1727335978000 | 0 | None | None | Buildings | Construction of laboratory/classrooms/ toilet & other allied works for Govt. First Grade College building at Shringeri in Chikkamagaluru District under state 2023-24 scheme | 11408113.86 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4080589 | 158827 | None | code01 | BLOCK-A: Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. Sl No.19.3, PageNo.187, Volume-2, FIRST FLOOR. | Cum | 4165.44 | 4165.44 | 4.72 | False | None | None | False | None | False | 19660.8768 | 0 | 4080590 | 158827 | None | code02 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. Sl No.19.7.1, PageNo.187,Volume-2, FIRST FLOOR. | Cum | 486.82 | 486.82 | 23.72 | False | None | None | False | None | False | 11547.3704 | 0 | 4080591 | 158827 | None | code03 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. Sl No.19.2.1, PageNo.187
Volume-2, FIRST FLOOR. | Cum | 1679.63 | 1679.63 | 17.2794 | False | None | None | False | None | False | 29022.998622 | 0 | 4080592 | 158827 | None | code04 | Dismantling wood work in frames, trusses, purlins and rafters upto 10 metres span and 5 metres height including stacking to the appropriate disposal area as per direction of Engineer-in-charge. Of sectional area 40 cm² and above. Sl No.19.14.1, PageNo.188
Volume-2, FIRST FLOOR. | Cum | 2967.18 | 2967.18 | 0.18 | False | None | None | False | None | False | 534.0924 | 0 | 4080593 | 158827 | None | code05 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking to the appropriate disposal area as per direction of Engineer-in-charge. Sl No.19.18, PageNo.189, Volume-2, FIRST FLOOR. | Kgs | 3.03 | 3.03 | 203.04 | False | None | None | False | None | False | 615.2112 | 0 | 4080594 | 158827 | None | code06 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material to the appropriate disposal area as per direction of Engineer-in-charge. G.S. Sheet. Sl No.19.27.1, PageNo.189, Volume-2, FIRST FLOOR. | Sqm | 110.09 | 110.09 | 33.84 | False | None | None | False | None | False | 3725.4456 | 0 | 4080595 | 158827 | None | code07 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Sl No.2.5.2, PageNo.16, Volume-I, FIRST FLOOR. COLUMN | Cum | 11749.43 | 11749.43 | 15.19 | False | None | None | False | None | False | 178473.8417 | 0 | 4080596 | 158827 | None | code08 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Sl No.2.5.2, PageNo.16, Volume-I, TERRACE FLOOR. COLUMN | Cum | 11865.76 | 11865.76 | 1.25 | False | None | None | False | None | False | 14832.2 | 0 | 4080597 | 158827 | None | code09 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates- Page 15, Sl. No.2.1.4, Volume-I, TERRACE FLOOR, DUMMY COLUMN. | Cum | 10780.28 | 10780.28 | 3.95 | False | None | None | False | None | False | 42582.106 | 0 | 4080598 | 158827 | None | code10 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Sl No.2.5.2, PageNo.16, Volume-I, BEAM, FIRST FLOOR. | Cum | 11058.29 | 11058.29 | 23.93 | False | None | None | False | None | False | 264624.8797 | 0 | 4080599 | 158827 | None | code11 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Sl No.2.5.2, PageNo.16, Volume-I, SLAB, FIRST FLOOR. | Cum | 10367.15 | 10367.15 | 60.66 | False | None | None | False | None | False | 628871.319 | 0 | 4080600 | 158827 | None | code12 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Sl No.2.5.1, PageNo.16, Volume-I, LINTEL, FIRST FLOOR. | Cum | 10714.08 | 10714.08 | 3.12 | False | None | None | False | None | False | 33427.9296 | 0 | 4080601 | 158827 | None | code13 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Sl No.2.5.1, PageNo.16, Volume-I, CHAJJA, FIRST FLOOR. | Cum | 9709.64 | 9709.64 | 5.56 | False | None | None | False | None | False | 53985.5984 | 0 | 4080602 | 158827 | None | code14 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates- Page 15, Sl. No.2.1.6, Volume-I, CILL, FIRST FLOOR. | Cum | 10088.69 | 10088.69 | 1.04 | False | None | None | False | None | False | 10492.2376 | 0 | 4080603 | 158827 | None | code15 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Sl No.2.5.2, PageNo.16, Volume-I, STAIRCASE, FIRST FLOOR. | Cum | 10367.15 | 10367.15 | 4.82 | False | None | None | False | None | False | 49969.663 | 0 | 4080604 | 158827 | None | code16 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a)Buildings- Sl. No. 2.11 , Page No.18, Volume-I, FIRST FLOOR. | Tonne | 90351.57 | 90351.57 | 15.22 | False | None | None | False | None | False | 1375150.8954 | 0 | 4080605 | 158827 | None | code17 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a)Buildings- Sl. No. 2.11 , Page No.18, Volume-I, TERRACE FLOOR. | Tonne | 91246.14 | 91246.14 | 0.64 | False | None | None | False | None | False | 58397.5296 | 0 | 4080606 | 158827 | None | code18 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl. No. 6.32 , Page No.17, Volume-II, FIRST FLOOR. | Sqm | 1323.1 | 1323.1 | 321.36 | False | None | None | False | None | False | 425191.416 | 0 | 4080607 | 158827 | None | code19 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl. No. 6.32 , Page No.17, Volume-II, TERRACE FLOOR. | Sqm | 1336.2 | 1336.2 | 47.6 | False | None | None | False | None | False | 63603.12 | 0 | 4080608 | 158827 | None | code20 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.- S.No. 6.33, Page No.17, Volume-II, FIRST FLOOR. | Sqm | 1243.31 | 1243.31 | 63.2 | False | None | None | False | None | False | 78577.192 | 0 | 4080609 | 158827 | None | code21 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.- S.No. 6.34, Page No.17, Volume-II, TERRACE FLOOR. | Sqm | 1126.08 | 1126.08 | 50.4 | False | None | None | False | None | False | 56754.432 | 0 | 4080610 | 158827 | None | code22 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.- Sl.No 12.13.1, Page No.100, Volume- II, FIRST FLOOR. | Cum | 99803.15 | 99803.15 | 0.32 | False | None | None | False | None | False | 31937.008 | 0 | 4080611 | 158827 | None | code23 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.- Sl.No 12.13.1, Page No.100, Volume- II, TERRACE FLOOR. | Cum | 100791.3 | 100791.3 | 0.11 | False | None | None | False | None | False | 11087.043 | 0 | 4080612 | 158827 | None | code24 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded
Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl.No 12.96, Page No.112, Volume- II, FIRST FLOOR. | Sqm | 6801.34 | 6801.34 | 54.0 | False | None | None | False | None | False | 367272.36 | 0 | 4080613 | 158827 | None | code25 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- Sl. No.12.85 Page No. 109, Volume-2. FIRST FLOOR. | Sqm | 5776.19 | 5776.19 | 2.4 | False | None | None | False | None | False | 13862.856 | 0 | 4080614 | 158827 | None | code26 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial. Sl. No. 12.57.6
Page No. 105,Volume-II, FIRST FLOOR. | Sqm | 3355.22 | 3355.22 | 10.8 | False | None | None | False | None | False | 36236.376 | 0 | 4080615 | 158827 | None | code27 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial. Sl. No. 12.57.6
