89 | False | None | None | False | None | False | 50596.5186 | 0 |
4097528 | 159620 | None | code230 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - THIRD FLOOR | Cum | 6475.61 | 6475.61 | 7.89 | False | None | None | False | None | False | 51092.5629 | 0 |
4097529 | 159620 | None | code231 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - FOURTH FLOOR | Cum | 6538.48 | 6538.48 | 7.89 | False | None | None | False | None | False | 51588.6072 | 0 |
4097530 | 159620 | None | code232 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - TERRACE FLOOR | Cum | 6601.35 | 6601.35 | 42.19 | False | None | None | False | None | False | 278510.9565 | 0 |
4097531 | 159620 | None | code233 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. - FIRST FLOOR | Cum | 2037.17 | 2037.17 | 23.66 | False | None | None | False | None | False | 48199.4422 | 0 |
4097532 | 159620 | None | code234 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. - SECOND FLOOR | Cum | 2057.34 | 2057.34 | 23.66 | False | None | None | False | None | False | 48676.6644 | 0 |
4097533 | 159620 | None | code235 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. - THIRD FLOOR | Cum | 2077.51 | 2077.51 | 23.66 | False | None | None | False | None | False | 49153.8866 | 0 |
4097534 | 159620 | None | code236 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. - FOURTH FLOOR | Cum | 2097.68 | 2097.68 | 23.66 | False | None | None | False | None | False | 49631.1088 | 0 |
4097535 | 159620 | None | code237 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. - TERRACE FLOOR | Cum | 2117.85 | 2117.85 | 3.02 | False | None | None | False | None | False | 6395.907 | 0 |
4097536 | 159620 | None | code238 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. - FIRST FLOOR | Sqm | 825.17 | 825.17 | 134.85 | False | None | None | False | None | False | 111274.1745 | 0 |
4097537 | 159620 | None | code239 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. - SECOND FLOOR | Sqm | 833.34 | 833.34 | 134.85 | False | None | None | False | None | False | 112375.899 | 0 |
4097538 | 159620 | None | code240 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. - THIRD FLOOR | Sqm | 841.51 | 841.51 | 134.85 | False | None | None | False | None | False | 113477.6235 | 0 |
4097539 | 159620 | None | code241 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. - FOURTH FLOOR | Sqm | 849.68 | 849.68 | 134.85 | False | None | None | False | None | False | 114579.348 | 0 |
4097540 | 159620 | None | code242 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. - TERRACE FLOOR | Sqm | 857.85 | 857.85 | 551.93 | False | None | None | False | None | False | 473473.1505 | 0 |
4097541 | 159620 | None | code243 | Providing & applying high strength non shrink free flow grout (confirming to BS 1881-Part 116 : 1983)comprising of blend of portland cement, graded fillars and chemical additives which impart controlled expansion in the plastic state duly minimizing water demand. (Minimum 25mm thickness around the pipe) | No | 245.0 | 245.0 | 125.0 | False | None | None | False | None | False | 30625.0 | 0 |
4097542 | 159620 | None | code244 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. - GROUND FLOOR | Sqm | 4478.0 | 4478.0 | 1.5 | False | None | None | False | None | False | 6717.0 | 0 |
4097543 | 159620 | None | code245 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. - FIRST FLOOR | Sqm | 4522.78 | 4522.78 | 1.5 | False | None | None | False | None | False | 6784.17 | 0 |
4097544 | 159620 | None | code246 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. - SECOND FLOOR | Sqm | 4567.56 | 4567.56 | 1.5 | False | None | None | False | None | False | 6851.34 | 0 |
4097545 | 159620 | None | code247 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. - THIRD FLOOR | Sqm | 4612.34 | 4612.34 | 1.5 | False | None | None | False | None | False | 6918.51 | 0 |
4097546 | 159620 | None | code248 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. - FOURTH FLOOR | Sqm | 4657.12 | 4657.12 | 1.5 | False | None | None | False | None | False | 6985.68 | 0 |
4097547 | 159620 | None | code249 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. - TERRACE FLOOR | Sqm | 4701.9 | 4701.9 | 2.1 | False | None | None | False | None | False | 9873.99 | 0 |
4097548 | 159620 | None | code250 | Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. | Sqm | 451.0 | 451.0 | 199.5 | False | None | None | False | None | False | 89974.5 | 0 |
4097549 | 159620 | None | code251 | Providing and laying flooring with burnt stone slabs 10 cms thick rough chistle dressed on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3, , including cost of materials, mortar, labour, curing complete as per specifications. | Sqm | 2388.0 | 2388.0 | 4.8 | False | None | None | False | None | False | 11462.4 | 0 |
4097550 | 159620 | None | code252 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. | Sqm | 800.0 | 800.0 | 824.77 | False | None | None | False | None | False | 659816.0 | 0 |
4097551 | 159620 | None | code253 | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401, For Grading -V Material | Cum | 2359.0 | 2359.0 | 164.95 | False | None | None | False | None | False | 389117.05 | 0 |
4097552 | 159620 | None | code254 | For elevation Feauters | LS | 250000.0 | 250000.0 | 1.0 | False | None | None | False | None | False | 250000.0 | 0 |
4097553 | 159620 | None | code255 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. - 20 mm nominal dia pipes | m | 379.0 | 379.0 | 256.25 | False | None | None | False | None | False | 97118.75 | 0 |
4097554 | 159620 | None | code256 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. - 25 mm nominal dia pipes | m | 477.0 | 477.0 | 105.2 | False | None | None | False | None | False | 50180.4 | 0 |
4097555 | 159620 | None | code257 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. - 32 mm nominal dia pipes | m | 557.0 | 557.0 | 48.0 | False | None | None | False | None | False | 26736.0 | 0 |
