createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1727336303788
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd345000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose28-10-2024 16:00:00
tenderQueryClose07-10-2024 16:00:00
technicalBidOpen30-10-2024 16:00:00
publishedDate27-09-2024 16:50:00
publishedByPostKHB_EE2_CO_BNG
publishedByUserKPE11678 - LOKESHBABU C G
bidValidityPeriod180
noOfCalls1
preBidMeetingDate08-10-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonLokesh Babu C G
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022273511
mobileNumber8022273511
tenderSupplierListNone
tenderSchedule
createdTs1727336303806
version4
createdDateNone
modifiedDateNone
tenderNumberKHB/2024-25/BD/WORK_INDENT299
titleConstruction of class rooms, library, laboratory, toilet and other allied works for Government First Grade College at Shidlaghatta in Chikkaballapura District under SCP/TSP 2023-24 scheme
descriptionConstruction of class rooms, library, laboratory, toilet and other allied works for Government First Grade College at Shidlaghatta in Chikkaballapura District under SCP/TSP 2023-24 scheme
categoryWORKS
categoryTextWorks
ecv22759200.00
deptNameKarnataka Housing Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5488
locationNameKHB Central Office Bengaluru
provisionalAmount22759200.0
groupOverheadTotalNone
fileNumber197/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17273363040000NoneNoneBuildingsConstruction of class rooms, library, laboratory, toilet and other allied works for Government First Grade College at Shidlaghatta in Chikkaballapura District under SCP/TSP 2023-24 scheme22759200.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4080896158835Nonecode01Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking to the appropriate disposal area as per direction of Engineer-in-charge Thickness above 40 mm up to 75 mmha300.76300.76222.0FalseNoneNoneFalseNoneFalse66768.720
4080897158835Nonecode02Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungleha404.79404.791.11FalseNoneNoneFalseNoneFalse449.31690
4080898158835Nonecode03Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum97.8597.8533.3FalseNoneNoneFalseNoneFalse3258.4050
4080899158835Nonecode04Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum105.06105.0698.76FalseNoneNoneFalseNoneFalse10375.72560
4080900158835Nonecode05Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depthCum373.89373.8925.6206FalseNoneNoneFalseNoneFalse9579.2861340
4080901158835Nonecode06Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/ Moorum. (Disposal of 10Km)Cum122.57122.5724.69FalseNoneNoneFalseNoneFalse3026.25330
4080902158835Nonecode07Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum273.98273.9898.76FalseNoneNoneFalseNoneFalse27058.26480
4080903158835Nonecode08Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, formwork , cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6168.676168.6723.07FalseNoneNoneFalseNoneFalse142311.21690
4080904158835Nonecode09Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6580.676580.6734.58FalseNoneNoneFalseNoneFalse227559.56860
4080905158835Nonecode10Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, traightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Tonne81381.3381381.333.17FalseNoneNoneFalseNoneFalse257978.81610
4080906158835Nonecode11Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6403.516403.512.1FalseNoneNoneFalseNoneFalse13447.3710
4080907158835Nonecode12Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately) Column C1Cum11094.3411094.347.18FalseNoneNoneFalseNoneFalse79657.36120
4080908158835Nonecode13Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately) FootingCum7048.177048.1721.89FalseNoneNoneFalseNoneFalse154284.44130
4080909158835Nonecode14Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately) Plinth BeamCum9789.129789.1213.32FalseNoneNoneFalseNoneFalse130391.07840
4080910158835Nonecode15Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1349.31349.3237.8FalseNoneNoneFalseNoneFalse320863.540
4080911158835Nonecode16Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm382.13382.13399.0FalseNoneNoneFalseNoneFalse152469.870
4080912158835Nonecode17Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg140.08140.08686.4FalseNoneNoneFalseNoneFalse96150.9120
4080913158835Nonecode18Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever requiredKg585.04585.04224.0FalseNoneNoneFalseNoneFalse131048.960
4080914158835Nonecode19Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 Sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 Sqm to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar dropsSqm291.49291.49399.0FalseNoneNoneFalseNoneFalse116304.510
4080915158835Nonecode20Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer-in-charge Of area 3 Sqm and below GFSqm247.2247.2193.92FalseNoneNoneFalseNoneFalse47937.0240
4080916158835Nonecode21Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer-in-charge Of area 3 Sqm and below First floor WindowsSqm249.67249.67178.56FalseNoneNoneFalseNoneFalse44581.07520
4080917158835Nonecode22Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GFSqm1046.481046.48186.24FalseNoneNoneFalseNoneFalse194896.43520
4080918158835Nonecode23Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. FFSqm1056.941056.94178.56FalseNoneNoneFalseNoneFalse188727.20640
4080919158835Nonecode24Providing and fixing Rabbit wire meshSqm43.2643.26186.24FalseNoneNoneFalseNoneFalse8056.74240
4080920158835Nonecode25Providing and fixing Rabbit wire mesh First floor WindowsSqm43.6943.69178.56FalseNoneNoneFalseNoneFalse7801.28640
4080921158835Nonecode26Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm6747.536747.53186.24FalseNoneNoneFalseNoneFalse1256659.98720
4080922158835Nonecode27Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) First floor WindowsSqm7005.387005.38178.56FalseNoneNoneFalseNoneFalse1250880.65280