Page No. 105,Volume-II, TERRACE FLOOR. | Sqm | 3388.44 | 3388.44 | 3.6 | False | None | None | False | None | False | 12198.384 | 0 | 4080616 | 158827 | None | code28 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding, Sl. No. 11.34A, Page No. 85, Volume-II, FIRST FLOOR. | Kgs | 169.68 | 169.68 | 902.4 | False | None | None | False | None | False | 153119.232 | 0 | 4080617 | 158827 | None | code29 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.- sl.no-12.51, pg.no-104, volume-2. | Nos | 1026.16 | 1026.16 | 4.0 | False | None | None | False | None | False | 4104.64 | 0 | 4080618 | 158827 | None | code30 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. sl.no-12.58, pg.no-105, volume-2. | Nos | 120.0 | 120.0 | 4.0 | False | None | None | False | None | False | 480.0 | 0 | 4080619 | 158827 | None | code31 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete- SL.NO-12.60, PG.NO-105, VOLUME-2. | Nos | 1052.0 | 1052.0 | 8.0 | False | None | None | False | None | False | 8416.0 | 0 | 4080620 | 158827 | None | code32 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete- SL.NO-12.62, PG.NO-105,VOLUME-2. | Nos | 237.0 | 237.0 | 8.0 | False | None | None | False | None | False | 1896.0 | 0 | 4080621 | 158827 | None | code33 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm, SL.NO-12.76.1, PG.NO-107, VOLUME-2. | Each | 435.0 | 435.0 | 8.0 | False | None | None | False | None | False | 3480.0 | 0 | 4080622 | 158827 | None | code34 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :; 125x85x5.5mm.(heavy type) Sl.no-12.75.1, pg.no-107,volume-2. | Nos | 275.0 | 275.0 | 16.0 | False | None | None | False | None | False | 4400.0 | 0 | 4080623 | 158827 | None | code35 | Providing and fixing MS Hold fasts (SL. No 444,Page No.A-25), volume-2. | Each | 50.0 | 50.0 | 24.0 | False | None | None | False | None | False | 1200.0 | 0 | 4080624 | 158827 | None | code36 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms-SL.NO-12.64, PG.NO-105,VOLUME-2. | Nos | 55.0 | 55.0 | 8.0 | False | None | None | False | None | False | 440.0 | 0 | 4080625 | 158827 | None | code37 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment. Plaster mesh 100mm wide. Sl. No. 8.16.3, Page No. 43, Volume-II, FIRST FLOOR. | m | 44.44 | 44.44 | 400.18 | False | None | None | False | None | False | 17783.9992 | 0 | 4080626 | 158827 | None | code38 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment. Plaster mesh 100mm wide. Sl. No. 8.16.3, Page No. 43, Volume-II, TERRACE FLOOR. | m | 44.88 | 44.88 | 19.2 | False | None | None | False | None | False | 861.696 | 0 | 4080627 | 158827 | None | code39 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. Sl. No. 8.10, Page No. 43, Volume-II, FIRST FLOOR CEILING.. | Sqm | 213.11 | 213.11 | 599.17 | False | None | None | False | None | False | 127689.1187 | 0 | 4080628 | 158827 | None | code40 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2. INTERNAL WALL, FIRST FLOOR, | Sqm | 369.66 | 369.66 | 468.47 | False | None | None | False | None | False | 173174.6202 | 0 | 4080629 | 158827 | None | code41 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2. INTERNAL WALL, TERRACE FLOOR, | Sqm | 373.32 | 373.32 | 48.0 | False | None | None | False | None | False | 17919.36 | 0 | 4080630 | 158827 | None | code42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2. EXTERNAL WALL, FIRST FLOOR. | Sqm | 388.85 | 388.85 | 525.07 | False | None | None | False | None | False | 204173.4695 | 0 | 4080631 | 158827 | None | code43 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2. EXTERNAL WALL, TERRACE FLOOR. | Sqm | 392.7 | 392.7 | 231.92 | False | None | None | False | None | False | 91074.984 | 0 | 4080632 | 158827 | None | code44 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. Sl.No 7.18, Page No.23, Volume-2. FIRST FLOOR. | Cum | 2037.17 | 2037.17 | 8.71 | False | None | None | False | None | False | 17743.7507 | 0 | 4080633 | 158827 | None | code45 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-Page 15, Sl. No.2.1.6, Volume-I, FIRST FLOOR. | Cum | 6305.43 | 6305.43 | 3.82 | False | None | None | False | None | False | 24086.7426 | 0 | 4080634 | 158827 | None | code46 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-Page 15, Sl. No.2.1.6, Volume-I, TERRACE FLOOR. | Cum | 6431.54 | 6431.54 | 0.84 | False | None | None | False | None | False | 5402.4936 | 0 | 4080635 | 158827 | None | code47 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and
matching pigments etc., complete..-- Size of Tile 600x600 mm. Sl.No 9.12.2, Page No.60, Volume-II, FIRST FLOOR. | Sqm | 1156.45 | 1156.45 | 204.02 | False | None | None | False | None | False | 235938.929 | 0 | 4080636 | 158827 | None | code48 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. Sl.No 9.23, Page No.63, Volume-II, FIRST FLOOR. | Sqm | 2490.66 | 2490.66 | 172.53 | False | None | None | False | None | False | 429713.5698 | 0 | 4080637 | 158827 | None | code49 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. Sl.No 9.30, Page No.64
Volume-II, FIRST FLOOR | Sqm | 5381.28 | 5381.28 | 28.57 | False | None | None | False | None | False | 153743.1696 | 0 | 4080638 | 158827 | None | code50 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2. FIRST FLOOR. | Sqm | 101.0 | 101.0 | 1067.64 | False | None | None | False | None | False | 107831.64 | 0 | 4080639 | 158827 | None | code51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2. TERRACE FLOOR. | Sqm | 101.0 | 101.0 | 48.0 | False | None | None | False | None | False | 4848.0 | 0 | 4080640 | 158827 | None | code52 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2. CEILING, FIRST FLOOR. | Sqm | 159.58 | 159.58 | 599.17 | False | None | None | False | None | False | 95615.5486 | 0 | 4080641 | 158827 | None | code53 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) Sl.No 8.33.1
Page No.46, Volume-II, INTERNAL WALL, FIRST FLOOR. | Sqm | 159.58 | 159.58 | 468.47 | False | None | None | False | None | False | 74758.4426 | 0 | 4080642 | 158827 | None | code54 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) Sl.No 8.33.1