4097556 | 159620 | None | code258 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN 4, 75mm dia. | m | 217.0 | 217.0 | 326.55 | False | None | None | False | None | False | 70861.35 | 0 |
4097557 | 159620 | None | code259 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN 4, 110mm dia. | m | 288.0 | 288.0 | 493.5 | False | None | None | False | None | False | 142128.0 | 0 |
4097558 | 159620 | None | code260 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN 4, 160mm dia. | m | 697.0 | 697.0 | 250.0 | False | None | None | False | None | False | 174250.0 | 0 |
4097559 | 159620 | None | code261 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore | No | 286.0 | 286.0 | 204.0 | False | None | None | False | None | False | 58344.0 | 0 |
4097560 | 159620 | None | code262 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore | No | 305.0 | 305.0 | 31.0 | False | None | None | False | None | False | 9455.0 | 0 |
4097561 | 159620 | None | code263 | Providing and fixing brass stop cock of approved quality : 15 mm nominal bore | No | 299.0 | 299.0 | 204.0 | False | None | None | False | None | False | 60996.0 | 0 |
4097562 | 159620 | None | code264 | Providing and fixing brass stop cock of approved quality : 20 mm nominal bore | No | 305.0 | 305.0 | 31.0 | False | None | None | False | None | False | 9455.0 | 0 |
4097563 | 159620 | None | code265 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. | Each | 14212.0 | 14212.0 | 2.0 | False | None | None | False | None | False | 28424.0 | 0 |
4097564 | 159620 | None | code266 | Providing and fixing Single flow hand showers with Anti lime jets with 1.5m PVC tube and holder made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy | No | 887.0 | 887.0 | 42.0 | False | None | None | False | None | False | 37254.0 | 0 |
4097565 | 159620 | None | code267 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. | No | 3082.0 | 3082.0 | 50.0 | False | None | None | False | None | False | 154100.0 | 0 |
4097566 | 159620 | None | code268 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete - 1 Nahani Trap | Each | 220.0 | 220.0 | 99.0 | False | None | None | False | None | False | 21780.0 | 0 |
4097567 | 159620 | None | code269 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Each | 1220.0 | 1220.0 | 50.0 | False | None | None | False | None | False | 61000.0 | 0 |
4097568 | 159620 | None | code270 | Providing and fixing toilet paper holder : C P Brass | Each | 608.0 | 608.0 | 2.0 | False | None | None | False | None | False | 1216.0 | 0 |
4097569 | 159620 | None | code271 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 02mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. | No | 100.0 | 100.0 | 42.0 | False | None | None | False | None | False | 4200.0 | 0 |
4097570 | 159620 | None | code272 | Supply of PPR Gate valve confirming to IS 15801-2008 and DIN Standards 8077/8092 - PPR Gate valve 20mm | Each | 378.0 | 378.0 | 23.0 | False | None | None | False | None | False | 8694.0 | 0 |
4097571 | 159620 | None | code273 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screwwith concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Each | 496.0 | 496.0 | 42.0 | False | None | None | False | None | False | 20832.0 | 0 |
4097572 | 159620 | None | code274 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. | Each | 5562.0 | 5562.0 | 2.0 | False | None | None | False | None | False | 11124.0 | 0 |
4097573 | 159620 | None | code275 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :100 mm diameter | No | 257.0 | 257.0 | 2.0 | False | None | None | False | None | False | 514.0 | 0 |
4097574 | 159620 | None | code276 | Providing and fixing Stainless Steel Grab Bar 600 mm Long with all concealed fitting arrangements & all necessary accesories complete - Class - b) Premium | No | 8159.0 | 8159.0 | 3.0 | False | None | None | False | None | False | 24477.0 | 0 |
4097575 | 159620 | None | code277 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 4838.0 | 4838.0 | 40.0 | False | None | None | False | None | False | 193520.0 | 0 |
4097576 | 159620 | None | code278 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. Do with - 50 mm nominal dia Pipes | m | 721.0 | 721.0 | 209.2 | False | None | None | False | None | False | 150833.2 | 0 |
4097577 | 159620 | None | code279 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. Do with - 40 mm nominal dia Pipes | m | 477.0 | 477.0 | 202.5 | False | None | None | False | None | False | 96592.5 | 0 |
4097578 | 159620 | None | code280 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. Do with - 32 mm nominal dia Pipes | m | 372.0 | 372.0 | 100.0 | False | None | None | False | None | False | 37200.0 | 0 |
4097579 | 159620 | None | code281 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. Do with - 25 mm nominal dia Pipes | m | 296.0 | 296.0 | 257.0 | False | None | None | False | None | False | 76072.0 | 0 |
4097580 | 159620 | None | code282 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. Do with - 20 mm nominal dia Pipes | m | 217.0 | 217.0 | 47.0 | False | None | None | False | None | False | 10199.0 | 0 |
4097581 | 159620 | None | code283 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark - For 25 mm dia GM (Copper alloy) Gate valves | Each | 1169.0 | 1169.0 | 3.0 | False | None | None | False | None | False | 3507.0 | 0 |
4097582 | 159620 | None | code284 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark - For 32 mm dia GM (Copper alloy) Gate valves | Each | 1338.0 | 1338.0 | 4.0 | False | None | None | False | None | False | 5352.0 | 0 |
4097583 | 159620 | None | code285 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark - For 40 mm dia GM (Copper alloy) Gate valves | Each | 1500.0 | 1500.0 | 4.0 | False | None | None | False | None | False | 6000.0 | 0 |