4080923158835Nonecode28Providing & fixing Vertical Blinds of reputed make of shape 100mm regular fabric with powder coated aluminium channel, telting with PVC Chain system with all necessary fittings and fixtures as per direction of Engineer in charge GFSqm875.5875.5174.72FalseNoneNoneFalseNoneFalse152967.360
4080924158835Nonecode29Providing & fixing Vertical Blinds of reputed make of shape 100mm regular fabric with powder coated aluminium channel, telting with PVC Chain system with all necessary fittings and fixtures as per direction of Engineer in charge GF First floor WindowsSqm884.26884.26178.56FalseNoneNoneFalseNoneFalse157893.46560
4080925158835Nonecode30Providing & fixing Roller Blinds of reputed make 38mm round Aluminium channel with blackout fabric, telting with chain (Ball) system with all necessary fittings and fixtures as per direction of Engineer in chargeSqm1854.01854.011.52FalseNoneNoneFalseNoneFalse21358.080
4080926158835Nonecode31Providing & Fixing in position Acoustical wall panelling with Integral Densified Square/Butt edged Fully Perforated Eco Friendly Lightweight Calcium Silicate panels/tiles with fabricated galvanised mild steel frame work for Auditoriums, Community halls, Offices, Institutions, Airports, Meeting halls, Indoor Stadiums and Studios. The Eco Friendly Lightweight Calcium Silicate wall panels/tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials.Sqm3012.753012.7589.82FalseNoneNoneFalseNoneFalse270605.2050
4080927158835Nonecode32Providing and laying 100mm thick factory made precast M -40 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions more than 20MSA upto 50MSA & for Arterial streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.(WMM/WBM Base , DLC to be paid separately as per relevant technical specificationCum1527.491527.49406.1FalseNoneNoneFalseNoneFalse620313.6890
4080928158835Nonecode33Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including ub bing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm2539.982539.98386.1FalseNoneNoneFalseNoneFalse980686.2780
4080929158835Nonecode34Providing waterproof treatment to Raft Slab using 2 coats of acrylic co polymer elastomeric Acrylic co-polymer elastomeric sealer & protector. The surface shall be prepared free of tar, dust, fungus, loose particles etc., The surface shall be applied with basecoat of healer sealer crystallization liquid and then Acrylic co-polymer elastomeric sealer & protector, wetting agent and liquid (1:1:6) over the prepared surface. In addition, making haunch at junction of Wall and Slab visible cracks are opened and sealed with flexicrack paste. Over this one coat of flexible cementations membrane (FCM), Spreading one layer of HDPE membrane as reinforcing material (over FCM) with one primer coat of Acrylic co-polymer elastomeric sealer & protector & applying second coat of Acrylic co-polymer elastomeric sealer & protector liquid over the primer coat - conforming to ASTM C 1202, DIN 1048 part 5, The work shall be carried out as per the directions of the Engineer in charge. Note : The Water Proofing System rates are inclusive of surface prepation and cleaning.Sqm1081.51081.52256.12FalseNoneNoneFalseNoneFalse2439993.780
4080930158835Nonecode35Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.Kg588.13588.13270.44FalseNoneNoneFalseNoneFalse159053.87720
4080931158835Nonecode36Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- in-charge: Pre-laminated particle board with decorative lamination on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm1012.491012.49310.08FalseNoneNoneFalseNoneFalse313952.89920
4080932158835Nonecode37Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ Sqm) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm1017.641017.6410.5FalseNoneNoneFalseNoneFalse10685.220
4080933158835Nonecode38Toughened glass 12 mm thickness with holeSqm2163.02163.020.0FalseNoneNoneFalseNoneFalse43260.00
4080934158835Nonecode39Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge.Cum1712.891712.8912.15FalseNoneNoneFalseNoneFalse20811.61350
4080935158835Nonecode40Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km)Cum122.57122.5712.15FalseNoneNoneFalseNoneFalse1489.22550
4080936158835Nonecode41Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, formwork , cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6168.676168.673.04FalseNoneNoneFalseNoneFalse18752.75680
4080937158835Nonecode42Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately)Cum11094.3411094.349.11FalseNoneNoneFalseNoneFalse101069.43740
4080938158835Nonecode43Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg151.41151.416028.0FalseNoneNoneFalseNoneFalse912699.480
4080939158835Nonecode44Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.Sqm919.79919.79240.0FalseNoneNoneFalseNoneFalse220749.60
4080940158835Nonecode45Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches including cost of labour, material complete as per specifications. Ground floor WindowsSqm13.3913.393736.72FalseNoneNoneFalseNoneFalse50034.68080
4080941158835Nonecode46Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches including cost of labour, material complete as per specifications. First floor WindowsSqm13.5213.522432.96FalseNoneNoneFalseNoneFalse32893.61920
4080942158835Nonecode47Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge GROUND FLOORSqm321.36321.36373.67FalseNoneNoneFalseNoneFalse120082.59120
4080943158835Nonecode48Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge FIRST FLOORSqm324.57324.57243.3FalseNoneNoneFalseNoneFalse78967.8810
4080944158835Nonecode49Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside)Sqm359.47359.47373.67FalseNoneNoneFalseNoneFalse134323.15490
4080945158835Nonecode50Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside)Sqm363.06363.06243.3FalseNoneNoneFalseNoneFalse88332.4980
4080946158835Nonecode51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm103.0103.0747.34FalseNoneNoneFalseNoneFalse76976.020
4080947158835Nonecode52Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FIRST FLOORSqm104.03104.03486.59FalseNoneNoneFalseNoneFalse50619.95770
