4095137 | 159482 | None | 1.14 | Road way by manual means for lowering & levelling the ground for all works other than foundation & depth in Ordinary rock and soft rock upto 300mm depth as per drawing and technical specifications, including setting out, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. | Cum | 603.75 | 603.75 | 12.66 | False | None | None | False | None | False | 7643.475 | 0 |
4095138 | 159482 | None | 1.23 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications [ PWD SR V-1 Page No 11 Item No 1.23 ] | Cum | 2816.1 | 2816.1 | 7.03 | False | None | None | False | None | False | 19797.183 | 0 |
4095139 | 159482 | None | 2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates [ PWD SR V-1 Page No 15 Item No 2.1.2 ] | Cum | 5947.2 | 5947.2 | 4.95 | False | None | None | False | None | False | 29438.64 | 0 |
4095140 | 159482 | None | 5.2 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) [ PWD SR V-2 Page No 9 Item No 5.2 | Cum | 6948.9 | 6948.9 | 5.83 | False | None | None | False | None | False | 40512.087 | 0 |
4095141 | 159482 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) [ PWD SR V-2 Page No 9 Item No 5.4 ] | Cum | 6708.45 | 6708.45 | 4.4 | False | None | None | False | None | False | 29517.18 | 0 |
4095142 | 159482 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. [ PWD SR Page v-1 No 7. Item No. 1.9 ] | Cum | 279.3 | 279.3 | 8.63 | False | None | None | False | None | False | 2410.359 | 0 |
4095143 | 159482 | None | 2.1.4 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates [ PWD SR V-1 Page No 15 Item No 2.1.4] | Cum | 9791.78 | 9791.78 | 1.47 | False | None | None | False | None | False | 14393.9166 | 0 |
4095144 | 159482 | None | 11.33 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications.[ PWD SR V-1 Page No 84 Item No 11.33] | Tonne | 93929.85 | 93929.85 | 0.18 | False | None | None | False | None | False | 16907.373 | 0 |
4095145 | 159482 | None | 6.2 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour,scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. PWD SR volume 2 Page No 13 Item No. 6.2 ] | Cum | 8376.9 | 8376.9 | 12.31 | False | None | None | False | None | False | 103119.639 | 0 |
4095146 | 159482 | None | 2.2.1.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates[ PWD SR V-1 Page No 15 Item No 2.2.1.1] | Cum | 10562.16 | 10562.16 | 0.75 | False | None | None | False | None | False | 7921.62 | 0 |
4095147 | 159482 | None | 2.2.1.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials , quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates[ PWD SR V-1 Page No 15 Item No 2.2.1.1] | Cum | 9902.03 | 9902.03 | 3.51 | False | None | None | False | None | False | 34756.1253 | 0 |
4095148 | 159482 | None | 11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. [ PWD S R 2021-22 V-2 Page No 75 Item No.11.5.2] | Sqm | 4454.1 | 4454.1 | 6.3 | False | None | None | False | None | False | 28060.83 | 0 |
4095149 | 159482 | None | 11.34a | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding [ PWD S R 2021-22 V-2 Page No 86 Item No.11.34a. ] | Sqm | 176.4 | 176.4 | 22.68 | False | None | None | False | None | False | 4000.752 | 0 |
4095150 | 159482 | None | 8.2.2 | Providing 15 mm thick cement plastering on the rough side or half brick wall of mix 1:6 ( 1 cement: 6 fine sand ) including rounding off corners wherever required smooth rendering providing and removing scaffolding, including cost of materials. labour, curing complete as per specifications and as per directions of Engineer-in-charges [ PWD SR Volume-2 Page No 41 Item No. 8.2.2 ] | Sqm | 292.95 | 292.95 | 123.12 | False | None | None | False | None | False | 36068.004 | 0 |
4095151 | 159482 | None | 2.2.1.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials , quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates[ PWD SR V-1 Page No 15 Item No 2.2.1.1] | Sqm | 6601.35 | 6601.35 | 3.27 | False | None | None | False | None | False | 21586.4145 | 0 |
4095152 | 159482 | None | 10.14 | Providing and fixing I st quality glazed wall tiles confirming to IS 15622 ( thickness to be specifed by the manufacturer ) of apprved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in charge, in skirting, raises of steps and dados over 12mmthcik bed of cement mortar 1:3 ( 1 cement : 3 Coarse sand ) and jointing with grey cement slurry @ 3.3 kg per m2, including pointing in white cement mixed with pigment of matching shade complete as per directions of Engineer-in-charges [ PWD SR Volume-2 Page No 71 Item No.10.14 ] | Sqm | 1012.2 | 1012.2 | 44.28 | False | None | None | False | None | False | 44820.216 | 0 |
4095153 | 159482 | None | 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300mm ( thickness to be specifed by the manufacture ) of Ist quality confirming to IS: 15622, of approved make in all colours, shades, except, white, Ivory, Grey, Fume Red Brown, laid on 20mm thick bed of cement mortar 1:4 ( i cment : 4 coarse sand ) jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete as per directions of Engineer-in-charges [ PWD SR Volume-2 Page No 60Item No. 9.11 ] | Sqm | 933.45 | 933.45 | 11.88 | False | None | None | False | None | False | 11089.386 | 0 |