4097584 | 159620 | None | code286 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark - For 50 mm dia GM (Copper alloy) Gate valves | Each | 1688.0 | 1688.0 | 4.0 | False | None | None | False | None | False | 6752.0 | 0 |
4097585 | 159620 | None | code287 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m | Cum | 262.0 | 262.0 | 244.1 | False | None | None | False | None | False | 63954.2 | 0 |
4097586 | 159620 | None | code288 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | Each | 4236.0 | 4236.0 | 9.0 | False | None | None | False | None | False | 38124.0 | 0 |
4097587 | 159620 | None | code289 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover | Each | 5454.0 | 5454.0 | 13.0 | False | None | None | False | None | False | 70902.0 | 0 |
4097588 | 159620 | None | code290 | Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding. - 300 litres | Each | 69986.0 | 69986.0 | 5.0 | False | None | None | False | None | False | 349930.0 | 0 |
4097589 | 159620 | None | code291 | Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm - Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.5M depth & SFRC Cover & Frame | Each | 41568.0 | 41568.0 | 2.0 | False | None | None | False | None | False | 83136.0 | 0 |
4097590 | 159620 | None | code292 | Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm - Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.2 M depth & SFRC cover | Each | 31370.0 | 31370.0 | 2.0 | False | None | None | False | None | False | 62740.0 | 0 |
4097591 | 159620 | None | code293 | Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5 Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without controls which shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - Short Point up to 3 mtrs from tapping point to outlet via switch | Point | 269.0 | 269.0 | 65.0 | False | None | None | False | None | False | 17485.0 | 0 |
4097592 | 159620 | None | code294 | Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5 Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without controls which shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. - Medium point above 3m upto 6m from tapping point to out let via switch | Point | 379.0 | 379.0 | 130.0 | False | None | None | False | None | False | 49270.0 | 0 |
4097593 | 159620 | None | code295 | Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5 Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without controls which shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. - Long point above 6m upto 10m from tapping point to out let via switch | Point | 555.0 | 555.0 | 60.0 | False | None | None | False | None | False | 33300.0 | 0 |
4097594 | 159620 | None | code296 | Supplying heavy gauge PVC conduit pipe......mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18 SWGGI fish wire wherever necessary - 19/20 mm dia 2 mm thick | m | 66.0 | 66.0 | 2250.0 | False | None | None | False | None | False | 148500.0 | 0 |
4097595 | 159620 | None | code297 | Supplying heavy gauge PVC conduit pipe......mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18 SWGGI fish wire wherever necessary - 25 mm dia 2 mm thick | m | 78.0 | 78.0 | 2800.0 | False | None | None | False | None | False | 218400.0 | 0 |
4097596 | 159620 | None | code298 | Supplying heavy gauge PVC Conduit Pipe.... dia.......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWGGI fish wire run throughout the conduit wherever necessary. - 19/20 mm dia 2 mm thick | m | 68.0 | 68.0 | 1200.0 | False | None | None | False | None | False | 81600.0 | 0 |
4097597 | 159620 | None | code299 | Supplying heavy gauge PVC Conduit Pipe.... dia.......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWGGI fish wire run throughout the conduit wherever necessary. - 25 mm dia 2 mm thick | m | 79.0 | 79.0 | 650.0 | False | None | None | False | None | False | 51350.0 | 0 |
4097598 | 159620 | None | code300 | Supplying and fixing PVC/metal conduit Deep junction box - 19/20 mm deep Junction box | Each | 49.0 | 49.0 | 175.0 | False | None | None | False | None | False | 8575.0 | 0 |
4097599 | 159620 | None | code301 | Supplying and fixing PVC/metal conduit Deep junction box - 25 mm deep Junction box | Each | 56.0 | 56.0 | 80.0 | False | None | None | False | None | False | 4480.0 | 0 |
4097600 | 159620 | None | code302 | Supplying And Fixing Metal Fan Box with Round Hook. | No | 117.0 | 117.0 | 130.0 | False | None | None | False | None | False | 15210.0 | 0 |
4097601 | 159620 | None | code303 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.Cwall: 1-2 Way | Each | 138.0 | 138.0 | 12.0 | False | None | None | False | None | False | 1656.0 | 0 |
4097602 | 159620 | None | code304 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.Cwall: 3 Way | Each | 159.0 | 159.0 | 15.0 | False | None | None | False | None | False | 2385.0 | 0 |
4097603 | 159620 | None | code305 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.Cwall: 4 - 5 Way | Each | 177.0 | 177.0 | 10.0 | False | None | None | False | None | False | 1770.0 | 0 |
4097604 | 159620 | None | code306 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.Cwall: 6 Way | Each | 220.0 | 220.0 | 10.0 | False | None | None | False | None | False | 2200.0 | 0 |
4097605 | 159620 | None | code307 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.Cwall: 8 Way | Each | 261.0 | 261.0 | 104.0 | False | None | None | False | None | False | 27144.0 | 0 |
4097606 | 159620 | None | code308 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.Cwall: 10-12 Way | Each | 319.0 | 319.0 | 12.0 | False | None | None | False | None | False | 3828.0 | 0 |
4097607 | 159620 | None | code309 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.: 1-2 Module | Each | 137.0 | 137.0 | 12.0 | False | None | None | False | None | False | 1644.0 | 0 |
4097608 | 159620 | None | code310 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.: 3 Module | Each | 161.0 | 161.0 | 15.0 | False | None | None | False | None | False | 2415.0 | 0 |