4080948158835Nonecode53Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 Sqm over and including one coat of Special primer applied @ 0.75 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)Sqm162.74162.743736.72FalseNoneNoneFalseNoneFalse608113.81280
4080949158835Nonecode54Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 Sqm over and including one coat of Special primer applied @ 0.75 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) First Floor Inside wallsSqm164.37164.372432.96FalseNoneNoneFalseNoneFalse399905.63520
4080950158835Nonecode55Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 Sqm over and including one coat of Special primer applied @ 0.75 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) Ground Floor external wallsSqm162.74162.741140.0FalseNoneNoneFalseNoneFalse185523.60
4080951158835Nonecode56Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 Sqm over and including one coat of Special primer applied @ 0.75 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) first Floor external wallsSqm164.37164.371197.0FalseNoneNoneFalseNoneFalse196750.890
4080952158835Nonecode57Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1349.31349.345.0FalseNoneNoneFalseNoneFalse60718.50
4080953158835Nonecode58Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg151.41151.41155.0FalseNoneNoneFalseNoneFalse23468.550
4080954158835Nonecode59Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.Sqm919.79919.7946.5FalseNoneNoneFalseNoneFalse42770.2350
4080955158835Nonecode60Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum97.8597.8599.0FalseNoneNoneFalseNoneFalse9687.150
4080956158835Nonecode61Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum105.06105.0646.85FalseNoneNoneFalseNoneFalse4922.0610
4080957158835Nonecode62Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km)Cum122.57122.5746.85FalseNoneNoneFalseNoneFalse5742.40450
4080958158835Nonecode63Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum273.98273.9846.85FalseNoneNoneFalseNoneFalse12835.9630
4080959158835Nonecode64Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, formwork , cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6168.676168.6767.42FalseNoneNoneFalseNoneFalse415891.73140
4080960158835Nonecode65Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, traightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Tonne81381.3381381.330.51FalseNoneNoneFalseNoneFalse41504.47830
4080961158835Nonecode66Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6403.516403.5133.5FalseNoneNoneFalseNoneFalse214517.5850
4080962158835Nonecode67Providing and laying 100mm thick factory made precast M -40 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions more than 20MSA upto 50MSA & for Arterial streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.(WMM/WBM Base , DLC to be paid separately as per relevant technical specificationCum1527.491527.49335.0FalseNoneNoneFalseNoneFalse511709.150
4080963158835Nonecode68Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately) Column C1Cum11094.3411094.340.76FalseNoneNoneFalseNoneFalse8431.69840
4080964158835Nonecode69Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately) FootingCum7048.177048.178.06FalseNoneNoneFalseNoneFalse56808.25020
4080965158835Nonecode70Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately) Plinth BeamCum9789.129789.122.16FalseNoneNoneFalseNoneFalse21144.49920
4080966158835Nonecode71Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately) Plinth BeamCum9789.129789.120.72FalseNoneNoneFalseNoneFalse7048.16640
4080967158835Nonecode72Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately) Column C1Cum11094.3411094.340.05FalseNoneNoneFalseNoneFalse554.7170
4080968158835Nonecode73Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately) FootingCum7048.177048.170.58FalseNoneNoneFalseNoneFalse4087.93860
4080969158835Nonecode74Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately) Plinth BeamCum9789.129789.120.72FalseNoneNoneFalseNoneFalse7048.16640
4080970158835Nonecode75Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately) Plinth BeamCum9789.129789.120.36FalseNoneNoneFalseNoneFalse3524.08320
4080971158835Nonecode76Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg140.08140.0812600.0FalseNoneNoneFalseNoneFalse1765008.00
4080972158835Nonecode77Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever requiredKg585.04585.04345.0FalseNoneNoneFalseNoneFalse201838.80
4080973158835Nonecode78Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste linesm95.7195.7150.0FalseNoneNoneFalseNoneFalse4785.50
4080974158835Nonecode79Providing and fixing noMal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipesm144.6144.640.0FalseNoneNoneFalseNoneFalse5784.00
4080975158835Nonecode80Providing and fixing noMal gauge PVC pipe - OD 75mm and 6 Kg/sqcm, waste linesm127.96127.9680.0FalseNoneNoneFalseNoneFalse10236.80
4080976158835Nonecode81Providing and fixing noMal gauge PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary linesm265.28265.2870.0FalseNoneNoneFalseNoneFalse18569.60
4080977158835Nonecode82Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameterm204.94204.94100.0FalseNoneNoneFalseNoneFalse20494.00
4080978158835Nonecode83Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Each1269.171269.178.0FalseNoneNoneFalseNoneFalse10153.360
4080979158835Nonecode84C.P. Brass angle valve 15 mmEach455.65455.6520.0FalseNoneNoneFalseNoneFalse9113.00
4080980158835Nonecode85Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lidEach6217.876217.8712.0FalseNoneNoneFalseNoneFalse74614.440
4080981158835Nonecode86Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cisternNo10819.1210819.129.0FalseNoneNoneFalseNoneFalse97372.080
4080982158835Nonecode87Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mmNo5286.85286.89.0FalseNoneNoneFalseNoneFalse47581.20
4080983158835Nonecode88C.P. Brass stop cock (concealed) 15 mmNo546.16546.1620.0FalseNoneNoneFalseNoneFalse10923.20