Page No.46, Volume-II, INTERNAL WALL, TERRACE FLOOR. | Sqm | 161.16 | 161.16 | 48.0 | False | None | None | False | None | False | 7735.68 | 0 | 4080643 | 158827 | None | code55 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2. EXTERNAL WALL, FIRST FLOOR. | Sqm | 175.74 | 175.74 | 525.07 | False | None | None | False | None | False | 92275.8018 | 0 | 4080644 | 158827 | None | code56 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2. EXTERNAL WALL, TERRACE FLOOR. | Sqm | 177.48 | 177.48 | 231.92 | False | None | None | False | None | False | 41161.1616 | 0 | 4080645 | 158827 | None | code57 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.29, Page No.45, Volume-II, FIRST FLOOR. | Sqm | 285.83 | 285.83 | 10.5 | False | None | None | False | None | False | 3001.215 | 0 | 4080646 | 158827 | None | code58 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2. FIRTS FLOOR. | Sqm | 168.67 | 168.67 | 56.4 | False | None | None | False | None | False | 9512.988 | 0 | 4080647 | 158827 | None | code59 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.50, Volume-2. FIRST FLOOR. | Sqm | 56.56 | 56.56 | 28.08 | False | None | None | False | None | False | 1588.2048 | 0 | 4080648 | 158827 | None | code60 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.50, Volume-2. TERRACE FLOOR. | Sqm | 57.12 | 57.12 | 9.36 | False | None | None | False | None | False | 534.6432 | 0 | 4080649 | 158827 | None | code61 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49,volume-2. FIRST FLOOR. | Sqm | 136.35 | 136.35 | 28.08 | False | None | None | False | None | False | 3828.708 | 0 | 4080650 | 158827 | None | code62 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49,volume-2. TERRACE FLOOR. | Sqm | 137.7 | 137.7 | 9.36 | False | None | None | False | None | False | 1288.872 | 0 | 4080651 | 158827 | None | code63 | Providing and fixing ion wall face unplasticised Rigid PVC rain water pipes confirming to IS :13592 Type A,including jointing with seal ring confirming to IS:5382,leaving 10mm gap for thermal expansion,(i) Single socketed pipes 100mm diameter.item no-13.48, volume-2. PG.NO-125. | m | 293.91 | 293.91 | 64.4 | False | None | None | False | None | False | 18927.804 | 0 | 4080652 | 158827 | None | code64 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.16.2, Page No.82, Volume-2. TERRACE FLOOR. | Kgs | 149.94 | 149.94 | 203.04 | False | None | None | False | None | False | 30443.8176 | 0 | 4080653 | 158827 | None | code65 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-
charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Sl.No 7.38, Page No.26, Volume-2. TERRACE FLOOR. | Sqm | 579.36 | 579.36 | 33.84 | False | None | None | False | None | False | 19605.5424 | 0 | 4080654 | 158827 | None | code66 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Page 15, Sl. No.2.1.4, Volume-I, TERRACE FLOOR. | Cum | 6341.34 | 6341.34 | 20.22 | False | None | None | False | None | False | 128221.8948 | 0 | 4080655 | 158827 | None | code67 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin- Charge. (Sl.no-8.12, pg.no-43, volume-2.) TERRACE FLOOR. | Sqm | 457.98 | 457.98 | 404.37 | False | None | None | False | None | False | 185193.3726 | 0 | 4080656 | 158827 | None | code68 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sl.No 11.28, Page No.85, Volume-2. FIRST FLOOR. | Kgs | 453.49 | 453.49 | 58.2 | False | None | None | False | None | False | 26393.118 | 0 | 4080657 | 158827 | None | code69 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. Page 54, Sl. No.8.79, Volume-2, TERRACE FLOOR. | m | 53.04 | 53.04 | 247.0 | False | None | None | False | None | False | 13100.88 | 0 | 4080658 | 158827 | None | code70 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. Page 149, Sl. No.15.1, Volume-2, TERRACE FLOOR. | Sqm | 825.17 | 825.17 | 6.0 | False | None | None | False | None | False | 4951.02 | 0 | 4080659 | 158827 | None | code71 | BLOCK-B: Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. Sl No.19.3, PageNo.187, Volume-2, FIRST FLOOR. | Cum | 4165.44 | 4165.44 | 2.59 | False | None | None | False | None | False | 10788.4896 | 0 | 4080660 | 158827 | None | code72 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. Sl No.19.7.1, PageNo.187, Volume-2, FIRST FLOOR. | Cum | 486.82 | 486.82 | 9.57 | False | None | None | False | None | False | 4658.8674 | 0 | 4080661 | 158827 | None | code73 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. Sl No.19.2.1, PageNo.187
Volume-2, FIRST FLOOR. | Cum | 1679.63 | 1679.63 | 9.46 | False | None | None | False | None | False | 15889.2998 | 0 | 4080662 | 158827 | None | code74 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Sl No.2.5.2, PageNo.16, Volume-I, COLUMN, FIRST FLOOR. | Cum | 11749.43 | 11749.43 | 9.53 | False | None | None | False | None | False | 111972.0679 | 0 | 4080663 | 158827 | None | code75 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates- Page 15, Sl. No.2.1.4, Volume-I, DUMMY COLUMN, TERRACE FLOOR. | Cum | 10780.28 | 10780.28 | 2.48 | False | None | None | False | None | False | 26735.0944 | 0 | 4080664 | 158827 | None | code76 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Sl No.2.5.2, PageNo.16,Volume-I, BEAM, FIRST FLOOR. | Cum | 11058.29 | 11058.29 | 15.8 | False | None | None | False | None | False | 174720.982 | 0 | 4080665 | 158827 | None | code77 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Sl No.2.5.2, PageNo.16, Volume-I, SLAB, FIRST FLOOR. | Cum | 10367.15 | 10367.15 | 35.76 | False | None | None | False | None | False | 370729.284 | 0 | 4080666 | 158827 | None | code78 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Sl No.2.5.1, PageNo.16, Volume-I, LINTEL, FIRST FLOOR. | Cum | 10714.08 | 10714.08 | 3.02 | False | None | None | False | None | False | 32356.5216 | 0 | 4080667 | 158827 | None | code79 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Sl No.2.5.1, PageNo.16, Volume-I, CHAJJA, FIRST FLOOR. | Cum | 9709.64 | 9709.64 | 0.97 | False | None | None | False | None | False | 9418.3508 | 0 | 4080668 | 158827 | None | code80 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates- Page 15, Sl. No.2.1.6, Volume-I, CILL, FIRST FLOOR. | Cum | 10088.69 | 10088.69 | 0.73 | False | None | None | False | None | False | 7364.7437 | 0 | 4080669 | 158827 | None | code81 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a)Buildings- Sl. No. 2.11 , Page No.18,Volume-I, FIRST FLOOR. | Tonne | 90351.57 | 90351.57 | 8.99 | False | None | None | False | None | False | 812260.6143 | 0 | 4080670 | 158827 | None | code82 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a)Buildings- Sl. No. 2.11 , Page No.18,Volume-I, TERRACE FLOOR. | Tonne | 91246.14 | 91246.14 | 0.25 | False | None | None | False | None | False | 22811.535 | 0 | 4080671 | 158827 | None | code83 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl. No. 6.32 , Page No.17,Volume-II, FIRST FLOOR. | Sqm | 1323.1 | 1323.1 | 234.84 | False | None | None | False | None | False | 310716.804 | 0 | 4080672 | 158827 | None | code84 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.- S.No. 6.33, Page No.17,Volume-II, FIRST FLOOR. | Sqm | 1243.31 | 1243.31 | 36.75 | False | None | None | False | None | False | 45691.6425 | 0 | 4080673 | 158827 | None | code85 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.- S.No. 6.34, Page No.17,Volume-II, TERRACE FLOOR. | Sqm | 1126.08 | 1126.08 | 34.2 | False | None | None | False | None | False | 38511.936 | 0 | 4080674 | 158827 | None | code86 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.- Sl.No 12.13.1, Page No.100, Volume- II, FIRST FLOOR. | Cum | 99803.15 | 99803.15 | 0.42 | False | None | None | False | None | False | 41917.323 | 0 | 4080675 | 158827 | None | code87 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of
elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge.
