1727355649000 | 0 | None | None | Buildings | Construction of Government H.P.S school Building at Malagi village of Badami Taluk Bagalkot District | 1170003.47 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4087880 | 159164 | None | AEEBDM001 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels , key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work PWD SR 2023-24 Vol-I , P.No-29 , I.No-1.4 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 242.0 | 242.0 | 47.2 | False | None | None | False | None | False | 11422.4 | 0 | 4087881 | 159164 | None | AEEBDM002 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 Vol-I , P.No-58 , I.No-2.1.2 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 5664.0 | 5664.0 | 5.42 | False | None | None | False | None | False | 30698.88 | 0 | 4087882 | 159164 | None | AEEBDM003 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. PWD SR 2023-24 Vol-I , P.No-7 , I.No-1.9 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 266.0 | 266.0 | 81.32 | False | None | None | False | None | False | 21631.12 | 0 | 4087883 | 159164 | None | AEEBDM004 | Providing and laying in position Cement Concrete for all Foundation works. The granite / trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 Vol-I , P.No-15 , I.No-2.2.1 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 6287.0 | 6287.0 | 8.06 | False | None | None | False | None | False | 50673.22 | 0 | 4087884 | 159164 | None | AEEBDM005 | Centering and shuttering for Foundation upto Plinth according to the Table For Finished rate of Concrete PWD SR 2023-24 Vol-I , P.No-111 , sl.no 1.a with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 502.96 | 502.96 | 8.06 | False | None | None | False | None | False | 4053.8576 | 0 | 4087885 | 159164 | None | AEEBDM006 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m eight. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 Vol-I ,P.No-16 , I.No-2.5.1 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 6630.0 | 6630.0 | 3.46 | False | None | None | False | None | False | 22939.8 | 0 | 4087886 | 159164 | None | AEEBDM007 | Centering and shuttering for RCC Columns / Shaft (Slip Centering) according to the Table For Finished rate of Concrete PWD SR 2023-24 Vol-I , P.No-111 , sl.no 9 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 4641.0 | 4641.0 | 3.46 | False | None | None | False | None | False | 16057.86 | 0 | 4087887 | 159164 | None | AEEBDM008 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m eight. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 Vol-I ,P.No-16 , I.No-2.5.1 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 6630.0 | 6630.0 | 1.9 | False | None | None | False | None | False | 12597.0 | 0 | 4087888 | 159164 | None | AEEBDM009 | Centering and shuttering for Plinth Beams of Buildings according to the Table For Finished rate of Concrete PWD SR 2023-24 Vol-I , P.No-111 , sl.no 2 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 3315.0 | 3315.0 | 1.9 | False | None | None | False | None | False | 6298.5 | 0 | 4087889 | 159164 | None | AEEBDM010 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m eight. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 Vol-I ,P.No-16 , I.No-2.5.1 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 6630.0 | 6630.0 | 5.31 | False | None | None | False | None | False | 35205.3 | 0 | 4087890 | 159164 | None | AEEBDM011 | Centering and shuttering for RCC Beams, Lintels of Buildings according to the Table For Finished rate of Concrete PWD SR 2023-24 Vol-I , P.No-112 , sl.no 14 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 3978.0 | 3978.0 | 5.31 | False | None | None | False | None | False | 21123.18 | 0 | 4087891 | 159164 | None | AEEBDM012 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m eight. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 6630.0 | 6630.0 | 7.75 | False | None | None | False | None | False | 51382.5 | 0 | 4087892 | 159164 | None | AEEBDM013 | Centering and shuttering for RCC Roof Slabs of Buildings according to the Table For Finished rate of Concrete PWD SR 2023-24 Vol-I , P.No-112 , sl.no 15 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 3315.0 | 3315.0 | 7.75 | False | None | None | False | None | False | 25691.25 | 0 | 4087893 | 159164 | None | AEEBDM014 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.buildings PWD SR 2023-24 Vol-I ,P.No-18 , I.No-2.11 a with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Tonne | 89457.0 | 89457.0 | 1.8208 | False | None | None | False | None | False | 162883.3056 | 0 | 4087894 | 159164 | None | AEEBDM015 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) PWD SR 2023-24 Vol-II ,P.No-9 , I.No-5.1.1 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 5611.0 | 5611.0 | 29.08 | False | None | None | False | None | False | 163167.88 | 0 | 4087895 | 159164 | None | AEEBDM016 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. PWD SR 2023-24 Vol-II ,P.No-14 , I.No-6.8 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 7969.0 | 7969.0 | 15.51 | False | None | None | False | None | False | 123599.19 | 0 | 4087896 | 159164 | None | AEEBDM017 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc tions of Engineer-in-charge PWD SR 2023-24 Vol-II ,P.No-41 , I.No-8.3.2 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 333.0 | 333.0 | 216.43 | False | None | None | False | None | False | 72071.19 | 0 | 4087897 | 159164 | None | AEEBDM018 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 Vol-II ,P.No-41 , I.No-8.1.2 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 241.0 | 241.0 | 50.56 | False | None | None | False | None | False | 12184.96 | 0 | 4087898 | 159164 | None | AEEBDM019 | Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge PWD SR 2023-24 Vol-II , P.No-59 , I.No-9.4 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 6666.0 | 6666.0 | 5.17 | False | None | None | False | None | False | 34463.22 | 0 | 4087899 | 159164 | None | AEEBDM020 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.(PWD SR 2021-22 / Volumme II / I.NO-9.34 /P.NO-64) As per SE Issue Rate 07/07/2022 PWD SR 2023-24 Vol-II , P-64 , I-9.34 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 1545.0 | 1545.0 | 53.92 | False | None | None | False | None | False | 83306.4 | 0 | 4087900 | 159164 | None | AEEBDM021 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. PWD SR 2023-24 Vol-II , P.No-99, I.No- 12.12 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 124202.0 | 124202.0 | 0.221 | False | None | None | False | None | False | 27448.642 | 0 | 4087901 | 159164 | None | AEEBDM022 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. PWD SR 2023-24 Vol-II , P.No-104, I.No- 12.51 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Nos | 1016.0 | 1016.0 | 1.0 | False | None | None | False | None | False | 1016.0 | 0 | 4087902 | 159164 | None | AEEBDM023 | Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m.including cost of materials, labour charges, complete as per specifications. with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Nos | 773.0 | 773.0 | 3.0 | False | None | None | False | None | False | 2319.0 | 0 | 4087903 | 159164 | None | AEEBDM024 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding PWD SR 2023-24 Vol-II , P.No-86, I.No- 11.34A with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Kg | 168.0 | 168.0 | 92.72 | False | None | None | False | None | False | 15576.96 | 0 | 4087904 | 159164 | None | AEEBDM025 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures PWD SR 2023-24 Vol-II , P.No-100, I.No- 12.15 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 7444.0 | 7444.0 | 2.52 | False | None | None | False | None | False | 18758.88 | 0 | 4087905 | 159164 | None | AEEBDM026 | Providing and fixing in position Honnewood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures)PWD SR 2023-24 Vol-II , P.No-101, I.No- 12.23 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 7574.0 | 7574.0 | 4.32 | False | None | None | False | None | False | 32719.68 | 0 | 4087906 | 159164 | None | AEEBDM027 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. PWD SR 2023-24 Vol-II , P.No-50, I.No- 8.51 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 100.0 | 100.0 | 125.09 | False | None | None | False | None | False | 12509.0 | 0 | 4087907 | 159164 | None | AEEBDM028 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 Vol-II , P.No-44, I.No- 8.25 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 137.0 | 137.0 | 125.09 | False | None | None | False | None | False | 17137.33 | 0 | 4087908 | 159164 | None | AEEBDM029 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 Vol-II , P.No-46, I.No- 8.30 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 174.0 | 174.0 | 216.43 | False | None | None | False | None | False | 37658.82 | 0 | 4087909 | 159164 | None | AEEBDM030 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 Vol-II , P.No-48, I.No- 8.40 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 115.0 | 115.0 | 13.68 | False | None | None | False | None | False | 1573.2 | 0 | 4087910 | 159164 | None | AEEBDM031 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc 125x65x2.12mm PWD SR 2023-24 Vol-II , P.No-106, I.No- 12.68.1 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Nos | 55.0 | 55.0 | 18.0 | False | None | None | False | None | False | 