4080984158835Nonecode89Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar tapsNo3206.23206.24.0FalseNoneNoneFalseNoneFalse12824.80
4080985158835Nonecode90Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall FIRST FLOOR 15 mm nominal dia Pipesm189.33189.3380.0FalseNoneNoneFalseNoneFalse15146.40
4080986158835Nonecode91Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall FIRST FLOOR 20 mm nominal dia Pipesm251.75251.75150.0FalseNoneNoneFalseNoneFalse37762.50
4080987158835Nonecode92Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall FIRST FLOOR 25 mm nominal dia Pipesm330.82330.82130.0FalseNoneNoneFalseNoneFalse43006.60
4080988158835Nonecode93Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall FIRST FLOOR 32 mm nominal dia Pipesm416.12416.12100.0FalseNoneNoneFalseNoneFalse41612.00
4080989158835Nonecode94Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall FIRST FLOOR 40 mm nominal dia Pipesm557.6557.680.0FalseNoneNoneFalseNoneFalse44608.00
4080990158835Nonecode95Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall FIRST FLOOR 50 mm nominal dia Pipesm812.47812.4750.0FalseNoneNoneFalseNoneFalse40623.50
4080991158835Nonecode96Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20 mm nominal dia Pipesm225.75225.75100.0FalseNoneNoneFalseNoneFalse22575.00
4080992158835Nonecode97Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25 mm nominal dia Pipesm307.93307.93110.0FalseNoneNoneFalseNoneFalse33872.30
4080993158835Nonecode98Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 32 mm nominal dia Pipesm386.99386.99100.0FalseNoneNoneFalseNoneFalse38699.00
4080994158835Nonecode99Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40 mm nominal dia Pipesm496.22496.2280.0FalseNoneNoneFalseNoneFalse39697.60
4080995158835Nonecode100Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50 mm nominal dia Pipesm750.06750.0660.0FalseNoneNoneFalseNoneFalse45003.60
4080996158835Nonecode101Providing and fixing brass bib cock of approved quality :15 mm nominal boreEach297.53297.5320.0FalseNoneNoneFalseNoneFalse5950.60
4080997158835Nonecode102Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.l9.369.364000.0FalseNoneNoneFalseNoneFalse37440.00
4080998158835Nonecode103Providing and fixing expandable fasteners of specified size with neces sary plastic sleeves and galvanised M.S. screws including drilling holes in masonry work / CC/ R.C.C. and making good etc. complete. 25 mm longNo26.026.030.0FalseNoneNoneFalseNoneFalse780.00
4080999158835Nonecode104Providing and fixing expandable fasteners of specified size with neces sary plastic sleeves and galvanised M.S. screws including drilling holes in masonry work / CC/ R.C.C. and making good etc. complete. 32 mm longNo28.028.030.0FalseNoneNoneFalseNoneFalse840.00
4081000158835Nonecode105Providing and fixing expandable fasteners of specified size with neces sary plastic sleeves and galvanised M.S. screws including drilling holes in masonry work / CC/ R.C.C. and making good etc. complete. 40 mm longNo30.030.030.0FalseNoneNoneFalseNoneFalse900.00
4081001158835Nonecode106Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tapsNo3206.23206.26.0FalseNoneNoneFalseNoneFalse19237.20
4081002158835Nonecode107Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories completeNo253.83253.8328.0FalseNoneNoneFalseNoneFalse7107.240
4081003158835Nonecode108Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesNo300.65300.6530.0FalseNoneNoneFalseNoneFalse9019.50
4081004158835Nonecode109Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesNo296.49296.4930.0FalseNoneNoneFalseNoneFalse8894.70
4081005158835Nonecode110Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150mm nominal dia pipesNo798.95798.9530.0FalseNoneNoneFalseNoneFalse23968.50
4081006158835Nonecode111Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. Item No 2.1 2.1.1)Short point upto 3Mtr from tapping point to out let via switch boxNo303.85303.8550.0FalseNoneNoneFalseNoneFalse15192.50
4081007158835Nonecode112Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. Item No 2.1 2.1.2)Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo424.36424.3660.0FalseNoneNoneFalseNoneFalse25461.60
4081008158835Nonecode113Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. Item No 2.1 2.1.3)Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo623.15623.15150.0FalseNoneNoneFalseNoneFalse93472.50
4081009158835Nonecode114Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. Item No 2.1 2.1.4)Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switchesNo793.1793.1100.0FalseNoneNoneFalseNoneFalse79310.00
4081010158835Nonecode115Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. Item No 2.1 2.1.5)Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches boxNo1158.751158.7550.0FalseNoneNoneFalseNoneFalse57937.50
4081011158835Nonecode116Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Item No 3.4 3.4.1) 1-3WayEach134.93134.9370.0FalseNoneNoneFalseNoneFalse9445.10
4081012158835Nonecode117Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Item No 3.4 3.4.2)4-5WayEach151.41151.4120.0FalseNoneNoneFalseNoneFalse3028.20
4081013158835Nonecode118Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Item No 3.4 3.4.3)6 WayEach232.78232.7870.0FalseNoneNoneFalseNoneFalse16294.60
4081014158835Nonecode119Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Item No 3.4 3.4.4)8WayEach273.98273.982.0FalseNoneNoneFalseNoneFalse547.960
4081015158835Nonecode120Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Item No 3.4 3.4.5) 10-12WayEach357.41357.411.0FalseNoneNoneFalseNoneFalse357.410
4081016158835Nonecode121Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Item No 3.4 3.4.6)16-18 WayEach389.34389.3450.0FalseNoneNoneFalseNoneFalse19467.00
4081017158835Nonecode122Suppling and fixing PVC/metal conduit deep junction boxes. Item No 1.5 1.5.1)19/20mm deep junction boxEach53.5653.5621.0FalseNoneNoneFalseNoneFalse1124.760