(Fixtures shall be paid for separately) Size 62 x 125mm. Sl.No 12.93.2, Page No.111, Volume- II, FIRST FLOOR. | m | 771.64 | 771.64 | 19.2 | False | None | None | False | None | False | 14815.488 | 0 | 4080676 | 158827 | None | code88 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with
Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded
Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl.No 12.96, Page No.112, Volume- II, FIRST FLOOR. | Sqm | 6801.34 | 6801.34 | 21.6 | False | None | None | False | None | False | 146908.944 | 0 | 4080677 | 158827 | None | code89 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- Sl. No.12.85 Page No. 109, Volume-2. FIRST FLOOR. | Sqm | 5776.19 | 5776.19 | 5.22 | False | None | None | False | None | False | 30151.7118 | 0 | 4080678 | 158827 | None | code90 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial. Sl. No. 12.57.6, Page No. 105,
Volume-II, FIRST FLOOR. | Sqm | 3355.22 | 3355.22 | 14.4 | False | None | None | False | None | False | 48315.168 | 0 | 4080679 | 158827 | None | code91 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness. Sl. No. 12.94.1, Page No. 112,Volume-II. FIRST FLOOR. | Sqm | 3519.85 | 3519.85 | 5.4 | False | None | None | False | None | False | 19007.19 | 0 | 4080680 | 158827 | None | code92 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding, Sl. No. 11.34A, Page No. 85,Volume-II, FIRST FLOOR. | Kgs | 169.68 | 169.68 | 429.12 | False | None | None | False | None | False | 72813.0816 | 0 | 4080681 | 158827 | None | code93 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.- sl.no-12.51, pg.no-104, volume-2. | Nos | 1026.16 | 1026.16 | 7.0 | False | None | None | False | None | False | 7183.12 | 0 | 4080682 | 158827 | None | code94 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. sl.no-12.58, pg.no-105, volume-2. | Nos | 120.0 | 120.0 | 7.0 | False | None | None | False | None | False | 840.0 | 0 | 4080683 | 158827 | None | code95 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete- SL.NO-12.60, PG.NO-105, VOLUME-2. | Nos | 1052.0 | 1052.0 | 14.0 | False | None | None | False | None | False | 14728.0 | 0 | 4080684 | 158827 | None | code96 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete- SL.NO-12.62, PG.NO-105,VOLUME-2. | Nos | 237.0 | 237.0 | 14.0 | False | None | None | False | None | False | 3318.0 | 0 | 4080685 | 158827 | None | code97 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm, SL.NO-12.76.1, PG.NO-107, VOLUME-2. | Each | 435.0 | 435.0 | 14.0 | False | None | None | False | None | False | 6090.0 | 0 | 4080686 | 158827 | None | code98 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5mm.(heavy type) Sl.no-12.75.1, pg.no-107,volume-2. | Nos | 275.0 | 275.0 | 28.0 | False | None | None | False | None | False | 7700.0 | 0 | 4080687 | 158827 | None | code99 | Providing and fixing MS Hold fasts (SL. No 444,Page No.A-25), volume-2. | Each | 50.0 | 50.0 | 42.0 | False | None | None | False | None | False | 2100.0 | 0 | 4080688 | 158827 | None | code100 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms-SL.NO-12.64, PG.NO-105,VOLUME-2. | Nos | 55.0 | 55.0 | 14.0 | False | None | None | False | None | False | 770.0 | 0 | 4080689 | 158827 | None | code101 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment. Plaster mesh 100mm wide. Sl. No. 8.16.3, Page No. 43,,Volume-II, FIRST FLOOR. | m | 44.44 | 44.44 | 309.0 | False | None | None | False | None | False | 13731.96 | 0 | 4080690 | 158827 | None | code102 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment. Plaster mesh 100mm wide. Sl. No. 8.16.3, Page No. 43,,Volume-II, TERRACE FLOOR. | m | 44.88 | 44.88 | 19.2 | False | None | None | False | None | False | 861.696 | 0 | 4080691 | 158827 | None | code103 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. Sl. No. 8.10,Page No. 43,Volume-II, FIRST FLOOR. CEILING. | Sqm | 213.11 | 213.11 | 304.28 | False | None | None | False | None | False | 64845.1108 | 0 | 4080692 | 158827 | None | code104 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2. FIRST FLOOR INTERNAL WALL.. | Sqm | 369.66 | 369.66 | 234.87 | False | None | None | False | None | False | 86822.0442 | 0 | 4080693 | 158827 | None | code105 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2. FIRST FLOOR. EXTERNAL WALL. | Sqm | 388.85 | 388.85 | 421.33 | False | None | None | False | None | False | 163834.1705 | 0 | 4080694 | 158827 | None | code106 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2. TERRACE FLOOR. EXTERNAL WALL. | Sqm | 392.7 | 392.7 | 116.07 | False | None | None | False | None | False | 45580.689 | 0 | 4080695 | 158827 | None | code107 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41, Volume- 2. FIRST FLOOR. | Sqm | 297.95 | 297.95 | 112.06 | False | None | None | False | None | False | 33388.277 | 0 | 4080696 | 158827 | None | code108 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. Sl.No. 8.16a, Page No.44, Volume- II, FIRST FLOOR. | Sqm | 1250.38 | 1250.38 | 1.6 | False | None | None | False | None | False | 2000.608 | 0 | 4080697 | 158827 | None | code109 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. Sl.No 7.18, Page No.23, Volume-2.FIRST FLOOR. | Cum | 2037.17 | 2037.17 | 16.35 | False | None | None | False | None | False | 33307.7295 | 0 | 4080698 | 158827 | None | code110 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-Page 15, Sl. No.2.1.6, Volume-I, FIRST FLOOR. | Cum | 6305.43 | 6305.43 | 6.22 | False | None | None | False | None | False | 39219.7746 | 0 | 4080699 | 158827 | None | code111 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-Page 15, Sl. No.2.1.6, Volume-I, TERRACE FLOOR. | Cum | 6431.54 | 6431.54 | 0.57 | False | None | None | False | None | False | 3665.9778 | 0 | 4080700 | 158827 | None | code112 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and
matching pigments etc., complete..-- Size of Tile 600x600 mm. Sl.No 9.12.2, Page No.60, Volume-II, FIRST FLOOR. | Sqm | 1156.45 | 1156.45 | 108.76 | False | None | None | False | None | False | 125775.502 | 0 | 4080701 | 158827 | None | code113 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. Sl.No 9.23, Page No.63,Volume-II, FIRST FLOOR. | Sqm | 2490.66 | 2490.66 | 49.47 | False | None | None | False | None | False | 123212.9502 | 0 | 4080702 | 158827 | None | code114 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. Sl.No 9.9, Page No.60