4097609 | 159620 | None | code311 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.: 4 Module | Each | 175.0 | 175.0 | 10.0 | False | None | None | False | None | False | 1750.0 | 0 |
4097610 | 159620 | None | code312 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.: 6 Module | Each | 234.0 | 234.0 | 10.0 | False | None | None | False | None | False | 2340.0 | 0 |
4097611 | 159620 | None | code313 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.: 8 Module | Each | 284.0 | 284.0 | 104.0 | False | None | None | False | None | False | 29536.0 | 0 |
4097612 | 159620 | None | code314 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.: 10-12 Module | Each | 344.0 | 344.0 | 12.0 | False | None | None | False | None | False | 4128.0 | 0 |
4097613 | 159620 | None | code315 | Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 6A One Way Switch | Each | 102.0 | 102.0 | 552.0 | False | None | None | False | None | False | 56304.0 | 0 |
4097614 | 159620 | None | code316 | Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 6A Two Way Switch | Each | 166.0 | 166.0 | 12.0 | False | None | None | False | None | False | 1992.0 | 0 |
4097615 | 159620 | None | code317 | Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 6A Three Way socket | Each | 171.0 | 171.0 | 140.0 | False | None | None | False | None | False | 23940.0 | 0 |
4097616 | 159620 | None | code318 | Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: Stepped Fan Regulator Two Module | Each | 357.0 | 357.0 | 130.0 | False | None | None | False | None | False | 46410.0 | 0 |
4097617 | 159620 | None | code319 | Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 16A One Way Switch | Each | 180.0 | 180.0 | 6.0 | False | None | None | False | None | False | 1080.0 | 0 |
4097618 | 159620 | None | code320 | Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 6A Bell Push | Each | 177.0 | 177.0 | 1.0 | False | None | None | False | None | False | 177.0 | 0 |
4097619 | 159620 | None | code321 | Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 32A DP Switch | Each | 326.0 | 326.0 | 4.0 | False | None | None | False | None | False | 1304.0 | 0 |
4097620 | 159620 | None | code322 | Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 6/16A Universal Socket | Each | 236.0 | 236.0 | 10.0 | False | None | None | False | None | False | 2360.0 | 0 |
4097621 | 159620 | None | code323 | Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: TV/Telephone Socket | Each | 156.0 | 156.0 | 4.0 | False | None | None | False | None | False | 624.0 | 0 |
4097622 | 159620 | None | code324 | Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: RJ45/I.O Outlet Cat-6 | Each | 337.0 | 337.0 | 5.0 | False | None | None | False | None | False | 1685.0 | 0 |
4097623 | 159620 | None | code325 | Supplying and fixing one of 230V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. - Ding Dong Bell | Each | 246.0 | 246.0 | 1.0 | False | None | None | False | None | False | 246.0 | 0 |
4097624 | 159620 | None | code326 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacityMCB's single phase/3 phase/single door with powder coatedpainting Made out of 14 SWG MS enclosure. - III - Double Door, 12 Way SP & N | Each | 2329.0 | 2329.0 | 1.0 | False | None | None | False | None | False | 2329.0 | 0 |
4097625 | 159620 | None | code327 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacityMCB's single phase/3 phase/single door with powder coatedpainting Made out of 14 SWG MS enclosure. - III - Double Door, 6 Way TP & N | Each | 4940.0 | 4940.0 | 5.0 | False | None | None | False | None | False | 24700.0 | 0 |
4097626 | 159620 | None | code328 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.: 32-40A 4 pole | Each | 5147.0 | 5147.0 | 5.0 | False | None | None | False | None | False | 25735.0 | 0 |
4097627 | 159620 | None | code329 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.: 63A 4 pole | Each | 5545.0 | 5545.0 | 1.0 | False | None | None | False | None | False | 5545.0 | 0 |
4097628 | 159620 | None | code330 | Supplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898.: 6-32A SP MCB | Each | 415.0 | 415.0 | 77.0 | False | None | None | False | None | False | 31955.0 | 0 |
4097629 | 159620 | None | code331 | Supplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898.: 6-32A DP MCB | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 |
4097630 | 159620 | None | code332 | Supplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898.: 40A TPN MCB | Each | 3044.0 | 3044.0 | 9.0 | False | None | None | False | None | False | 27396.0 | 0 |
4097631 | 159620 | None | code333 | Supplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898.: 50-63A TPN MCB | Each | 3088.0 | 3088.0 | 2.0 | False | None | None | False | None | False | 6176.0 | 0 |
4097632 | 159620 | None | code334 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010: 1.5 mSqm | m | 26.0 | 26.0 | 3500.0 | False | None | None | False | None | False | 91000.0 | 0 |
4097633 | 159620 | None | code335 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010: 2.5 mSqm | m | 42.0 | 42.0 | 6020.0 | False | None | None | False | None | False | 252840.0 | 0 |
4097634 | 159620 | None | code336 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010: 4.0 mSqm | m | 63.0 | 63.0 | 1200.0 | False | None | None | False | None | False | 75600.0 | 0 |
4097635 | 159620 | None | code337 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010: 6.0 mSqm | m | 92.0 | 92.0 | 200.0 | False | None | None | False | None | False | 18400.0 | 0 |
4097636 | 159620 | None | code338 | Supplying of.....feet PVC Batten with integrated LED tube....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 a long with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.: LED light fitting 1 x 4' - 20/22 W | Each | 690.0 | 690.0 | 190.0 | False | None | None | False | None | False | 131100.0 | 0 |