4081018158835Nonecode123Suppling and fixing PVC/metal conduit deep junction boxes. Item No 1.5 1.5.2) 25mm deep junction boxEach56.6556.65300.0FalseNoneNoneFalseNoneFalse16995.00
4081019158835Nonecode124Suppling and fixing PVC/metal conduit deep junction boxes. Item No 1.5 1.5.3) 32mm deep junction boxEach75.1975.1910.0FalseNoneNoneFalseNoneFalse751.90
4081020158835Nonecode125Suppling and fixing PVC/metal conduit deep junction boxes. Item No 1.5 1.12)Supply and fixing Metal Fan Box with Round HookEach179.22179.22100.0FalseNoneNoneFalseNoneFalse17922.00
4081021158835Nonecode126Supplying and mounting 2 nos of 2 way 6amps flush type switches either surface /flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as required . Item No 3.2Each178.19178.193.0FalseNoneNoneFalseNoneFalse534.570
4081022158835Nonecode127Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Item No 3.5 3.5.1)1 to 3 ModuleEach166.86166.8650.0FalseNoneNoneFalseNoneFalse8343.00
4081023158835Nonecode128Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Item No 3.5 3.5.2) 4 ModuleEach191.58191.5820.0FalseNoneNoneFalseNoneFalse3831.60
4081024158835Nonecode129Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Item No 3.5 3.5.3) 6 ModuleEach267.8267.850.0FalseNoneNoneFalseNoneFalse13390.00
4081025158835Nonecode130Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Item No 3.5 3.5.4)8 ModuleEach331.66331.662.0FalseNoneNoneFalseNoneFalse663.320
4081026158835Nonecode131Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Item No 3.5 3.5.5)10-12 ModuleEach398.61398.611.0FalseNoneNoneFalseNoneFalse398.610
4081027158835Nonecode132Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Item No 3.5 3.5.6)16-18 ModuleEach442.9442.967.0FalseNoneNoneFalseNoneFalse29674.30
4081028158835Nonecode133Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.. Item No 3.6 3.6.1) 6 Amps one wayEach96.8296.82114.0FalseNoneNoneFalseNoneFalse11037.480
4081029158835Nonecode134Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.. Item No 3.6 3.6.2) 6 Amps Two wayEach166.86166.8610.0FalseNoneNoneFalseNoneFalse1668.60
4081030158835Nonecode135Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.. Item No 3.6 3.6.3) 6 Amps 3way socket.Each178.19178.19150.0FalseNoneNoneFalseNoneFalse26728.50
4081031158835Nonecode136Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.. Item No 3.6 3.6.4) Stepped Fan Regulator Two ModuleEach344.02344.02100.0FalseNoneNoneFalseNoneFalse34402.00
4081032158835Nonecode137Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.. Item No 3.6 3.6.8) 16A mps one wayEach273.98273.98100.0FalseNoneNoneFalseNoneFalse27398.00
4081033158835Nonecode138Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.. Item No 3.6 3.6.11) 6/16A aps universal socket.Each273.98273.98100.0FalseNoneNoneFalseNoneFalse27398.00
4081034158835Nonecode139Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.. Item No 3.6 3.6.12) tv/telephone socketEach161.71161.7123.0FalseNoneNoneFalseNoneFalse3719.330
4081035158835Nonecode140Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.. Item No 3.6 3.6.13) rj45/i.o outlet cat 6Each231.75231.7539.0FalseNoneNoneFalseNoneFalse9038.250
4081036158835Nonecode141Supplying and fixing of metal clad industrial plugs and sockets. 2pole+earth 250V PLUG 20AEach242.05242.0522.0FalseNoneNoneFalseNoneFalse5325.10
4081037158835Nonecode142Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. Item No 1.2 1.2.1) 19/20mm dia 2mm thickm66.9566.955000.0FalseNoneNoneFalseNoneFalse334750.00
4081038158835Nonecode143Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. Item No 1.2 1.2.2) 25mm dia 2mm thickm77.2577.252500.0FalseNoneNoneFalseNoneFalse193125.00
4081039158835Nonecode144Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. Item No 1.2 1.2.3) 32mm dia 2.5mm thickm101.97101.97150.0FalseNoneNoneFalseNoneFalse15295.50
4081040158835Nonecode145Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. Item No 1.3 1.3.1) 19/20mm dia 2mm thickm82.482.4800.0FalseNoneNoneFalseNoneFalse65920.00
4081041158835Nonecode146Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. Item No 1.3 1.3.2) 25mm dia 2mm thickm87.5587.55800.0FalseNoneNoneFalseNoneFalse70040.00
4081042158835Nonecode147Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. Item No 1.3 1.3.3) 32mm dia 2.5mm thickm115.36115.3615.0FalseNoneNoneFalseNoneFalse1730.40
4081043158835Nonecode148Wiring for lighting /power circuit using one of PVC insulated 1100v grade,multis and Copper conductor single core cable in open or concealed system of wiring. Item No 2.3 2.3.2) 1.5 sqmmm27.8127.813000.0FalseNoneNoneFalseNoneFalse83430.00
4081044158835Nonecode149Wiring for lighting /power circuit using one of PVC insulated 1100v grade,multis and Copper conductor single core cable in open or concealed system of wiring. Item No 2.3 2.3.3) 2.5 sqmmm43.2643.262000.0FalseNoneNoneFalseNoneFalse86520.00
4081045158835Nonecode150Wiring for lighting /power circuit using one of PVC insulated 1100v grade,multis and Copper conductor single core cable in open or concealed system of wiring. Item No 2.3 2.3.4) 4 sqmmm64.8964.891100.0FalseNoneNoneFalseNoneFalse71379.00
4081046158835Nonecode151Wiring for lighting /power circuit using one of PVC insulated 1100v grade,multis and Copper conductor single core cable in open or concealed system of wiring. Item No 2.3 2.3.3) 6 sqmmm95.7995.79300.0FalseNoneNoneFalseNoneFalse28737.00
4081047158835Nonecode152Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694:2010.e. Item No 2.6 2.6.2)3C x 2.5 mm2m124.63124.6330.0FalseNoneNoneFalseNoneFalse3738.90
4081048158835Nonecode153Supplying and fixing regular MCB distribution boards on wall/ wood board /flush mounting required clamps,bolts,nuts etc.. with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting etc., complete. Item No 5.18 II. Double Door 12 Way TP & NEach6319.056319.054.0FalseNoneNoneFalseNoneFalse25276.20
4081049158835Nonecode154Supplying and fixing regular MCB distribution boards on wall/ wood board /flush mounting required clamps,bolts,nuts etc.. with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting etc., complete. Item No 5.18 II. Double Door 8 Way TP & NEach4550.544550.546.0FalseNoneNoneFalseNoneFalse27303.240