990.0 | 0 | 4087911 | 159164 | None | AEEBDM032 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick ma sonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm PWD SR 2023-24 Vol-II , P.No-69, I.No- 10.6.3 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Each | 60.0 | 60.0 | 18.0 | False | None | None | False | None | False | 1080.0 | 0 | 4087912 | 159164 | None | AEEBDM033 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete PWD SR 2023-24 Vol-II , P.No-106, I.No- 12.62 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Nos | 237.0 | 237.0 | 2.0 | False | None | None | False | None | False | 474.0 | 0 | 4087913 | 159164 | None | AEEBDM034 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete PWD SR 2023-24 Vol-II , P.No-105, I.No- 12.63 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Nos | 130.0 | 130.0 | 16.0 | False | None | None | False | None | False | 2080.0 | 0 | 4087914 | 159164 | None | AEEBDM035 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm
with suitable washers weighing not less than 33 gms PWD SR 2023-24 Vol-II , P.No-105, I.No- 12.64 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Nos | 55.0 | 55.0 | 2.0 | False | None | None | False | None | False | 110.0 | 0 | 4087915 | 159164 | None | AEEBDM036 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter PWD SR 2023-24 Vol-II , P.No-125, I.No- 13.47 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Mtr | 197.0 | 197.0 | 2.0 | False | None | None | False | None | False | 394.0 | 0 | 4087916 | 159164 | None | AEEBDM037 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge PWD SR 2023-24 Vol-II , P.No-84, I.No- 11.26.1 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Kg | 138.0 | 138.0 | 64.63 | False | None | None | False | None | False | 8918.94 | 0 | 4087917 | 159164 | None | AEEBDM038 | ELECTRIFICATION Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-2, I.No- 1.2.1 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Mtr | 66.0 | 66.0 | 25.0 | False | None | None | False | None | False | 1650.0 | 0 | 4087918 | 159164 | None | AEEBDM039 | Supplying heavy gauge PVC Conduit Pipe ….dia .....mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20mm dia 2mm thick PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-2, I.No- 1.3.1 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Mtr | 68.0 | 68.0 | 15.0 | False | None | None | False | None | False | 1020.0 | 0 | 4087919 | 159164 | None | AEEBDM040 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood. After due groove cutting, necessary masonary patch work complete.10''x7''x3 254x178x76mm with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Each | 112.0 | 112.0 | 2.0 | False | None | None | False | None | False | 224.0 | 0 | 4087920 | 159164 | None | AEEBDM041 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A.Short point upto 3Mtr from tapping point to out let via switch PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-5, I.No- 2.1.1 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Point | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 | 4087921 | 159164 | None | AEEBDM042 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A.Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-5, I.No- 2.1.2 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Point | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 | 4087922 | 159164 | None | AEEBDM043 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A.lpng point above 6Mtr upto 10Mtr from tapping point to outlet via switch PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-5, I.No- 2.1.3 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Point | 570.0 | 570.0 | 4.0 | False | None | None | False | None | False | 2280.0 | 0 | 4087923 | 159164 | None | AEEBDM044 | Wiring for lighting/power circuit using one of PVC insulated 1100V grade, multis and Copper conductor single core cable in open or consealed system of wiring. Using Class 'A' approved materials. PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-5, I.No- 2.3.1 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Mtr | 19.0 | 19.0 | 50.0 | False | None | None | False | None | False | 950.0 | 0 | 4087924 | 159164 | None | AEEBDM045 | Wiring for lighting/power circuit using one of PVC insulated 1100V grade, multis and Copper conductor single core cable in open or consealed system of wiring. Using Class 'A' approved materials. PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-5, I.No- 2.3.3 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Mtr | 42.0 | 42.0 | 50.0 | False | None | None | False | None | False | 2100.0 | 0 | 4087925 | 159164 | None | AEEBDM046 | Wiring for lighting/power circuit using