4097637 | 159620 | None | code339 | Supplying of.....feet PVC Batten with integrated LED tube....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 a long with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.: LED light fitting 1 x 4' - 36/40 W | Each | 1269.0 | 1269.0 | 30.0 | False | None | None | False | None | False | 38070.0 | 0 |
4097638 | 159620 | None | code340 | Fixing all types and all capacities of fluorescent/ false ceiling/ spotlight/ CFL/ LED fittings indoor on the wall/ ceiling/ rafters/ girders using 23/ 0.0076" twint wisted PVC insulated wires, required Nos of round blocks and clamps. - On wall/ ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 220.0 | False | None | None | False | None | False | 26840.0 | 0 |
4097639 | 159620 | None | code341 | Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than80 lumen per W, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should smaller than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. Theoperating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.: 9W, 6500K | Each | 154.0 | 154.0 | 35.0 | False | None | None | False | None | False | 5390.0 | 0 |
4097640 | 159620 | None | code342 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopiesetc, for operation on 230V, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. - 48" Sweep (1200 mm) Regular model | Each | 2984.0 | 2984.0 | 130.0 | False | None | None | False | None | False | 387920.0 | 0 |
4097641 | 159620 | None | code343 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. - Fixing Ceiling Fans | Each | 171.0 | 171.0 | 130.0 | False | None | None | False | None | False | 22230.0 | 0 |
4097642 | 159620 | None | code344 | Supplying of 1440 rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. - 12" Sweep (300 mm) | Each | 2969.0 | 2969.0 | 20.0 | False | None | None | False | None | False | 59380.0 | 0 |
4097643 | 159620 | None | code345 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5A. Ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire. | Each | 492.0 | 492.0 | 20.0 | False | None | None | False | None | False | 9840.0 | 0 |
4097644 | 159620 | None | code346 | Fabrication suppling and mountuing MS box, made out SWG suitable floor / wall mounting , fully weather proof with privision for better heat disspation , provided with hinged front cover, equipped with temper proof locking arrangements , with suitable size clamps with necessary cable entey pipe with gland and box should be finsihed with 7 tanks treatment with powder coated paint and finllay finished with approved colour etc,.. complete. - 16 SWG | Sq CM | 0.43 | 0.43 | 337500.0 | False | None | None | False | None | False | 145125.0 | 0 |
4097645 | 159620 | None | code347 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.: FOUR Pole 100 A 25 kA | Each | 8487.0 | 8487.0 | 1.0 | False | None | None | False | None | False | 8487.0 | 0 |
4097646 | 159620 | None | code348 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.: FOUR Pole 160 A 25 kA | Each | 13447.0 | 13447.0 | 2.0 | False | None | None | False | None | False | 26894.0 | 0 |
4097647 | 159620 | None | code349 | Supplying.........A rated 3 phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/ FRP/ DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete: 250 A 4 x 30 x 10 mm Aluminium Strips | m | 3435.0 | 3435.0 | 28.0 | False | None | None | False | None | False | 96180.0 | 0 |
4097648 | 159620 | None | code350 | Supply and fixing of angle iron frame work fabricated out of ms angle iron,.. With bolts , washer, etc, and painted with 2 coat of red oxide and then two coats of approved paint. - 50 x 100 x 50 x 6 mm C channel | m | 756.0 | 756.0 | 12.0 | False | None | None | False | None | False | 9072.0 | 0 |
4097649 | 159620 | None | code351 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT | Each | 1703.0 | 1703.0 | 1.0 | False | None | None | False | None | False | 1703.0 | 0 |
4097650 | 159620 | None | code352 | Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board. | Each | 452.0 | 452.0 | 1.0 | False | None | None | False | None | False | 452.0 | 0 |
4097651 | 159620 | None | code353 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 515.0 | 515.0 | 6.0 | False | None | None | False | None | False | 3090.0 | 0 |
4097652 | 159620 | None | code354 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50Hz AC with latest micro controller based, digital read out of percentage leakage current, programmable delay/ auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 9255.0 | 9255.0 | 1.0 | False | None | None | False | None | False | 9255.0 | 0 |
4097653 | 159620 | None | code355 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm allround with alterate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.GI pipe earthing make-TATA/GENITH,JINDAL. | No | 4256.0 | 4256.0 | 8.0 | False | None | None | False | None | False | 34048.0 | 0 |
4097654 | 159620 | None | code356 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.: 25 x 3 mm GI strip | m | 82.0 | 82.0 | 150.0 | False | None | None | False | None | False | 12300.0 | 0 |
4097655 | 159620 | None | code357 | Supplying and fixing of LED Bulk head of 10W with IP 65 protection and IK08 impact resistance suitable for surface and wall mounting applications. | Each | 842.0 | 842.0 | 5.0 | False | None | None | False | None | False | 4210.0 | 0 |
4097656 | 159620 | None | code358 | Supplying of on Auto load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution): 200 A | Each | 15249.0 | 15249.0 | 1.0 | False | None | None | False | None | False | 15249.0 | 0 |
4097657 | 159620 | None | code359 | Fixing of..... A TPST / change overs witch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling. - 100A to 250A TPST | Each | 447.0 | 447.0 | 1.0 | False | None | None | False | None | False | 447.0 | 0 |