4081050158835Nonecode155Supplying and fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up 300mA sensitivity on existing wood/panel board. Item No 5.20 5.20.2)32-40 Amps 2 PoleEach2916.962916.9630.0FalseNoneNoneFalseNoneFalse87508.80
4081051158835Nonecode156Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP.Item No 5.1Each1638.731638.731.0FalseNoneNoneFalseNoneFalse1638.730
4081052158835Nonecode157Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and wiring complete as required. Item No 5.17 5.17.1)6-32Amps SPEach575.77575.77100.0FalseNoneNoneFalseNoneFalse57577.00
4081053158835Nonecode158Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and wiring complete as required. Item No 5.17 5.17.9 ) 40 A TPNEach2631.652631.656.0FalseNoneNoneFalseNoneFalse15789.90
4081054158835Nonecode159Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and wiring complete as required. Item No 5.17 5.17.9 ) 50-63 A TPNEach2638.862638.864.0FalseNoneNoneFalseNoneFalse10555.440
4081055158835Nonecode160GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 KgNo757.05757.052.0FalseNoneNoneFalseNoneFalse1514.10
4081056158835Nonecode161Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo708.13708.132.0FalseNoneNoneFalseNoneFalse1416.260
4081057158835Nonecode162Good Quality Salt for grounding purposes packed in 50 Kg gunny bagNo297.67297.673.0FalseNoneNoneFalseNoneFalse893.010
4081058158835Nonecode163Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specifiedNo2212.442212.441.0FalseNoneNoneFalseNoneFalse2212.440
4081059158835Nonecode164Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specifiedNo353.29353.291.0FalseNoneNoneFalseNoneFalse353.290
4081060158835Nonecode165Digging of Pit for providing GI Pipe type Earthing. In Ordinary SoilNo635.51635.511.0FalseNoneNoneFalseNoneFalse635.510
4081061158835Nonecode166Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.. Guy Wire & GI Wire as per IS-2141. 8 SWG GI Wire (4.064 mm Dia), Std Wt: 125 Kg/KMm76459.9976459.990.07FalseNoneNoneFalseNoneFalse5352.19930
4081062158835Nonecode167Supply an fixing of …feet pvc batten with integrated led tube quality diffuser with life of 25000 burning hours & 70% lumen maintance with CRIgreater than80. power input :220-240V @ 50 hz & power factor greater than.9 along with CE approved drivers. 2 years warranty. Item No 11.30 11.3.1)LED light fitting 1x2' -9/10wEach275.01275.0111.0FalseNoneNoneFalseNoneFalse3025.110
4081063158835Nonecode168Supply an fixing of …feet pvc batten with integrated led tube quality diffuser with life of 25000 burning hours & 70% lumen maintance with CRIgreater than80. power input :220-240V @ 50 hz & power factor greater than.9 along with CE approved drivers. 2 years warranty. Item No 11.30 11.3.2)LED light fitting 1x4' -20/22wEach412.0412.050.0FalseNoneNoneFalseNoneFalse20600.00
4081064158835Nonecode169Supply an fixing of …feet pvc batten with integrated led tube quality diffuser with life of 25000 burning hours & 70% lumen maintance with CRIgreater than80. power input :220-240V @ 50 hz & power factor greater than.9 along with CE approved drivers. 2 years warranty. Item No 11.5 11.5.1)LED square or round down light 5-6WEach600.49600.4910.0FalseNoneNoneFalseNoneFalse6004.90
4081065158835Nonecode170Supply an fixing of …feet pvc batten with integrated led tube quality diffuser with life of 25000 burning hours & 70% lumen maintance with CRIgreater than80. power input :220-240V @ 50 hz & power factor greater than.9 along with CE approved drivers. 2 years warranty. Item No 11.5 11.5.3)LED square or round down light 15-18WEach1374.021374.0225.0FalseNoneNoneFalseNoneFalse34350.50
4081066158835Nonecode171Supplying and fixing of round or oblong type bulk head fitting glass coverEach75.1975.195.0FalseNoneNoneFalseNoneFalse375.950
4081067158835Nonecode172Supplying exhaust fan of 1440 RPM of 300 mm (12'') size with bracket blades complete for light duty suitable for operate of 230V 50Hz, AC Supply. Item No 6.2 12" Sweep (300 mm)Each3296.03296.014.0FalseNoneNoneFalseNoneFalse46144.00
4081068158835Nonecode173Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/197.Item No 6.4 6.4.1) 48" Sweep (1200mm)Each3244.53244.540.0FalseNoneNoneFalseNoneFalse129780.00
4081069158835Nonecode174Supplying of LT UG cable having aluminium conductor PVC insulated, sheathed, galvanised, steel wire/steel tap armoured cable with PVC outer sheathing 1.1 KV class .1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Km26661.5526661.550.1FalseNoneNoneFalseNoneFalse2666.1550
4081070158835Nonecode175Supplying tinnd copper lugs and crimping and wiring to terminal point for wire of the following sizes. Heavy Duty Copper Terminal Long Barrel 50 Sqmm Copper Terminal, Apprx Wt: 26 GmNo65.9265.922.0FalseNoneNoneFalseNoneFalse131.840
4081071158835Nonecode176Supplying and fixing of heavy duty cable glands suitable or UG cable o 1.1KV class (metal only). 32 mm diaNo91.6791.672.0FalseNoneNoneFalseNoneFalse183.340
4081072158835Nonecode177Supply & fixing of aution/Danger name board as per drawingNo144.2144.21.0FalseNoneNoneFalseNoneFalse144.20
4081073158835Nonecode178Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In ordinaryCum286.34286.34112.5FalseNoneNoneFalseNoneFalse32213.250
4081074158835Nonecode179Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 MtrCum63.8663.86112.5FalseNoneNoneFalseNoneFalse7184.250
4081075158835Nonecode180Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr 57.07) PVC pipe-75mm dia (Page No 20of 40 Sl no:450)Cum156.56156.5620.0FalseNoneNoneFalseNoneFalse3131.20
4081076158835Nonecode181Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr 5.15)Supplying and fixing of Shunt trip suitable for MCCB.CBCT Item No 5.15Cum1663.451663.451.0FalseNoneNoneFalseNoneFalse1663.450
4081077158835Nonecode182Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism - Item No 5.14 5.14.14)500-630 A 50 kAEach43411.4143411.411.0FalseNoneNoneFalseNoneFalse43411.410
