tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1727440601000 | 0 | None | None | Buildings | Construction Of Rooms | 2447422.95 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4096903 | 159594 | None | code01 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 95.0 | 95.0 | 200.0 | False | None | None | False | None | False | 19000.0 | 0 | 4096904 | 159594 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 102.0 | 102.0 | 32.105 | False | None | None | False | None | False | 3274.71 | 0 | 4096905 | 159594 | None | code03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 363.0 | 363.0 | 36.54 | False | None | None | False | None | False | 13264.02 | 0 | 4096906 | 159594 | None | code04 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 5664.0 | 5664.0 | 7.13 | False | None | None | False | None | False | 40384.32 | 0 | 4096907 | 159594 | None | code05 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 5611.0 | 5611.0 | 42.96 | False | None | None | False | None | False | 241048.56 | 0 | 4096908 | 159594 | None | code06 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 6336.0 | 6336.0 | 10.79 | False | None | None | False | None | False | 68365.44 | 0 | 4096909 | 159594 | None | code07 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -do- Additionalities for Formwork, Centring & Scaffolding for Column Footing ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 506.88 | 506.88 | 10.79 | False | None | None | False | None | False | 5469.2352 | 0 | 4096910 | 159594 | None | code08 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 6336.0 | 6336.0 | 0.9 | False | None | None | False | None | False | 5702.4 | 0 | 4096911 | 159594 | None | code09 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -do- Additionalities for Formwork, Centring & Scaffolding for Columns ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 4435.2 | 4435.2 | 0.9 | False | None | None | False | None | False | 3991.68 | 0 | 4096912 | 159594 | None | code10 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 6336.0 | 6336.0 | 5.42 | False | None | None | False | None | False | 34341.12 | 0 | 4096913 | 159594 | None | code11 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -do- Additionalities for Formwork, Centring & Scaffolding for Plinth beam ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 3168.0 | 3168.0 | 5.42 | False | None | None | False | None | False | 17170.56 | 0 | 4096914 | 159594 | None | code12 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 6843.0 | 6843.0 | 4.554 | False | None | None | False | None | False | 31163.022 | 0 | 4096915 | 159594 | None | code13 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -do- Additionalities for Formwork, Centring & Scaffolding for Columns ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 4790.1 | 4790.1 | 4.554 | False | None | None | False | None | False | 21814.1154 | 0 | 4096916 | 159594 | None | code14 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 6843.0 | 6843.0 | 1.81 | False | None | None | False | None | False | 12385.83 | 0 | 4096917 | 159594 | None | code15 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -do- Additionalities for Formwork, Centring & Scaffolding for Lintel ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 4105.8 | 4105.8 | 1.81 | False | None | None | False | None | False | 7431.498 | 0 | 4096918 | 159594 | None | code16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 6843.0 | 6843.0 | 0.38 | False | None | None | False | None | False | 2600.34 | 0 | 4096919 | 159594 | None | code17 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -do- Additionalities for Formwork, Centring & Scaffolding for Chejja ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 3079.35 | 3079.35 | 0.38 | False | None | None | False | None | False | 1170.153 | 0 | 4096920 | 159594 | None | code18 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 6843.0 | 6843.0 | 8.14 | False | None | None | False | None | False | 55702.02 | 0 | 4096921 | 159594 | None | code19 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -do- Additionalities for Formwork, Centring & Scaffolding for Roof Beam ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 4105.8 | 4105.8 | 8.14 | False | None | None | False | None | False | 33421.212 | 0 | 4096922 | 159594 | None | code20 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 6843.0 | 6843.0 | 19.75 | False | None | None | False | None | False | 135149.25 | 0 | 4096923 | 159594 | None | code21 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -do- Additionalities for Formwork, Centring & Scaffolding for Slab ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 3421.5 | 3421.5 | 19.75 | False | None | None | False | None | False | 67574.625 | 0 | 4096924 | 159594 | None | code22 | Polyurethane based Single Component for New Surface : Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 817.0 | 817.0 | 143.64 | False | None | None | False | None | False | 117353.88 | 0 | 4096925 | 159594 | None | code23 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 266.0 | 266.0 | 27.32 | False | None | None | False | None | False | 7267.12 | 0 | 4096926 | 159594 | None | code24 | Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded with desired compaction. (Royalty shall be recovered @ Rs. 60.00/m3 ) ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 119.0 | 119.0 | 139.61 | False | None | None | False | None | False | 16613.59 | 0 | 4096927 | 159594 | None | code25 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 7969.0 | 7969.0 | 35.32 | False | None | None | False | None | False | 281465.08 | 0 | 4096928 | 159594 | None | code26 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Kg | 89.45 | 89.45 | 3716.17 | False | None | None | False | None | False | 332411.4065 | 0 | 4096929 | 159594 | None | code27 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 333.0 | 333.0 | 253.87 | False | None | None | False | None | False | 84538.71 | 0 | 4096930 | 159594 | None | code28 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 241.0 | 241.0 | 185.76 | False | None | None | False | None | False | 44768.16 | 0 | 4096931 | 159594 | None | code29 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 211.0 | 211.0 | 98.4 | False | None | None | False | None | False | 20762.4 | 0 | 4096932 | 159594 | None | code30 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 6551.0 | 6551.0 | 12.96 | False | None | None | False | None | False | 84900.96 | 0 | 4096933 | 159594 | None | code31 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 98815.0 | 98815.0 | 0.135 | False | None | None | False | None | False | 13340.025 | 0 | 4096934 | 159594 | None | code32 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 5742.0 | 5742.0 | 5.76 | False | None | None | False | None | False | 33073.92 | 0 | 4096935 | 159594 | None | code33 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 183.0 | 183.0 | 272.16 | False | None | None | False | None | False | 49805.28 | 0 | 4096936 | 159594 | None | code34 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Cum | 5664.0 | 5664.0 | 13.21 | False | None | None | False | None | False | 74821.44 | 0 | 4096937 | 159594 | None | code35 | Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 1238.0 | 1238.0 | 98.4 | False | None | None | False | None | False | 121819.2 | 0 | 4096938 | 159594 | None | code36 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 1545.0 | 1545.0 | 34.41 | False | None | None | False | None | False | 53163.45 | 0 | 4096939 | 159594 | None | code37 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 1106.0 | 1106.0 | 65.28 | False | None | None | False | None | False | 72199.68 | 0 | 4096940 | 159594 | None | code38 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 89.0 | 89.0 | 247.12 | False | None | None | False | None | False | 21993.68 | 0 | 4096941 | 159594 | None | code39 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 138.0 | 138.0 | 5.76 | False | None | None | False | None | False | 794.88 | 0 | 4096942 | 159594 | None | code40 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Kg | 138.0 | 138.0 | 755.79 | False | None | None | False | None | False | 104299.02 | 0 | 4096943 | 159594 | None | code41 | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete.. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 475.0 | 475.0 | 8.64 | False | None | None | False | None | False | 4104.0 | 0 | 4096944 | 159594 | None | code42 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 100.0 | 100.0 | 120.48 | False | None | None | False | None | False | 12048.0 | 0 | 4096945 | 159594 | None | code43 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 137.0 | 137.0 | 218.88 | False | None | None | False | None | False | 29986.56 | 0 | 4096946 | 159594 | None | code44 | Providing and supplying 18mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. for use in partitions, boxes, side tables, bedside tables, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge . ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 700.0 | 700.0 | 10.8 | False | None | None | False | None | False | 7560.0 | 0 | 4096947 | 159594 | None | code45 | Providing and supplying cupboard shutter with 19mm thick one side Architect recommended decorative laminate (1mm thick) and other side balancing lamination(preferably white) on factory pressed BWP grade marine ply as per IS 710 of approved brand complete as per direction of engineer in-charge. (Payment for providing and fixing auto closing hinges shall be paid separately) ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 2960.0 | 2960.0 | 5.04 | False | None | None | False | None | False | 14918.4 | 0 | 4096948 | 159594 | None | code46 | Labour & installation charges for BWP ply:BWR ply:HDHMR: MDF & Particle board work of any thickness applicable for all types of work ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Sqm | 2000.0 | 2000.0 | 5.04 | False | None | None | False | None | False | 10080.0 | 0 | 4096949 | 159594 | None | code47 | Providing and fixing stainless steel 304 grade fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-incharge. 150 mm length ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | No | 1350.0 | 1350.0 | 4.0 | False | None | None | False | None | False | 5400.0 | 0 | 4096950 | 159594 | None | code48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Mtr | 197.0 | 197.0 | 30.0 | False | None | None | False | None | False | 5910.0 | 0 | 4096951 | 159594 | None | code49 | Providing and fixing Stainless Steel 304 grade soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | No | 400.0 | 400.0 | 4.0 | False | None | None | False | None | False | 1600.0 | 0 |
