1727335835000 | 0 | None | None | Other Works | Construction of Toilet block at 400kV Receiving Station, Nelamangala. | 1499864.5 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4080504 | 158823 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m (Vol- 1 , P.No- 8 , SL.No- 1.14.1) | Cum | 123.97 | 123.97 | 40.0 | False | None | None | False | None | False | 4958.8 | 0 | 4080505 | 158823 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (Vol- 1 , P.No- 15 , SL.No- 2.1.2) | Cum | 6884.02 | 6884.02 | 2.0 | False | None | None | False | None | False | 13768.04 | 0 | 4080506 | 158823 | None | code03 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (Vol- 2 , P.No- 9 , SL.No- 5.4) | Cum | 7765.19 | 7765.19 | 5.0 | False | None | None | False | None | False | 38825.95 | 0 | 4080507 | 158823 | None | code04 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures (Vol- 1 , P.No- 18 , SL.No- 2.11 h) | Tonne | 108726.03 | 108726.03 | 1.25 | False | None | None | False | None | False | 135907.5375 | 0 | 4080508 | 158823 | None | code05 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol- 1 , P.No- 16 , SL.No- 2.4.2) Footing (ERS) Percentage Additionalities for Formwork,
Centering 10% (Vol- 1 , P.No- 112 , SL.No- 11) | Cum | 8453.47 | 8453.47 | 6.0 | False | None | None | False | None | False | 50720.82 | 0 | 4080509 | 158823 | None | code06 | Columns Percentage Additionalities for Formwork,
Centering 70% (Vol- 1 , P.No- 112 , SL.No- 11) | Cum | 13064.45 | 13064.45 | 3.25 | False | None | None | False | None | False | 42459.4625 | 0 | 4080510 | 158823 | None | code07 | Plinth Beams of Building Percentage Additionalities for Formwork, Centering 50% (Vol- 1 , P.No- 112 , SL.No- 11) | Cum | 11527.46 | 11527.46 | 3.5 | False | None | None | False | None | False | 40346.11 | 0 | 4080511 | 158823 | None | code08 | RCC Beams Percentage Additionalities for Formwork,
Centering 60% (Vol- 1 , P.No- 112 , SL.No- 11) | Cum | 12295.95 | 12295.95 | 2.5 | False | None | None | False | None | False | 30739.875 | 0 | 4080512 | 158823 | None | code09 | RCC Roof Slabs Percentage Additionalities for Formwork, Centering 50% (Vol- 1 , P.No- 112 , SL.No- 11) | Cum | 11527.46 | 11527.46 | 5.5 | False | None | None | False | None | False | 63401.03 | 0 | 4080513 | 158823 | None | code10 | Chejjas Percentage Additionalities for Formwork, Centering 45% (Vol- 1 , P.No- 112 , SL.No- 11) | Cum | 11143.21 | 11143.21 | 0.3 | False | None | None | False | None | False | 3342.963 | 0 | 4080514 | 158823 | None | code11 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (Vol- 1 , P.No- 15 , SL.No- 2.1.4) | Cum | 7556.14 | 7556.14 | 3.0 | False | None | None | False | None | False | 22668.42 | 0 | 4080515 | 158823 | None | code12 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Vol- 2 , P.No- 17 , SL.No- 6.32) | Sqm | 1592.17 | 1592.17 | 96.0 | False | None | None | False | None | False | 152848.32 | 0 | 4080516 | 158823 | None | code13 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Vol- 2, P.No- 17 , SL.No- 6.33) | Sqm | 1496.15 | 1496.15 | 30.0 | False | None | None | False | None | False | 44884.5 | 0 | 4080517 | 158823 | None | code14 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Vol- 2 , P.No- 42 , SL.No- 8.8) | Sqm | 450.91 | 450.91 | 100.0 | False | None | None | False | None | False | 45091.0 | 0 | 4080518 | 158823 | None | code15 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Vol- 2 , P.No- 41 , SL.No- 8.1.2) | Sqm | 292.91 | 292.91 | 115.0 | False | None | None | False | None | False | 33684.65 | 0 | 4080519 | 158823 | None | code16 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Vol- 2, P.No- 50, SL.No- 8.51) | Sqm | 121.53 | 121.53 | 50.0 | False | None | None | False | None | False | 6076.5 | 0 | 4080520 | 158823 | None | code17 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direc tion of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile (Vol- 2, P.No- 59, SL.No- 9.7.1) | Sqm | 1514.38 | 1514.38 | 40.0 | False | None | None | False | None | False | 60575.2 | 0 | 4080521 | 158823 | None | code18 | In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile (Vol- 2, P.No- 60, SL.No- 9.7.2) | Sqm | 1531.4 | 1531.4 | 140.0 | False | None | None | False | None | False | 214396.0 | 0 | 4080522 | 158823 | None | code19 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as perspecifications and as per directions of Engineer-in-charge.(Vol- 2 , P.No- 51, SL.No- 8.39 ) | Sqm | 154.35 | 154.35 | 50.0 | False | None | None | False | None | False | 7717.5 | 0 | 4080523 | 158823 | None | code20 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol- 2, P.No- 46 , SL.No- 8.32) | Sqm | 189.6 | 189.6 | 80.0 | False | None | None | False | None | False | 15168.0 | 0 | 4080524 | 158823 | None | code21 | Providing & fixing of louvered ventilator made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2 (Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Vol- 2, P.No- 109, SL.No- 12.85) | Sqm | 6950.87 | 6950.87 | 1.0 | False | None | None | False | None | False | 6950.87 | 0 | 4080525 | 158823 | None | code22 | Providing Sal wood wrought and putup for purlins, common rafters and similar work including cost of materials, labour, usage charges complete as per specifications. (Vol- 2, P.No- 99, SL.No- 12.4) | Cum | 117908.38 | 117908.38 | 0.5 | False | None | None | False | None | False | 58954.19 | 0 | 4080526 | 158823 | None | code23 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) (Vol- 2, P.No- 100, SL.No- 12.15) | Sqm | 9047.43 | 9047.43 | 3.0 | False | None | None | False | None | False | 27142.29 | 0 | 4080527 | 158823 | None | code24 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness(Vol-2, Pg 112, Item No:12.94.1) | Sqm | 4235.66 | 4235.66 | 8.5 | False | None | None | False | None | False | 36003.11 | 0 | 4080528 | 158823 | None | code25 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (Vol- 2, P.No- 60, SL.No- 9.7.2) | Each | 5880.1 | 5880.1 | 5.0 | False | None | None | False | None | False | 29400.5 | 0 | 4080529 | 158823 | None | code26 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern (Vol- 2, P.No- 132, SL.No- 14.5.1) | Each | 10503.48 | 10503.48 | 2.0 | False | None | None | False | None | False | 21006.96 | 0 | 4080530 | 158823 | None | code27 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. (Vol- 2, P.No- 70, SL.No- 10.8) | Sqm | 3389.75 | 3389.75 | 2.0 | False | None | None | False | None | False | 6779.5 | 0 | 4080531 | 158823 | None | code28 | Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. (Vol- 2, P.No- 63, SL.No- 9.29) | Sqm | 5233.51 | 5233.51 | 6.0 | False | None | None | False | None | False | 31401.06 | 0 | 4080532 | 158823 | None | code29 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall (Vol- 2 , P.No- 15, SL.No- 2.1.4 ) i)- 50mm nominal OD pipes (Vol- 2, P.No-119, SL.No- 13.33.6) | Mtr | 876.3 | 876.3 | 30.0 | False | None | None | False | None | False | 26289.0 | 0 | 4080533 | 158823 | None | code30 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall (Vol- 2 , P.No- 15, SL.No- 2.1.4 ) ii)- 40mm nominal OD pipes (Vol- 2, P.No-119, SL.No- 13.33.5) | Mtr | 579.74 | 579.74 | 25.0 | False | None | None | False | None | False | 14493.5 | 0 | 4080534 | 158823 | None | code31 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall (Vol- 2 , P.No- 15, SL.No- 2.1.4 ) iii)- 25mm nominal OD pipes (Vol- 