4097658 | 159620 | None | code360 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975: 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm) | Km | 373215.0 | 373215.0 | 0.25 | False | None | None | False | None | False | 93303.75 | 0 |
4097659 | 159620 | None | code361 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975: 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) | Km | 139549.0 | 139549.0 | 0.25 | False | None | None | False | None | False | 34887.25 | 0 |
4097660 | 159620 | None | code362 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975: 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) | Km | 141842.0 | 141842.0 | 0.05 | False | None | None | False | None | False | 7092.1 | 0 |
4097661 | 159620 | None | code363 | Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable - 3.5 x 70/95/120 Sqmm | Set | 382.0 | 382.0 | 6.0 | False | None | None | False | None | False | 2292.0 | 0 |
4097662 | 159620 | None | code364 | Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable - Up to 4C x 50 Sqmm | Set | 324.0 | 324.0 | 10.0 | False | None | None | False | None | False | 3240.0 | 0 |
4097663 | 159620 | None | code365 | Aluminium End Terminal (Lug) - 95 Sqmm | No | 15.0 | 15.0 | 24.0 | False | None | None | False | None | False | 360.0 | 0 |
4097664 | 159620 | None | code366 | Aluminium End Terminal (Lug) - 25 Sqmm | No | 3.0 | 3.0 | 16.0 | False | None | None | False | None | False | 48.0 | 0 |
4097665 | 159620 | None | code367 | Aluminium End Terminal (Lug) - 16 Sqmm | No | 2.0 | 2.0 | 16.0 | False | None | None | False | None | False | 32.0 | 0 |
4097666 | 159620 | None | code368 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable - 35 to 95 Sqmm | Km | 31139.0 | 31139.0 | 0.25 | False | None | None | False | None | False | 7784.75 | 0 |
4097667 | 159620 | None | code369 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable - 2.5 to 25 Sqmm | Km | 20886.0 | 20886.0 | 0.3 | False | None | None | False | None | False | 6265.8 | 0 |
4097668 | 159620 | None | code370 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. - In all kinds of soils. Depth upto 1.50m | m | 484.0 | 484.0 | 20.0 | False | None | None | False | None | False | 9680.0 | 0 |
4097669 | 159620 | None | code371 | Fabricating, supplying and erection of...ms long hot dip Galvanized Octagonal hot dip Pole with BSEN10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to with stand the wind speed of 47 m/s for.......m Pole in single section and single joint welded as per IS 9595 / IS 10178 AWS having dimensions bottom.....mm, top....mm with 3mm thick, suitable base plate and 4 Nos of..... long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65 micron as per ASTM- A 123 and 153 etc.,(excluding foundation) as per drawing appended. - 9 m - Top 70 mm and Bottom 155 mm dia | Each | 19500.0 | 19500.0 | 1.0 | False | None | None | False | None | False | 19500.0 | 0 |
4097670 | 159620 | None | code372 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4" dia telescopic M.S. pipe, with 2" dia 1.5m long M.S. Bracket and are welded with suitable angle, using 6mm thick M.S.sheet, grip bolts & nuts, as required, suitable for 9 to 12ms. M.S. tubular pole, with necessary two coats of painting, with all other accessories. - Single bracket 1.5 m. Length | No | 1461.0 | 1461.0 | 1.0 | False | None | None | False | None | False | 1461.0 | 0 |
4097671 | 159620 | None | code373 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencygreater than130lm/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. - LED Streetlight 90 W | Each | 8860.0 | 8860.0 | 1.0 | False | None | None | False | None | False | 8860.0 | 0 |
4097672 | 159620 | None | code374 | Fixing halogen / metal halide / SVL / IL / LED flood light fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. | Each | 162.0 | 162.0 | 1.0 | False | None | None | False | None | False | 162.0 | 0 |
4097673 | 159620 | None | code375 | Supplying and drawing Flexible Multi core Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 - 3C x 1.5 mm2 | m | 72.0 | 72.0 | 12.0 | False | None | None | False | None | False | 864.0 | 0 |
4097674 | 159620 | None | code376 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 38.0 | 38.0 | 549.0 | False | None | None | False | None | False | 20862.0 | 0 |
4097675 | 159620 | None | code377 | Supplying & Fixing of ... ms Cat 6 Patch Cable - 2m | Each | 257.0 | 257.0 | 6.0 | False | None | None | False | None | False | 1542.0 | 0 |
4097676 | 159620 | None | code378 | Supplying & Fixing of switch mounting rack with power manager & Cable manager. - 12U with 450mm depth | Each | 8835.0 | 8835.0 | 1.0 | False | None | None | False | None | False | 8835.0 | 0 |
4097677 | 159620 | None | code379 | Supplying & Fixing of Power strip | Each | 1457.0 | 1457.0 | 1.0 | False | None | None | False | None | False | 1457.0 | 0 |
4097678 | 159620 | None | code380 | Supplying fixing of Network Switches: 8 port 10/100 Switch | Each | 1050.0 | 1050.0 | 1.0 | False | None | None | False | None | False | 1050.0 | 0 |
4097679 | 159620 | None | code381 | Supply Installation Testing 32Channel Digital Video Recorder with Video Input, Real Time recording DVR & AV compatible, improved clarity for better recognition, longer recording time, extended range of features, multiple interfacing options, image quality with all required accessories including all labour charges etc complete | Each | 38000.0 | 38000.0 | 1.0 | False | None | None | False | None | False | 38000.0 | 0 |
4097680 | 159620 | None | code382 | Supply & Installation of indoor fixed dome camera with 720TVL ,1/3" Super HAD CCD colour, 3.6mm fixed lens,2 mega picsels, Day & Night IR LED & supports 15Mtr distance, enhanced picture quality, reliability mounted on ceilings or walls with all required accessories including all labour charges etc complete. | Each | 9750.0 | 9750.0 | 10.0 | False | None | None | False | None | False | 97500.0 | 0 |