Volume-II, FIRST FLOOR. | Sqm | 1086.76 | 1086.76 | 30.24 | False | None | None | False | None | False | 32863.6224 | 0 | 4080703 | 158827 | None | code115 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71, Volume-2. FIRST FLOOR. | Sqm | 1117.06 | 1117.06 | 112.06 | False | None | None | False | None | False | 125177.7436 | 0 | 4080704 | 158827 | None | code116 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2. FIRST FLOOR. | Sqm | 101.0 | 101.0 | 539.15 | False | None | None | False | None | False | 54454.15 | 0 | 4080705 | 158827 | None | code117 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2. CEILING, FIRST FLOOR. | Sqm | 159.58 | 159.58 | 304.28 | False | None | None | False | None | False | 48557.0024 | 0 | 4080706 | 158827 | None | code118 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) Sl.No 8.33.1, Page No.46
Volume-II, INTERNAL WALL, FIRST FLOOR. | Sqm | 159.58 | 159.58 | 234.87 | False | None | None | False | None | False | 37480.5546 | 0 | 4080707 | 158827 | None | code119 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2. EXTERNAL WALL, FIRST FLOOR. | Sqm | 175.74 | 175.74 | 421.33 | False | None | None | False | None | False | 74044.5342 | 0 | 4080708 | 158827 | None | code120 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2. EXTERNAL WALL, TERRACE FLOOR. | Sqm | 177.48 | 177.48 | 116.07 | False | None | None | False | None | False | 20600.1036 | 0 | 4080709 | 158827 | None | code121 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.29, Page No.45, Volume-II, FIRST FLOOR. | Sqm | 285.83 | 285.83 | 8.43 | False | None | None | False | None | False | 2409.5469 | 0 | 4080710 | 158827 | None | code122 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2. FIRST FLOOR. | Sqm | 168.67 | 168.67 | 26.82 | False | None | None | False | None | False | 4523.7294 | 0 | 4080711 | 158827 | None | code123 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.50, Volume-2. FIRST FLOOR. | Sqm | 56.56 | 56.56 | 37.44 | False | None | None | False | None | False | 2117.6064 | 0 | 4080712 | 158827 | None | code124 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49,volume-2. FIRST FLOOR. | Sqm | 136.35 | 136.35 | 37.44 | False | None | None | False | None | False | 5104.944 | 0 | 4080713 | 158827 | None | code125 | Providing and fixing ion wall face unplasticised Rigid PVC rain water pipes confirming to IS :13592 Type A,including jointing with seal ring confirming to IS:5382,leaving 10mm gap for thermal expansion,(i) Single socketed pipes 100mm diameter.item no-13.48, volume-2. PG.NO-125. | m | 293.91 | 293.91 | 44.0 | False | None | None | False | None | False | 12932.04 | 0 | 4080714 | 158827 | None | code126 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Page 15, Sl. No.2.1.4, Volume-I, TERRACE FLOOR. | Cum | 6341.34 | 6341.34 | 11.92 | False | None | None | False | None | False | 75588.7728 | 0 | 4080715 | 158827 | None | code127 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin- Charge. (Sl.no-8.12, pg.no-43, volume-2.) TERRACE FLOOR. | Sqm | 457.98 | 457.98 | 238.43 | False | None | None | False | None | False | 109196.1714 | 0 | 4080716 | 158827 | None | code128 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. Page 54, Sl. No.8.79, Volume-2, TERRACE FLOOR. | m | 53.04 | 53.04 | 186.0 | False | None | None | False | None | False | 9865.44 | 0 | 4080717 | 158827 | None | code129 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing
membrane. The finished cost to include surface preparation,
making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. Page 149, Sl. No.15.1, Volume-2, TERRACE FLOOR. | Sqm | 825.17 | 825.17 | 4.0 | False | None | None | False | None | False | 3300.68 | 0 | 4080718 | 158827 | None | code130 | INTERNAL WIRING & POWER POINTS: PVC Conduit and its Accessories: Concealed Conduit System: Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory: 19/20mm Dia 2mm Thick, SL.NO-1.2.1 | m | 66.0 | 66.0 | 350.0 | False | None | None | False | None | False | 23100.0 | 0 | 4080719 | 158827 | None | code131 | INTERNAL WIRING & POWER POINTS: PVC Conduit and its Accessories: Concealed Conduit System: Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory: 25mm dia 2mm Thick, SL.NO-1.2.2 | m | 78.0 | 78.0 | 450.0 | False | None | None | False | None | False | 35100.0 | 0 | 4080720 | 158827 | None | code132 | INTERNAL WIRING & POWER POINTS: : Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory: 19/20mm Dia 2mm Thick, SL.NO-1.3.1 | m | 75.0 | 75.0 | 350.0 | False | None | None | False | None | False | 26250.0 | 0 | 4080721 | 158827 | None | code133 | INTERNAL WIRING & POWER POINTS: : Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory: 25mm dia 2mm Thick, SL.NO-1.3.2. | m | 80.0 | 80.0 | 450.0 | False | None | None | False | None | False | 36000.0 | 0 | 4080722 | 158827 | None | code134 | Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes: 19/20 mm Deep Junction Box, SL.NO-1.5.1 | Each | 49.0 | 49.0 | 50.0 | False | None | None | False | None | False | 2450.0 | 0 | 4080723 | 158827 | None | code135 | Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes: 25 mm Deep Junction Box, SL.NO-1.5.2. | Each | 51.0 | 51.0 | 30.0 | False | None | None | False | None | False | 1530.0 | 0 | 4080724 | 158827 | None | code136 | Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc: 20 mm, SL.NO-1.8.1. | m | 28.0 | 28.0 | 200.0 | False | None | None | False | None | False | 5600.0 | 0 | 4080725 | 158827 | None | code137 | Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc: 25 mm, SL.NO-1.8.2. | m | 35.0 | 35.0 | 200.0 | False | None | None | False | None | False | 7000.0 | 0 | 4080726 | 158827 | None | code138 | Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly: 20 mm, SL.NO-1.9.1. | m | 19.0 | 19.0 | 25.0 | False | None | None | False | None | False | 475.0 | 0 | 4080727 | 158827 | None | code139 | Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly: 25 mm, SL.NO-1.9.2. | m | 22.0 | 22.0 | 25.0 | False | None | None | False | None | False | 550.0 | 0 | 4080728 | 158827 | None | code140 | Supply & Fixing of Metal fan box with round Hook, SL.NO-1.12. | Each | 117.0 | 117.0 | 25.0 | False | None | None | False | None | False | 2925.0 | 0 | 4080729 | 158827 | None | code141 | Wires & Cables: Point wiring using copper wire without Switch: Make : KEI / Polycab/ Finolex: Short point upto 3 Mtd. From Tapping point to outlet via switch box. SL.NO-2.2.1 | Point | 269.0 | 269.0 | 10.0 | False | None | None | False | None | False | 2690.0 | 0 | 4080730 | 158827 | None | code142 | Wires & Cables: Point wiring using copper wire without Switch: Make : KEI / Polycab/ Finolex: Medium point above 3 Mts upto 6 Mts. From tapping point to outlet via switch box. SL.NO-2.2.2. | Point | 379.0 | 379.0 | 40.0 | False | None | None | False | None | False | 15160.0 | 0 | 4080731 | 158827 | None | code143 | Wires & Cables: Point wiring using copper wire without Switch: Make : KEI / Polycab/ Finolex: Long point above 6 Mts. Upto 10 Mts. From tapping of point to outlet