2, P.No-119, SL.No- 13.33.3) | Mtr | 359.75 | 359.75 | 75.0 | False | None | None | False | None | False | 26981.25 | 0 | 4080535 | 158823 | None | code32 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall (Vol- 2 , P.No- 15, SL.No- 2.1.4 ) iv)- 20mm nominal OD pipes (Vol- 2, P.No-119, SL.No- 13.33.2) | Mtr | 263.74 | 263.74 | 35.0 | False | None | None | False | None | False | 9230.9 | 0 | 4080536 | 158823 | None | code33 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete (Vol- 5, P.No- 113, SL.No- 10.1) PVC pipes 160mm dia., 6 kg/sqcm & class 2 (Vol- 5, P.No- 113, SL.No- 10.1.9) | Mtr | 751.11 | 751.11 | 15.0 | False | None | None | False | None | False | 11266.65 | 0 | 4080537 | 158823 | None | code34 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete (Vol- 5, P.No- 113, SL.No- 10.1) PVC pipes 110mm dia., 6 kg/sqcm & class 3 (Vol- 5, P.No- 113, SL.No- 10.7) | Mtr | 499.52 | 499.52 | 70.0 | False | None | None | False | None | False | 34966.4 | 0 | 4080538 | 158823 | None | code35 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (Vol- 5, P.No- 117, SL.No- 10.9) 160 mm dia PVC Elbows (Vol- 5, P.No- 117, SL.No- 10.9.10) | Each | 572.45 | 572.45 | 5.0 | False | None | None | False | None | False | 2862.25 | 0 | 4080539 | 158823 | None | code36 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (Vol- 5, P.No- 117, SL.No- 10.9) 110 mm dia PVC Elbows (Vol- 5, P.No- 117, SL.No- 10.9.8) | Each | 367.05 | 367.05 | 8.0 | False | None | None | False | None | False | 2936.4 | 0 | 4080540 | 158823 | None | code37 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover (Vol- 5, P.No- 191, SL.No- 16.9) | Each | 6628.79 | 6628.79 | 4.0 | False | None | None | False | None | False | 26515.16 | 0 | 4080541 | 158823 | None | code38 | Providing and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete. Heavy Duty (Vol- 5, P.No- 196, SL.No- 16.23.2) | Set | 3116.28 | 3116.28 | 4.0 | False | None | None | False | None | False | 12465.12 | 0 | 4080542 | 158823 | None | code39 | Providing and fixing PTMT grating of approved quality and colour. Circular type. 100 mm nominal dia(Vol- 2, P.No- 120, SL.No- 13.22.1.1) | No | 49.83 | 49.83 | 11.0 | False | None | None | False | None | False | 548.13 | 0 | 4080543 | 158823 | None | code40 | White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap ( Volume-2, Page -132 Item No: 14.7.2) | Each | 3112.63 | 3112.63 | 4.0 | False | None | None | False | None | False | 12450.52 | 0 | 4080544 | 158823 | None | code41 | Providing and fixing PTMT, push cock of approved quality and colour 15 mm nominal bore, 80 mm long, weighing not less than 46 g ( Volume-2, Page -120 Item No: 13.21.2) | No | 162.86 | 162.86 | 2.0 | False | None | None | False | None | False | 325.72 | 0 | 4080545 | 158823 | None | code42 | Providing and fixing Angle cock medium with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Premium ( Volume-2, Page -139 Item No: 14.53 b) | No | 1765.97 | 1765.97 | 4.0 | False | None | None | False | None | False | 7063.88 | 0 | 4080546 | 158823 | None | code43 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g. (Vol- 2, P.No- 119, SL.No- 13.14) | No | 1028.22 | 1028.22 | 10.0 | False | None | None | False | None | False | 10282.2 | 0 | 4080547 | 158823 | None | code44 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. (Vol- 2, P.No- 137, SL.No- 14.40.2) | Each | 602.83 | 602.83 | 4.0 | False | None | None | False | None | False | 2411.32 | 0 | 4080548 | 158823 | None | code45 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g (Vol- 2, P.No- 121, SL.No- 13.26) | Each | 121.53 | 121.53 | 4.0 | False | None | None | False | None | False | 486.12 | 0 | 4080549 | 158823 | None | code46 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (Vol- 2, P.No- 123, SL.No- 13.34) | l | 10.93 | 10.93 | 2000.0 | False | None | None | False | None | False | 21860.0 | 0 | 4080550 | 158823 | None | code47 | Wiringfor lighting/powercircuitusingoneof FRLSPVC insulated 1100Vgrade, multistrand copperwire withlowconductor resistance singlecore inopenorconcealed system of wiring with specifiedIS 694:2010 (Vol- 6 , P.No- 5 PWD Electrical SR Part-1 , SL.No- 2.3.2 ) a) 1.5 mm2 (Vol- 6 , P.No- 5 PWD Electrical SR Part-1 , SL.No- 2.3.2 ) | m | 31.6 | 31.6 | 30.0 | False | None | None | False | None | False | 948.0 | 0 | 4080551 | 158823 | None | code48 | Wiringfor lighting/powercircuitusingoneof FRLSPVC insulated 1100Vgrade, multistrand copperwire withlowconductor resistance singlecore inopenorconcealed system of wiring with specifiedIS 694:2010 (Vol- 6 , P.No- 5 PWD Electrical SR Part-1 , SL.No- 2.3.2 ) b) 2.5 mm2 (Vol- 6 , P.No- 5 PWD Electrical SR Part-1 , SL.No- 2.3.3 ) | m | 51.04 | 51.04 | 50.0 | False | None | None | False | None | False | 2552.0 | 0 | 4080552 | 158823 | None | code49 | Supplying and fixing PVC/metal conduit Deep junction box. 19/20 mm deep Junction box (Vol- 6 , P.No- 2 PWD Electrical SR Part-1 , SL.No- 1.5.1 ) | Each | 59.55 | 59.55 | 4.0 | False | None | None | False | None | False | 238.2 | 0 | 4080553 | 158823 | None | code50 | Supplying heavygaugePVCconduit pipe ....... dia .......mmthick confirming to IS 2509 with suitable size bends, junction boxes, adhesive pasteetc , andfixingusinginvertedwoodplugs incaseof RCCceilingandRCCwall/ stonestructureor rawl plugs incaseof brickwalls andcement plastering thedamagedportionusingheavy gauge saddles at an interval of 700mm using NF screws. 19/20 mm dia 2 mm thick (Vol- 6 , P.No- 2 PWD Electrical SR Part-1 , SL.No- 1.1.1 ) | m | 83.86 | 83.86 | 40.0 | False | None | None | False | None | False | 3354.4 | 0 | 4080554 | 158823 | None | code51 | Supplyingof 1440rpmheavydutyexhaust fanwithbracket blades suitable to operate on 230V 50Hz, AC Supply complete. 15" Sweep (450 mm) (Vol- 6, P.No- 30, SL.No- 6.2.2) | Each | 5403.66 | 5403.66 | 2.0 | False | None | None | False | None | False | 10807.32 | 0 | 4080555 | 158823 | None | code52 | Fixingoneexhaust faninthenitchalready left inthewallwithbolts andnuts and5A. ceiling rosewithsufficient lengthof 23/0.0076 inch PVC insulated twin core wire. (Vol- 6, P.No- 57 , SL.No- 13.14) | Each | 597.97 | 597.97 | 2.0 | False | None | None | False | None | False | 1195.94 | 0 | 4080556 | 158823 | None | code53 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting a) 1 x 4' - 20/22 W (Vol- 6 , P.No- 34 PWD Electrical SR Part-1 , SL.No- 11.3.2) | Each | 838.62 | 838.62 | 4.0 | False | None | None | False | None | False | 3354.48 | 0 | 4080557 | 158823 | None | code54 | Fixing all types and all capacities of fluorescent /false ceiling /spot light / CFL / LED fittings indoor on the wall/ ceiling /rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders (Vol- 6 , P.No- 45 PWD Electrical SR Part-1 , SL.No- 13.7.1 ) | Each | 148.27 | 148.27 | 4.0 | False | None | None | False | None | False | 593.08 | 0 | 4080558 | 158823 | None | code55 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m (Vol- 1, P.No- 7 , SL.No- 1.9) | Cum | 247.94 | 247.94 | 20.0 | False | None | None | False | None | False | 4958.8 | 0 | 4080559 | 158823 | None | code56 | Disposal off the excess excavated earth of all types by vehicle including loading, unloading with all lead and lifts, labour, HOM of machineries etc. for Distance of 4 to 5 km: (Vol-5 , P.No-63 , SL.No- 4.5 ) | Cum | 160.43 | 160.43 | 20.0 | False | None | None | False | None | False | 3208.6 | 0 |
|