one of PVC insulated 1100V grade, multis and Copper conductor single core cable in open or consealed system of wiring. Using Class 'A' approved materials. PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-5, I.No- 2.3.4 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Mtr | 63.0 | 63.0 | 50.0 | False | None | None | False | None | False | 3150.0 | 0 | 4087926 | 159164 | None | AEEBDM047 | Supply 6A flush/projected type socket and a 6 amps flush/ projected type SP switch either surface/flush mounting in a existing gang box or in a 4mm thick plastic sheet and fixing over a flush monted wooden box and wiring using necessary capacity wires as required.6 Amps 3/5 Way PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-8, I.No- 3.1.2 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Each | 147.0 | 147.0 | 8.0 | False | None | None | False | None | False | 1176.0 | 0 | 4087927 | 159164 | None | AEEBDM048 | Supplying and fixing of modular switch & connected
accessories on existing modular switch plate as per IS 3854 and IS 1293.32 Amps DP switch PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-9, I.No- 3.6.9 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Each | 326.0 | 326.0 | 2.0 | False | None | None | False | None | False | 652.0 | 0 | 4087928 | 159164 | None | AEEBDM049 | Supplying and fixing of modular switch & connected
accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16A Universal Socket PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-9, I.No- 3.6.10 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Each | 236.0 | 236.0 | 2.0 | False | None | None | False | None | False | 472.0 | 0 | 4087929 | 159164 | None | AEEBDM050 | Supplying and fixing of modular switch & connected
accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator Two Module PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-9, I.No- 3.6.4 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Each | 357.0 | 357.0 | 2.0 | False | None | None | False | None | False | 714.0 | 0 | 4087930 | 159164 | None | AEEBDM051 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition 10-12W PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-44, I.No- 11.4.2PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-44, I.No- 11.4.2 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Each | 1269.0 | 1269.0 | 1.0 | False | None | None | False | None | False | 1269.0 | 0 | 4087931 | 159164 | None | AEEBDM052 | Supplying and fixing polished wood board made of not lees then 15mm thick plank on both side with planks made out of more then 2 pieces and fixing the same to the wall using taperd inverted wooden flugs screws etc.8" x 6" x 1.5" PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-14, I.No- 5.6.1 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Each | 87.0 | 87.0 | 1.0 | False | None | None | False | None | False | 87.0 | 0 | 4087932 | 159164 | None | AEEBDM053 | Supplying & fixing of porcelain fuse channel with cut on existing wooden /panel using necessary nuts, bolts and washers etc, complete.32 A PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-14, I.No- 5.7.2 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Each | 241.0 | 241.0 | 1.0 | False | None | None | False | None | False | 241.0 | 0 | 4087933 | 159164 | None | AEEBDM054 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-17, I.No- 5.18.4 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 | 4087934 | 159164 | None | AEEBDM055 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.( II Double Door ).II - Double Door 8 Way SP & N PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-18, I.No- 5.19.8 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Each | 1854.0 | 1854.0 | 1.0 | False | None | None | False | None | False | 1854.0 | 0 | 4087935 | 159164 | None | AEEBDM056 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-30, I.No- 6.3.1 | Each | 2984.0 | 2984.0 | 1.0 | False | None | None | False | None | False | 2984.0 | 0 | 4087936 | 159164 | None | AEEBDM057 | Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the meter board using40mmdia 2.90mmthick GIpipe2.5m long buried in a pit. The pit shouldbe filled with equal proportion of salt and charcoal 150mm allund the pipe to complete depth. The connection from the pipe to the conduit etc.,is to be established through GIwire of size as per lSI specification 7.3.3.ofIS732 using 12mm dia bolts,nuts,washer sand check nuts etc., the pipe shall have 16 through holes of 12 mm dia PWD ELECTRICAL SR 2023-24 Vol-6 , P.No-54, I.No- 12.56 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Each | 3510.0 | 3510.0 | 1.0 | False | None | None | False | None | False | 3510.0 | 0 |
|