| 1727440601000 | 0 | None | None | Buildings | Electrical Work | 90763.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4096952 | 159595 | None | code01 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required. 25 mm ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Mtr | 35.0 | 35.0 | 50.0 | False | None | None | False | None | False | 1750.0 | 0 | 4096953 | 159595 | None | code02 | Point wiring using Copper wire with switch.: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Point | 394.0 | 394.0 | 15.0 | False | None | None | False | None | False | 5910.0 | 0 | 4096954 | 159595 | None | code03 | Point wiring using Copper wire with switch.: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Point | 570.0 | 570.0 | 5.0 | False | None | None | False | None | False | 2850.0 | 0 | 4096955 | 159595 | None | code04 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010, 1.5 mm2 ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Mtr | 26.0 | 26.0 | 100.0 | False | None | None | False | None | False | 2600.0 | 0 | 4096956 | 159595 | None | code05 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010, 2.5 mm2 ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Mtr | 42.0 | 42.0 | 75.0 | False | None | None | False | None | False | 3150.0 | 0 | 4096957 | 159595 | None | code06 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010, 4 mm2 ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Mtr | 63.0 | 63.0 | 100.0 | False | None | None | False | None | False | 6300.0 | 0 | 4096958 | 159595 | None | code07 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 1-2 Way ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 138.0 | 138.0 | 5.0 | False | None | None | False | None | False | 690.0 | 0 | 4096959 | 159595 | None | code08 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 8 Way ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 261.0 | 261.0 | 5.0 | False | None | None | False | None | False | 1305.0 | 0 | 4096960 | 159595 | None | code09 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 137.0 | 137.0 | 5.0 | False | None | None | False | None | False | 685.0 | 0 | 4096961 | 159595 | None | code10 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 284.0 | 284.0 | 10.0 | False | None | None | False | None | False | 2840.0 | 0 | 4096962 | 159595 | None | code11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 171.0 | 171.0 | 20.0 | False | None | None | False | None | False | 3420.0 | 0 | 4096963 | 159595 | None | code12 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Stepped Fan Regulator Two Module ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 357.0 | 357.0 | 5.0 | False | None | None | False | None | False | 1785.0 | 0 | 4096964 | 159595 | None | code13 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 690.0 | 690.0 | 8.0 | False | None | None | False | None | False | 5520.0 | 0 | 4096965 | 159595 | None | code14 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 32 A ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 241.0 | 241.0 | 5.0 | False | None | None | False | None | False | 1205.0 | 0 | 4096966 | 159595 | None | code15 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 | 4096967 | 159595 | None | code16 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A DP ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 | 4096968 | 159595 | None | code17 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. III - Double Door 4 Way TP & N ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 4038.0 | 4038.0 | 1.0 | False | None | None | False | None | False | 4038.0 | 0 | 4096969 | 159595 | None | code18 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | No | 743.0 | 743.0 | 1.0 | False | None | None | False | None | False | 743.0 | 0 | 4096970 | 159595 | None | code19 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | No | 676.0 | 676.0 | 2.0 | False | None | None | False | None | False | 1352.0 | 0 | 4096971 | 159595 | None | code20 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Kg | 310.0 | 310.0 | 2.0 | False | None | None | False | None | False | 620.0 | 0 | 4096972 | 159595 | None | code21 | Digging of Pit for providing GI Pipe type Earthing Hard Soil ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Pit | 2990.0 | 2990.0 | 1.0 | False | None | None | False | None | False | 2990.0 | 0 | 4096973 | 159595 | None | code22 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 56" Sweep 5 Star (1400 mm) ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 3754.0 | 3754.0 | 10.0 | False | None | None | False | None | False | 37540.0 | 0 | 4096974 | 159595 | None | code23 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 8" x 6" x 1.5" ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 87.0 | 87.0 | 5.0 | False | None | None | False | None | False | 435.0 | 0 | 4096975 | 159595 | None | code24 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.12" x 12" x 2" ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 181.0 | 181.0 | 5.0 | False | None | None | False | None | False | 905.0 | 0 | 4096976 | 159595 | None | code25 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / Girders ---- Charges with all lead and lift including other incidental charges wherever necessary for successful completion of work and as directed by the Engineer in charge of work. | Each | 122.0 | 122.0 | 8.0 | False | None | None | False | None | False | 976.0 | 0 |
|
|
---|