via switch box. SL.NO-2.2.3. | Point | 555.0 | 555.0 | 35.0 | False | None | None | False | None | False | 19425.0 | 0 | 4080732 | 158827 | None | code144 | Wires & Cables: Point wiring using copper wire without Switch: Make : KEI / Polycab/ Finolex: Two outlet in a row above 3 Mts upto 6 Mts, from tapping point to outlet via switch box. SL.NO-2.2.4. | Point | 677.0 | 677.0 | 20.0 | False | None | None | False | None | False | 13540.0 | 0 | 4080733 | 158827 | None | code145 | Wires & Cables: Point wiring using copper wire without Switch: Make : KEI / Polycab/ Finolex: Three outlet in a row, above 6 Mts. Upto 10 Mts. From tapping point to outlet via switch box. SL.NO-2.2.5. | Point | 989.0 | 989.0 | 20.0 | False | None | None | False | None | False | 19780.0 | 0 | 4080734 | 158827 | None | code146 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 1.5 Sqmm, SL.NO-2.3.2. | m | 26.0 | 26.0 | 1000.0 | False | None | None | False | None | False | 26000.0 | 0 | 4080735 | 158827 | None | code147 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 2.5Sqmm, SL.NO-2.3.3. | m | 42.0 | 42.0 | 2000.0 | False | None | None | False | None | False | 84000.0 | 0 | 4080736 | 158827 | None | code148 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 4Sqmm, SL.NO-2.3.4. | m | 63.0 | 63.0 | 400.0 | False | None | None | False | None | False | 25200.0 | 0 | 4080737 | 158827 | None | code149 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 6 sqmm , SL.NO-2.3.5. | m | 92.0 | 92.0 | 100.0 | False | None | None | False | None | False | 9200.0 | 0 | 4080738 | 158827 | None | code150 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 10Sqmm, SL.NO-2.3.6. | m | 167.0 | 167.0 | 50.0 | False | None | None | False | None | False | 8350.0 | 0 | 4080739 | 158827 | None | code151 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 16Sqmm, SL.NO-2.3.7. | m | 318.0 | 318.0 | 50.0 | False | None | None | False | None | False | 15900.0 | 0 | 4080740 | 158827 | None | code152 | Switches Sockets and Accessories : Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand: 1-3 way , sl.no-3.4.1. | Each | 138.0 | 138.0 | 25.0 | False | None | None | False | None | False | 3450.0 | 0 | 4080741 | 158827 | None | code153 | Switches Sockets and Accessories : Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand; 4-5 way, sl.no-3.4.2. | Each | 177.0 | 177.0 | 10.0 | False | None | None | False | None | False | 1770.0 | 0 | 4080742 | 158827 | None | code154 | Switches Sockets and Accessories : Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand: 6 way, sl.no-3.4.3. | Each | 220.0 | 220.0 | 80.0 | False | None | None | False | None | False | 17600.0 | 0 | 4080743 | 158827 | None | code155 | Switches Sockets and Accessories : Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand; 8 way , sl.no-3.4.4. | Each | 261.0 | 261.0 | 2.0 | False | None | None | False | None | False | 522.0 | 0 | 4080744 | 158827 | None | code156 | Switches Sockets and Accessories : Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand: 12 way, sl.no-3.4.5. | Each | 319.0 | 319.0 | 4.0 | False | None | None | False | None | False | 1276.0 | 0 | 4080745 | 158827 | None | code157 | Switches Sockets and Accessories : Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand: 16 way , sl.no-3.4.6. | Each | 363.0 | 363.0 | 1.0 | False | None | None | False | None | False | 363.0 | 0 | 4080746 | 158827 | None | code158 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box; 1-3 way , sl.no-3.5.1. | Each | 161.0 | 161.0 | 25.0 | False | None | None | False | None | False | 4025.0 | 0 | 4080747 | 158827 | None | code159 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 4-5 way, sl.no-3.5.2. | Each | 175.0 | 175.0 | 10.0 | False | None | None | False | None | False | 1750.0 | 0 | 4080748 | 158827 | None | code160 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 6 way, sl.no-3.5.3. | Each | 234.0 | 234.0 | 80.0 | False | None | None | False | None | False | 18720.0 | 0 | 4080749 | 158827 | None | code161 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 8 way , sl.no-3.5.4. | Each | 284.0 | 284.0 | 2.0 | False | None | None | False | None | False | 568.0 | 0 | 4080750 | 158827 | None | code162 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 10-12 way, sl.no-3.5.5. | Each | 344.0 | 344.0 | 4.0 | False | None | None | False | None | False | 1376.0 | 0 | 4080751 | 158827 | None | code163 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 16 way , sl.no-3.5.6. | Each | 397.0 | 397.0 | 1.0 | False | None | None | False | None | False | 397.0 | 0 | 4080752 | 158827 | None | code164 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate: 6 Amp one way , sl.no-3.6.1. | Each | 102.0 | 102.0 | 155.0 | False | None | None | False | None | False | 15810.0 | 0 | 4080753 | 158827 | None | code165 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate: 6 Amps 2 way, sl.no-3.6.2. | Each | 166.0 | 166.0 | 4.0 | False | None | None | False | None | False | 664.0 | 0 | 4080754 | 158827 | None | code166 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate; 6 Amps socket, sl.no-3.6.3. | Each | 171.0 | 171.0 | 30.0 | False | None | None | False | None | False | 5130.0 | 0 | 4080755 | 158827 | None | code167 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate: Stepped Fan Regulator, sl.no-3.6.4 | Each | 357.0 | 357.0 | 20.0 | False | None | None | False | None | False | 7140.0 | 0 | 4080756 | 158827 | None | code168 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate: 16 Amps 1 way switch, sl.no-3.6.8. | Each | 180.0 | 180.0 | 160.0 | False | None | None | False | None | False | 28800.0 | 0 | 4080757 | 158827 | None | code169 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate: 6 Amps Bell Push, sl.no-3.7.9 | Each | 177.0 | 177.0 | 1.0 | False | None | None | False | None | False | 177.0 | 0 | 4080758 | 158827 | None | code170 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate: 32 Amps DP Switch, sl.no-3.7.10. | Each | 326.0 | 326.0 | 5.0 | False | None | None | False | None | False | 1630.0 | 0 | 4080759 | 158827 | None | code171 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate: 6/16 Amps universal socket, sl.no-3.6.11. | Each | 236.0 | 236.0 | 160.0 | False | None | None | False | None | False | 37760.0 | 0 | 4080760 | 158827 | None | code172 | LUMINERIES & LIGHT FIXTURES & ACCESSORIES: Make : Panasonic/Phillips / Crompton: Led Light Fixture 2 feet - 9/10 W, sl.no-11.3.1. | Each | 551.0 | 551.0 | 6.0 | False | None | None | False | None | False | 3306.0 | 0 | 4080761 | 158827 | None | code173 | LUMINERIES & LIGHT FIXTURES & ACCESSORIES: Make : Panasonic/Phillips / Crompton: Led Light Fixture 4 feet - 20/22 W, sl.no-11.3.2. | Each | 690.0 | 690.0 | 70.0 | False | None | None | False | None | False | 48300.0 | 0 | 4080762 | 158827 | None | code174 | PANEL & DISTRIBUTION BOARDS; Distribution boards: Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting : Double Door: 8Way SP &N, sl.no- 5.18.8. | Nos | 1854.0 | 1854.0 | 1.0 | False | None | None | False | None | False | 1854.0 | 0 | 4080763 | 158827 | None | code175 | PANEL & DISTRIBUTION BOARDS; Distribution boards: Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting : Double Door: 12Way SP &N, sl.no- 5.18.9. | Nos | 2329.0 | 2329.0 | 1.0 | False | None | None | False | None | False | 2329.0 | 0 | 4080764 | 158827 | None | code176 | PANEL & DISTRIBUTION BOARDS; Distribution boards: Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting : Double Door: 8Way TP &N sl.no- 5.18.13. | Nos | 6091.0 | 6091.0 | 1.0 | False | None | None | False | None | False | 6091.0 | 0 | 4080765 | 158827 | None | code177 | Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board: 32 - 40 Amps 2 pole, sl.no-5.20.2. | Nos | 4559.0 | 4559.0 | 3.0 | False | None | None | False | None | False | 13677.0 | 0 | 4080766 | 158827 | None | code178 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898: 5 - 32 Amp SP, sl.no-5.17.1. | Nos | 415.0 | 415.0 | 24.0 | False | None | None | False | None | False | 9960.0 | 0 | 4080767 | 158827 | None | code179 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898: 5 - 32 Amp DP, sl.no-5.17.4. | Nos | 739.0 | 739.0 | 3.0 | False | None | None | False | None | False | 2217.0 | 0 | 4080768 | 158827 | None | code180 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898: 40 - 63 Amp TPN, sl.no-5.17.9. | Nos | 3088.0 | 3088.0 | 2.0 | False | None | None | False | None | False | 6176.0 | 0 | 4080769 | 158827 | None | code181 | SERVICE MAINS & WORK UNDER UG CABLE , EARTHING: Supplying Fixing and Wiring earth electrode for grounding of lifts,Xmer, DG Sets etc using 40mm dia 2.9mm thick, 2.5mtr long GI pipe with GI funnel with mesh & suitable size reducer fixed on the top of Electrode. The funnel should be enclosed in a cc chamber of 400x400x400 with a cast iron cover. The Earth electrode shall have staggered holes of 12mm dia & electrode shoulde be covered 150mm around with alternate layers of salt & charcoal from the bottom of the CC Chamber. The connection from the electrode is to be established throgh GI strip using GI bolts & nuts. | Nos | 4150.0 | 4150.0 | 2.0 | False | None | None | False | None | False | 8300.0 | 0 | 4080770 | 158827 | None | code182 | Supplying & running of GI/Cu. Strips for gr ounding connections using necessary fixing material as required….. GI Strip ; 25 x 3 mm G.I strip. SL.NO-6.3.1 | m | 75.0 | 75.0 | 50.0 | False | None | None | False | None | False | 3750.0 | 0 | 4080771 | 158827 | None | code183 | Supplying & running of GI/Cu. Strips for gr ounding connections using necessary fixing material as required….. GI Strip ; 600x600x3 GI Plate SL.NO-6.3.5. | Each | 760.0 | 760.0 | 2.0 | False | None | None | False | None | False | 1520.0 | 0 | 4080772 | 158827 | None | code184 | Supplying & running of GI/Cu. Strips for gr ounding connections using necessary fixing material as required….. Cu Strip ; 25 x 3 mm SL.NO-6.3.6. | m | 505.0 | 505.0 | 50.0 | False | None | None | False | None | False | 25250.0 | 0 | 4080773 | 158827 | None | code185 | Supplying & running of GI/Cu. Strips for gr ounding connections using necessary fixing material as required….. Cu Strip ;600x600x3 Cu. Plate, SL.NO-6.3.10. | Each | 6900.0 | 6900.0 | 2.0 | False | None | None | False | None | False | 13800.0 | 0 | 4080774 | 158827 | None | code186 | FANS & AIR CONDITIONERS; Make Fans : Crompton / Usha / Anchor : Supplying exhaust fan 0f 1440 RPM of300 mm (12") size with bracket blades complte for light duty suitable to operate on 230V 50 Hz AC Supply, sl.no-6.1. | Each | 1492.0 | 1492.0 | 4.0 | False | None | None | False | None | False | 5968.0 | 0 | 4080775 | 158827 | None | code187 | FANS & AIR CONDITIONERS; Make Fans : Crompton / Usha / Anchor : 48 " Sweep Economy model, sl.no-6.3.1. | Each | 2677.0 | 2677.0 | 25.0 | False | None | None | False | None | False | 66925.0 | 0 | 4080776 | 158827 | None | code188 | UPS & BATTERIES: Make : Emerson / APC: 2KVA offline UPS, sl.no-9.2.3. | Nos | 21293.0 | 21293.0 | 3.0 | False | None | None | False | None | False | 63879.0 | 0 | 4080777 | 158827 | None | code189 | UPS & BATTERIES: Make : Emerson / APC; 150 AH capacity, sl.no-9.5.9. | Nos | 15895.0 | 15895.0 | 3.0 | False | None | None | False | None | False | 47685.0 | 0 | 4080778 | 158827 | None | code190 | INTERCOM AND TV CABLING: Make : Amp / D link / Systimax: Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. andfixing using invetred wood plugs in Case of RCC ceiling and RCC wall /stone structure or rawl plug incase of brick walls and cement plastering the damaged portion using heavy guage saddles in an intervel of 700 mm using NF Screws: 19/20mm Dia 2mm Thick, sl.no-1.1.1. | m | 69.0 | 69.0 | 250.0 | False | None | None | False | None | False | 17250.0 | 0 | 4080779 | 158827 | None | code191 | INTERCOM AND TV CABLING: Make : Amp / D link / Systimax: Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. andfixing using invetred wood plugs in Case of RCC ceiling and RCC wall /stone structure or rawl plug incase of brick walls and cement plastering the damaged portion using heavy guage saddles in an intervel of 700 mm using NF Screws; 25mm dia 2mm Thick, sl.no-1.1.2. | m | 81.0 | 81.0 | 300.0 | False | None | None | False | None | False | 24300.0 | 0 | 4080780 | 158827 | None | code192 | Supplying and drawing pvc insulated gas injected physical foam jelly filled co axial TV Cable Rg6: Supplying & drawing UTP Cat 6 E Lan Cable, sl.no-8.1. | m | 38.0 | 38.0 | 1200.0 | False | None | None | False | None | False | 45600.0 | 0 | 4080781 | 158827 | None | code193 | Supplying and drawing pvc insulated gas injected physical foam jelly filled co axial TV Cable Rg6: Single I/0, sl.no-8.10.1. | Each | 490.0 | 490.0 | 60.0 | False | None | None | False | None | False | 29400.0 | 0 | 4080782 | 158827 | None | code194 | Supplying and drawing pvc insulated gas injected physical foam jelly filled co axial TV Cable Rg6: Double I/O, sl.no-8.10.2. | Each | 550.0 | 550.0 | 4.0 | False | None | None | False | None | False | 2200.0 | 0 | 4080783 | 158827 | None | code195 | Supplying and drawing pvc insulated gas injected physical foam jelly filled co axial TV Cable Rg6: 42U with 800 mm depth, sl.no-8.4.1. | Each | 43168.0 | 43168.0 | 1.0 | False | None | None | False | None | False | 43168.0 | 0 | 4080784 | 158827 | None | code196 | Supplying and drawing pvc insulated gas injected