4095154 | 159482 | None | 261 | Cudddapah slab 2.5cms thick.[PWD SR volume 2 PAGE NO:A 19 ITEM NO:261 ] | Sqm | 485.1 | 485.1 | 9.3 | False | None | None | False | None | False | 4511.43 | 0 |
4095155 | 159482 | None | 8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.[ PWD SR Volume-2 Page No 45 Item No 8.25] | Sqm | 143.85 | 143.85 | 92.69 | False | None | None | False | None | False | 13333.4565 | 0 |
4095156 | 159482 | None | 8.31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.[ PWD SR Volume-2 Page No 46 Item No 8.31] | Sqm | 186.9 | 186.9 | 44.09 | False | None | None | False | None | False | 8240.421 | 0 |
4095157 | 159482 | None | 1.1.1 | Supplying heavy gauge PVC conduit pipe …….dia .mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. (P, 2 I.No. 1.1.], 19/20mm dia 2mm thick (P, 2, I.No. 1.1.1] | Rmtr | 69.0 | 69.0 | 10.0 | False | None | None | False | None | False | 690.0 | 0 |
4095158 | 159482 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (P, 5, I.No. 2.3 | Rmtr | 26.0 | 26.0 | 30.0 | False | None | None | False | None | False | 780.0 | 0 |
4095159 | 159482 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (P, 5, I.No. 2.3.2.5 | Rmtr | 42.0 | 42.0 | 20.0 | False | None | None | False | None | False | 840.0 | 0 |
4095160 | 159482 | None | 3.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P, 9, I.No. 3.4] | Each | 177.0 | 177.0 | 2.0 | False | None | None | False | None | False | 354.0 | 0 |
4095161 | 159482 | None | 3.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (P, 9, I.No. 3.5] | Each | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 |
4095162 | 159482 | None | 3.6 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P, 10, I.No. 3.6] | Each | 102.0 | 102.0 | 5.0 | False | None | None | False | None | False | 510.0 | 0 |
4095163 | 159482 | None | 12.46 | Supplying & Fixing of 70-150 W lamp holder 2 Pin(P, 52, I.No.12.46] | Each | 63.0 | 63.0 | 4.0 | False | None | None | False | None | False | 252.0 | 0 |
4095164 | 159482 | None | 3.5 | Supplyingandfixingsurface/flushmountingunbreakablePVCmodularboxsuitableformountingmodularswitchplateswithduegroovecuttinginBrick/C.Cwall,includingnecessaryrawlplugs,Machine/NF screws etc., complete. (P, 9, I.No. 3.5] | Each | 137.0 | 137.0 | 3.0 | False | None | None | False | None | False | 411.0 | 0 |
4095165 | 159482 | None | 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. [p, 27 I.No 5.17], 6-32 Amps SP [p, 27 I.No. 5.18.1] | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 |
4095166 | 159482 | None | 2.1 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (P, 5, I.No. 2.1] | Each | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 |
4095167 | 159482 | None | 11.11.5 | Supplying fixing of retrofit type LED bulb.W with OPA Lacrylic diffuser comprising of LED source with CCT 6500 degree K,CRI70. efficacy80 lumenper W ,life25000 burning hour sand Compliance to IS10322 IEC60598 ,LM79 & LM80. The LED are drivenby HF electronic driver integrate dinthe system, with PF0.95, power loss should 5%of lamp Wage. ,short circuit & open circuit protecti on tobeintegrate dinthe circuit ,THD lessthan20, Life asper LM79. The operating input voltage should bebetween 130to275V. BISA pprovedand Tested by NABL/CPRI accredited laboratory with 2years Warranty againstany manufacturing defect working under standard electrical condition.12W, 6500K [p, 47 I.No. 11.11.5 | Each | 269.0 | 269.0 | 4.0 | False | None | None | False | None | False | 1076.0 | 0 |
4095168 | 159482 | None | 14.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. [p, 79 I.No 14.5] | Each | 175.0 | 175.0 | 4.0 | False | None | None | False | None | False | 700.0 | 0 |
4095169 | 159482 | None | 14.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors whereve required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests PWD SR volume 2 Page No 131 Item No. 14.1.1 ] | Nos | 5128.2 | 5128.2 | 2.0 | False | None | None | False | None | False | 10256.4 | 0 |
4095170 | 159482 | None | 14.4.1 | Providing and fixing white vitreous china flat back or wall corner type
lipped front urinal basin of 430x260x350 mm and 340x410x265 mm
sizes respectively with automatic flushing cistern with standard flush
pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern PWD SR volume 2 Page No 131 Item No. 14.4.1 ] | Nos | 4676.7 | 4676.7 | 2.0 | False | None | None | False | None | False | 9353.4 | 0 |
4095171 | 159482 | None | 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.[PWD SR volume 2 PAGE NO.123 ITEM NO:13.34 ] | Ltr | 9.45 | 9.45 | 500.0 | False | None | None | False | None | False | 4725.0 | 0 |
4095172 | 159482 | None | 13.50.3 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes [ PWDSR v2 Page No 125 Item No. 13.50.3] | Nos | 235.2 | 235.2 | 65.0 | False | None | None | False | None | False | 15288.0 | 0 |
4095173 | 159482 | None | 14.8 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. PWD SR volume 2 Page No 123 Item No. 14.8 ] | Nos | 1494.15 | 1494.15 | 2.0 | False | None | None | False | None | False | 2988.3 | 0 |
4095174 | 159482 | None | 11.20 | Providing and fixing perforated Reinforced concrete rings 1500mm inner dia and 300mm height including transporting and levelling chargesRWS&S circle2019-20(Sl No 11.20.1page no 116) | Nos | 1537.2 | 1537.2 | 12.0 | False | None | None | False | None | False | 18446.4 | 0 |