4081078158835Nonecode183Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism - Item No 5.14 5.14.7)100 A 25 kAEach9091.819091.814.0FalseNoneNoneFalseNoneFalse36367.240
4081079158835Nonecode184Supplying of multi function digital meter with three line back light LCD type display for voltage,Current,frequency,Power,Powerfactor,KVA,KWH,KVARsuitable for 3 Phase,4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. Item No 5.33 a)Group AEach9207.179207.178.0FalseNoneNoneFalseNoneFalse73657.360
4081080158835Nonecode185Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.y. Item No 5.14 FOUR Pole 5.14.7)50-63 A TPNEach2638.862638.866.0FalseNoneNoneFalseNoneFalse15833.160
4081081158835Nonecode186Supplying …..amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/ERP/DMC insulator which are mounted on powder coated 40x6 mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts,nuts and washers etc.,complete. Item No 5.40 5.40.4)600 A 4 x 75 x 10 mm Aluminium Stripsm5456.945456.943.0FalseNoneNoneFalseNoneFalse16370.820
4081082158835Nonecode187Supplying …..amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/ERP/DMC insulator which are mounted on powder coated 40x6 mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts,nuts and washers etc.,complete. Item No 5.40 5.40.1)100 A 4 x 75 x 10 mm Aluminium Stripsm2435.952435.952.0FalseNoneNoneFalseNoneFalse4871.90
4081083158835Nonecode188Fabricating supplying and mounting MS box made out 16 SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. Item No 5.42 5.42.1)14SWGSq CM0.470.4720000.0FalseNoneNoneFalseNoneFalse9400.00
4081084158835Nonecode189Fabricating supplying and mounting MS box made out 16 SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. Item No 5.42 5.42.2)16SWGSq CM0.420.4215000.0FalseNoneNoneFalseNoneFalse6300.00
4081085158835Nonecode190Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C.50 Hz 12/24v D.C. Item No 5.38 a)Group AEach509.85509.856.0FalseNoneNoneFalseNoneFalse3059.10
4081086158835Nonecode191Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.. Item No 5.41 5.41.1)40 x 40 x 6 mmm302.82302.824.0FalseNoneNoneFalseNoneFalse1211.280
4081087158835Nonecode192Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.. Item No 5.41 5.41.1)40 x 40 x 6 mmm37.0837.081000.0FalseNoneNoneFalseNoneFalse37080.00
4081088158835Nonecode193Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete..10KVA ON LINE UPS Two Hour back up Excluding 10x 60Ah batteriesEach130923.3130923.31.0FalseNoneNoneFalseNoneFalse130923.30
4081089158835Nonecode19412 V 60 / 65 AH capacity CAPACITY ACID BATTERYEach42528.742528.72.0FalseNoneNoneFalseNoneFalse85057.40
4081090158835Nonecode195Arrange for the 1 energy meter, CESCOM deposit, laisening work and including road cutting permission, etc.etcLS21990.521990.51.0FalseNoneNoneFalseNoneFalse21990.50
4081091158835Nonecode196Providing 4kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 6.9 Kg, empty weight 2.9 Kg, Can Height 440MM, Diameter 140MM, Discharge Time less than 13 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,8, C and electrically started Fire, A Rating 2A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete IS 15683, CE Approved. Make- ANDEX/CEASEFIRE/MINIMAX - Page No. 1, SI. No.15.3 Part-IIINo5266.85266.810.0FalseNoneNoneFalseNoneFalse52668.00
4081092158835Nonecode197Supply and installation in position, testing and commissioning 6kg Fir eEx tinguisher Mono Ammonium Phos phate Powder 50, Stored PressureType, Pressure Gauge, Gross Weight 9.5 Kg, empty weight 3.5 Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,8,C and electrically started Fire, A Rating 3A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall,,, labour, usage charges of machinery complete as per specificed.with regards to general guidelines of fire saf -Providing ABC Powder based MAP 50, 9Kg Page No. 1, SI. No.15.3 Part-IIINo3135.03135.010.0FalseNoneNoneFalseNoneFalse31350.00
4081093158835Nonecode198Supply and installation of 9kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 14.90 Kg, empty weight 5.90 Kg, Can Height 615MM, Diameter 175M M, Discharge Time less than 13Secs, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,8, C and electrically started Fire, A Rating 4A, 8 Rating 348, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power coating, Sheet metal thickness: 2.00MM, 5 years Warrantywith instalert system with Superior quality EPDM Rubber Hosepipe etc.,including including cost of supporting materials like MS stand & accessriesif it is fixing n floor / MS brackets & accessories if it is fixing onwall,including cost of supporting materials like MS stand & accessariesif ited.with regards to general guidelines of fire safety rated doors,MRLL beams, pressure switch, manual change over for doors duringemergency, ARD of 10 times with sufficie Providing ABC Powder based AP 90, 2K Page No. 1, SI. No.15.3 Part-IIINo3575.03575.05.0FalseNoneNoneFalseNoneFalse17875.00
4081094158835Nonecode199Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum105.06105.0651.84FalseNoneNoneFalseNoneFalse5446.31040
4081095158835Nonecode200Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum273.98273.9832.4FalseNoneNoneFalseNoneFalse8876.9520
4081096158835Nonecode201Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, formwork , cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6168.676168.675.0FalseNoneNoneFalseNoneFalse30843.350
4081097158835Nonecode202Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately)Cum7048.177048.1725.0FalseNoneNoneFalseNoneFalse176204.250
4081098158835Nonecode203Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11351.7311351.7336.86FalseNoneNoneFalseNoneFalse418424.76780
4081099158835Nonecode204Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ((Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately)) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Roof BeamCum10016.2410016.2412.53FalseNoneNoneFalseNoneFalse125503.48720