physical foam jelly filled co axial TV Cable Rg6: 24 port 10 / 100 /1000 Switch, sl.no-8.4.1. | Each | 7415.0 | 7415.0 | 2.0 | False | None | None | False | None | False | 14830.0 | 0 | 4080785 | 158827 | None | code197 | Supplying and drawing pvc insulated gas injected physical foam jelly filled co axial TV Cable Rg6: 1 Mtr patch cable, sl.no-8.11.1... | Each | 224.0 | 224.0 | 6.0 | False | None | None | False | None | False | 1344.0 | 0 | 4080786 | 158827 | None | code198 | Supplying and drawing pvc insulated gas injected physical foam jelly filled co axial TV Cable Rg6: 2 Mtr patch cable, sl.no-8.11.2.. | Each | 257.0 | 257.0 | 6.0 | False | None | None | False | None | False | 1542.0 | 0 | 4080787 | 158827 | None | code199 | Supplying and drawing pvc insulated gas injected physical foam jelly filled co axial TV Cable Rg6: 24 port 10 / 100 patch panel, sl.no-8.11.2.. | Each | 4100.0 | 4100.0 | 3.0 | False | None | None | False | None | False | 12300.0 | 0 | 4080788 | 158827 | None | code200 | PLUMBING AND SANITARY: Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. Sl.No 14.1.1, Page No.131, Volume-II | Nos | 4884.0 | 4884.0 | 1.0 | False | None | None | False | None | False | 4884.0 | 0 | 4080789 | 158827 | None | code201 | Providing and fixing white vitreous china pedestal type water closet
(European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. Sl.No 14.3.1, Page No.131, Volume-II | Nos | 5977.0 | 5977.0 | 2.0 | False | None | None | False | None | False | 11954.0 | 0 | 4080790 | 158827 | None | code202 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with
a 15 mm CP Brass single hole basin mixer. Sl.No 14.7A, Page No.133, Volume-II | Nos | 4121.0 | 4121.0 | 5.0 | False | None | None | False | None | False | 20605.0 | 0 | 4080791 | 158827 | None | code203 | Providing and fixing 100 mm sand cast Iron grating for gully trap. Sl.No 14.29, Page No.136, Volume-II. | Nos | 47.0 | 47.0 | 4.0 | False | None | None | False | None | False | 188.0 | 0 | 4080792 | 158827 | None | code204 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. Sl.No 13.15, Page No.119, Volume-II | Nos | 725.0 | 725.0 | 11.0 | False | None | None | False | None | False | 7975.0 | 0 | 4080793 | 158827 | None | code205 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g. Sl.No 13.13, Page No.119, Volume-II | Nos | 846.0 | 846.0 | 11.0 | False | None | None | False | None | False | 9306.0 | 0 | 4080794 | 158827 | None | code206 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore, Sl.No 13.4.1, Page No.117, Volume-II | Nos | 549.0 | 549.0 | 1.0 | False | None | None | False | None | False | 549.0 | 0 | 4080795 | 158827 | None | code207 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) ; 32 mm nominal bore, Sl.No 13.4.2, Page No.117, Volume-II | Nos | 598.0 | 598.0 | 1.0 | False | None | None | False | None | False | 598.0 | 0 | 4080796 | 158827 | None | code208 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) ; 40 mm nominal bore, Sl.No 13.4.3, Page No.117, Volume-II | Nos | 702.0 | 702.0 | 1.0 | False | None | None | False | None | False | 702.0 | 0 | 4080797 | 158827 | None | code209 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore, Sl.No 13.4.4, Page No.117, Volume-II | Nos | 855.0 | 855.0 | 1.0 | False | None | None | False | None | False | 855.0 | 0 | 4080798 | 158827 | None | code210 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) ; 65 mm nominal bore, Sl.No 13.4.5, Page No.117, Volume-II | Nos | 1411.0 | 1411.0 | 1.0 | False | None | None | False | None | False | 1411.0 | 0 | 4080799 | 158827 | None | code211 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 80 mm nominal bore, Sl.No 13.4.6, Page No.117, Volume-II | Nos | 2077.0 | 2077.0 | 1.0 | False | None | None | False | None | False | 2077.0 | 0 | 4080800 | 158827 | None | code212 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Sl.No 14.31, Page No.136, Volume-II | Nos | 1220.0 | 1220.0 | 4.0 | False | None | None | False | None | False | 4880.0 | 0 | 4080801 | 158827 | None | code213 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Sl.No 14.40.2, Page No.137, Volume-II | Nos | 496.0 | 496.0 | 4.0 | False | None | None | False | None | False | 1984.0 | 0 | 4080802 | 158827 | None | code214 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 160mm dia., 6 kg/sqcm & class 3. Sl.No 10.1.9, PG.NO-113, VOLUME-5. | m | 618.0 | 618.0 | 30.0 | False | None | None | False | None | False | 18540.0 | 0 | 4080803 | 158827 | None | code215 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 110mm dia., 6 kg/sqcm & class 3. Sl.No 10.1.7, PG.NO-113, VOLUME-5. | m | 411.0 | 411.0 | 20.0 | False | None | None | False | None | False | 8220.0 | 0 | 4080804 | 158827 | None | code216 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 90mm dia., 6 kg/sqcm & class 3. Sl.No 10.1.6, PG.NO-113, VOLUME-5. | m | 294.0 | 294.0 | 20.0 | False | None | None | False | None | False | 5880.0 | 0 | 4080805 | 158827 | None | code217 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - 50 mm nominal dia Pipes. Sl.No 13.31.6, PG.NO-122, VOL-2. | m | 781.0 | 781.0 | 20.0 | False | None | None | False | None | False | 15620.0 | 0 | 4080806 | 158827 | None | code218 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 32 mm dia. Sl.No 13.32.4, page-122, VOL-2. | m | 557.0 | 557.0 | 20.0 | False | None | None | False | None | False | 11140.0 | 0 | 4080807 | 158827 | None | code219 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 25 mm dia. Sl.No 13.32.3, page-122, VOL-2. | m | 477.0 | 477.0 | 20.0 | False | None | None | False | None | False | 9540.0 | 0 | 4080808 | 158827 | None | code220 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 20 mm dia. Sl.No 13.32.2, page-122, VOL-2. | m | 379.0 | 379.0 | 15.0 | False | None | None | False | None | False | 5685.0 | 0 | 4080809 | 158827 | None | code221 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. Sl.No 16.10,page-191, VOL-5. | Nos | 4236.0 | 4236.0 | 2.0 | False | None | None | False | None | False | 8472.0 | 0 | 4080810 | 158827 | None | code222 | KSRB 11-18-9.1 : Providing and fixing sand cast iron soil waste single equal junction of required degree with access door 100x100x100mm, including cost of materials, labour, testing complete as per specifications. Specification No. KBS 11.1.10, Sl. No. 12.71, Page No. 87 | Nos | 933.0 | 933.0 | 1.0 | False | None | None | False | None | False | 933.0 | 0 | 4080811 | 158827 | None | code223 | Providing and placing on terrace (at all floor levels) polyethylene
water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Sl.No 13.34, page-123, VOL-2. | Ltr | 9.0 | 9.0 | 2000.0 | False | None | None | False | None | False | 18000.0 | 0 |
|