4097681 | 159620 | None | code383 | Supply & Installation of Outdoor bullet camera with 650TVL,Day & Night IR LED supports 60 Mtr distance, 4 mega piicsels , HD, enhanced picture quality, reliability mounted on ceiling or walls,with IP55 Enclosure with all required steel supports ,accessories including all labour charges etc complete. | Each | 16247.0 | 16247.0 | 4.0 | False | None | None | False | None | False | 64988.0 | 0 |
4097682 | 159620 | None | code384 | DG SETS :Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation Alternator: Alternator is suitable for operation at 1500 RPM, 415 V, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS/IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have+/- 1.0% Voltage regulation (max) in static conditions- IP: 23 protections with insulation class F&H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lA for Load On and Set Running, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections .Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,-Auto start mode accepts a ground signal from remote devices to automatically start the DG set The remote start will also wake up the control system from sleep mode. Engine Starting -The control system supports automatic engine starting, Primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency. Controller provide configurable time delay of 0-300 sees to start after remote start signal and time delay of 0- 600secs prior to shut down after stop signal. Sleep mode increase battery life. Configurable current settings from low to minimize current draw when genset is not working. Engine Protective functions include, Configurable alarm output, (P.No. 42, I.No. 10.1.7, Part-III of Vol-6, PWD Ele SR 2023-24) AS PER KPWD SR specifications | Set | 641071.0 | 641071.0 | 1.0 | False | None | None | False | None | False | 641071.0 | 0 |
4097683 | 159620 | None | code385 | Supply, Erection, testing and commissioning of AMF panel suitable for .....kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules.: 62.5 KVA | Each | 77768.0 | 77768.0 | 1.0 | False | None | None | False | None | False | 77768.0 | 0 |
4097684 | 159620 | None | code386 | Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete. | Each | 5288.0 | 5288.0 | 1.0 | False | None | None | False | None | False | 5288.0 | 0 |
4097685 | 159620 | None | code387 | Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth): Borewell depth of 0 to 50 Mtrs | m | 309.0 | 309.0 | 50.0 | False | None | None | False | None | False | 15450.0 | 0 |
4097686 | 159620 | None | code388 | Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth): Borewell depth of 50 to 100 Mtrs | m | 387.0 | 387.0 | 50.0 | False | None | None | False | None | False | 19350.0 | 0 |
4097687 | 159620 | None | code389 | Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth): Borewell depth of 100 to 150 Mtrs | m | 412.0 | 412.0 | 50.0 | False | None | None | False | None | False | 20600.0 | 0 |
4097688 | 159620 | None | code390 | Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth): Borewell depth of 150 to 200 Mtrs | m | 478.0 | 478.0 | 50.0 | False | None | None | False | None | False | 23900.0 | 0 |
4097689 | 159620 | None | code391 | Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth): Borewell depth of 200 to 250 Mtrs | m | 560.0 | 560.0 | 50.0 | False | None | None | False | None | False | 28000.0 | 0 |
4097690 | 159620 | None | code392 | Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth): Borewell depth of 250 to 300 Mtrs | m | 593.0 | 593.0 | 50.0 | False | None | None | False | None | False | 29650.0 | 0 |
4097691 | 159620 | None | code393 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | m | 1933.0 | 1933.0 | 30.0 | False | None | None | False | None | False | 57990.0 | 0 |
4097692 | 159620 | None | code394 | Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge. | Each | 164.0 | 164.0 | 1.0 | False | None | None | False | None | False | 164.0 | 0 |
4097693 | 159620 | None | code395 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments | Each | 150.0 | 150.0 | 2.0 | False | None | None | False | None | False | 300.0 | 0 |
4097694 | 159620 | None | code396 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. - 7.50 HP - 135 LPM @ 140 m = 12 STG Outlet Dia - 2.00" | Each | 36620.0 | 36620.0 | 1.0 | False | None | None | False | None | False | 36620.0 | 0 |
4097695 | 159620 | None | code397 | Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover). - 50 mm | Each | 3050.0 | 3050.0 | 50.0 | False | None | None | False | None | False | 152500.0 | 0 |
4097696 | 159620 | None | code398 | Labour charges for Erection of new / repaired submersible pump set along with GI pipes (32mm / 50mm), cable (New submersible pump set if required will be supplied by the department free of cost and released pump set should be handed over to department) including transportation (Each length = 6 m) | Each | 187.0 | 187.0 | 50.0 | False | None | None | False | None | False | 9350.0 | 0 |
4097697 | 159620 | None | code399 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. - 1x3x6 Sqm. | m | 185.0 | 185.0 | 330.0 | False | None | None | False | None | False | 61050.0 | 0 |
4097698 | 159620 | None | code400 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments. - Size 50 mm | Each | 1250.0 | 1250.0 | 1.0 | False | None | None | False | None | False | 1250.0 | 0 |
4097699 | 159620 | None | code401 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. - for outdoor - 6 to 15 HP pumps | Each | 17500.0 | 17500.0 | 1.0 | False | None | None | False | None | False | 17500.0 | 0 |
4097700 | 159620 | None | code402 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 - 16 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm) | Km | 88418.0 | 88418.0 | 0.3 | False | None | None | False | None | False | 26525.4 | 0 |