4081100158835Nonecode205Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ((Rate including Formwork, Centering & Scaffolding and The cost of steel reinforcement shall be paid separately)) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Roof slabCum10016.2410016.245.76FalseNoneNoneFalseNoneFalse57693.54240
4081101158835Nonecode206Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, traightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Tonne92140.7192140.7111.95FalseNoneNoneFalseNoneFalse1101081.48450
4081102158835Nonecode207Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, traightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. roof beam and slabTonne92140.7192140.713.27FalseNoneNoneFalseNoneFalse301300.12170
4081103158835Nonecode208Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside)Sqm359.47359.47195.0FalseNoneNoneFalseNoneFalse70096.650
4081104158835Nonecode209Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm160.68160.6897.5FalseNoneNoneFalseNoneFalse15666.30
4081105158835Nonecode210Providing and fixing of premium quality terracota clay tiles for cladding of size 12x2x2 inches with single hole on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification.Sqm2024.982024.9857.6FalseNoneNoneFalseNoneFalse116638.8480
4081106158835Nonecode211Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shadecm1.651.6520000.0FalseNoneNoneFalseNoneFalse33000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17273363070000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17273363070000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17273363070000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17273363070000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17273363070000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17273363080000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17273363120000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17273363210000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer (Central office), KHB, Cauvery Bhavan, K.G. Road, Bangalore Ph: 080-22273511 ext-317,None
17273363250000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if any.None
17273363300000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the e procurement Web sites only.None
17273363340000NoneNoneELIGIBILITYKHB reserves the right to withdraw or cancel this invitation to BID/Tender without assigning any reason whatsoeverNone
17273363370000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the ratesNone
17273363400000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17273363760000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17273363790000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17273363830000NoneNoneELIGIBILITYGST shall be added separately in the estimate.None
17273363860000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17273363930000NoneNoneELIGIBILITYThe bidder should maintain register of laborers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17273363970000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KHB have the right to deduct the PF amount from the work bills and remit the same to respective PF offices.None
17273364020000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to timeNone
17273364060000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund Act.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneScanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount as defined in Government order No.FD 480 EXP-12/2014,Bangalore dated:19.07.2014Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneScanned copy of Pre-qualification letter issued by Karnataka Housing Board.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of Pre-qualification letter issued by Karnataka Housing Board.
NoneNoneNoneNoneAs per Tender Documents KW-4 clause 3.3 key & critical equipments available.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Documents KW-4 clause 3.3 key & critical equipments available.
NoneNoneNoneNoneExecuted in any one Financial year, the minimum quantities of work as mentioned in tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executed in any one Financial year, the minimum quantities of work as mentioned in tender document
NoneNoneNoneNoneRequired valid electrical license for executing similar nature of work as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required valid electrical license for executing similar nature of work as per tender document
NoneNoneNoneNoneThe Tenderer should have executed similar water supply/sanitary engineering works as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
NoneNoneNoneNoneIncome Tax returns & PANFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneTo qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneScanned copy of latest GST clearance certificate.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of latest GST clearance certificate.
NoneNoneNoneNoneScanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAssessed Available Bid Capacity as per tender documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed Available Bid Capacity as per tender document
NoneNoneNoneNoneCovering letter.OthersCovering letter.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Covering letter.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Work done certificateTrueTechnical Bid
key and critical equipment LISTTrueTechnical Bid
Income Tax returns & PAN no.TrueTechnical Bid
Pre-qualification certificate issued by KHBTrueTechnical Bid
GST clearance certificateTrueTechnical Bid
Credit lines/ letter of credit/Bankers certificateTrueTechnical Bid
Assessed available tender capacity calculationTrueTechnical Bid
Electrical licenseTrueTechnical Bid
Work done certificate with quantitiesTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1727434113000
version0
createdDateNone
modifiedDateNone
blockNumberCAUVERY BHAVAN 3RD FLOOR
streetNone
cityBengaluru
stateKarnataka
pin560009
tenderRecallDTONone