4097701 | 159620 | None | code403 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. In existing trench/duct / 6 sqmm to 16 sqmm | Mtr | 11.88 | 11.88 | 300.0 | False | None | None | False | None | False | 3564.0 | 0 |
4097702 | 159620 | None | code404 | Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV. 65mm | Mtr | 566.0 | 566.0 | 10.0 | False | None | None | False | None | False | 5660.0 | 0 |
4097703 | 159620 | None | code405 | Supplying and fixing L.T. cast Iron pot heads suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps, bolts, nuts and washers etc. 16Sqmm | Each | 270.0 | 270.0 | 1.0 | False | None | None | False | None | False | 270.0 | 0 |
4097704 | 159620 | None | code406 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - UG SUMP | Sqm | 312.0 | 312.0 | 75.1 | False | None | None | False | None | False | 23431.2 | 0 |
4097705 | 159620 | None | code407 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel reinforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) | Sqm | 615.0 | 615.0 | 77.0 | False | None | None | False | None | False | 47355.0 | 0 |
4097706 | 159620 | None | code408 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. | Each | 1962.0 | 1962.0 | 2.0 | False | None | None | False | None | False | 3924.0 | 0 |
4097707 | 159620 | None | code409 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. - Upto 3 HP pumps | Each | 6500.0 | 6500.0 | 1.0 | False | None | None | False | None | False | 6500.0 | 0 |
4097708 | 159620 | None | code410 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. - 3.00 HP/2.2KW - 9 STG | Each | 20113.0 | 20113.0 | 2.0 | False | None | None | False | None | False | 40226.0 | 0 |
4097709 | 159620 | None | code411 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. - 1x3x6 Sqm. | m | 185.0 | 185.0 | 30.0 | False | None | None | False | None | False | 5550.0 | 0 |
4097710 | 159620 | None | code412 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1002.0 | 1002.0 | 12.56 | False | None | None | False | None | False | 12585.12 | 0 |
4097711 | 159620 | None | code413 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineerin- charge. | Cum | 1186.0 | 1186.0 | 12.56 | False | None | None | False | None | False | 14896.16 | 0 |
4097712 | 159620 | None | code414 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1192.0 | 1192.0 | 12.56 | False | None | None | False | None | False | 14971.52 | 0 |
4097713 | 159620 | None | code415 | Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 928.0 | 928.0 | 5.76 | False | None | None | False | None | False | 5345.28 | 0 |
4097714 | 159620 | None | code416 | Design, supplying, erecting testing and commissioning of - Passenger/ Bed - cum - passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V3 phase 50 cycles AC supply, powder coated/ Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED carillumination, emergency light, inter comand fan as desired by the user, central opening/ side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fire mandrive, SS hand rails inside car, full length infra red curtain in car door, automatic rescue device with batteries, voice announcing in regional/ international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS 14665 /2016 (with latest amendments) part/ section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressures witch, manual change over for doors during emergency, ARD of 10 times with sufficient battery backup and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. - D With Out Machine Room-SS Finish - Capacity of 13 Passengers - 5 Stops | Each | 1884540.14 | 1884540.14 | 1.0 | False | None | None | False | None | False | 1884540.14 | 0 |
4097715 | 159620 | None | code417 | Waste water Treatment by Bio Sewage Treatment Plant (Bio STP) onsite construction [25 KLD and 50 KLD ]: Providing, installation and commissioning of anaerobic Bio Sewage Treatment Plant (Bio STP) for black water with all necessary accessories such as pre- filter, pipes for the onsite constructed ABD tank as per the prescribed specification, according to the capacity, with a baffle wall to control the flow of water and to increase the retention time in the RCC ABD Tank. It includes an internal matrix for enhanced growth of bacteria, rising and falling pipes. For grey water, pre - filter, oil skimmer is provided along with an aerator. Post filter such as sand and carbon filter are also included as per the enclosed detailed technical specification attached as Annexure-2, including cost of material, loading and unloading and as directed by the engineer in charge etc., complete, including annual maintenance of the system for 5 years. Note: 1. Above rates mentioned are for the preparation of estimate purpose only. 2. All items are of ISI standards. 3. After commissioning of plant necessary testing to be done for the Satisfaction of the Engineer in charge. 4. Design drawing of the system suitable for erection 50 KLD is given in figure for reference. - 50 KLD | Each | 2545000.0 | 2545000.0 | 1.0 | False | None | None | False | None | False | 2545000.0 | 0 |
4097716 | 159620 | None | code418 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1101.6 | m | 7958.0 | 7958.0 | 5.0 | False | None | None | False | None | False | 39790.0 | 0 |
4097717 | 159620 | None | code419 | Cost of Haulage Excluding Loading and Unloading - Case-1 : Surfaced Road - a Taking output 10 t load and lead 10 km = 100 km | Km | 15.36 | 15.36 | 240.0 | False | None | None | False | None | False | 3686.4 | 0 |
4097718 | 159620 | None | code420 | Supplying and fixing M15 grade precast cement concrete Kerb
stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge.
(The cost of PCC shall be paid extra) - 600 x 300 x 100 mm size | m | 266.0 | 266.0 | 400.0 | False | None | None | False | None | False | 106400.0 | 0 |
4097719 | 159620 | None | code421 | Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. | Each | 61060.0 | 61060.0 | 5.0 | False | None | None | False | None | False | 305300.0 | 0 |