tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1727517857000 | 0 | None | None | Buildings | CONSTRUCTION OF OFFICE/GODOWN BUILDING OF PRIMERY AGREECULTURE COLLABRATIVE ASSOCIATION NI ANKALI IN CHIKKODI TALUKA | 1638658.57 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4101045 | 159782 | None | code01 | Earth work in surface excavation by mechanical means for lowering & levelingthe ground for all works other than foundation in all kinds of soils & upto depthnot exceeding 300mm as per drawing and technical specifications, includingsetting out, shoring, strutting, barricading, caution lights, removal of stumpsand other deleterious matter including dressing of excavated surfaces, disposingoff or levelling the excavated earth or sorting & stacking the selected earth forreuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth Complete as per direction of Engineer in charge. | Sqm | 99.75 | 99.75 | 48.75 | False | None | None | False | None | False | 4862.8125 | 0 | 4101046 | 159782 | None | code02 | Earth work excavation for Foundation by mechanical means for all works &depth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the excavated earth or sorting& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenacesrequired to complete the work In all kinds of soils Depth upto 3 m Complete as per direction of Engineer in charge. | Cum | 107.1 | 107.1 | 35.01 | False | None | None | False | None | False | 3749.571 | 0 | 4101047 | 159782 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates Complete as per direction of Engineer in charge. | Cum | 6288.45 | 6288.45 | 3.69 | False | None | None | False | None | False | 23204.3805 | 0 | 4101048 | 159782 | None | code04 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Complete as per direction of Engineer in charge. | Cum | 6652.8 | 6652.8 | 5.18 | False | None | None | False | None | False | 34461.504 | 0 | 4101049 | 159782 | None | code05 | Formwork & Centring Charges @ 8%. Complete as per direction of Engineer in charge. | Cum | 532.22 | 532.22 | 5.18 | False | None | None | False | None | False | 2756.8996 | 0 | 4101050 | 159782 | None | code06 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Complete as per direction of Engineer in charge. | Cum | 6652.8 | 6652.8 | 3.18 | False | None | None | False | None | False | 21155.904 | 0 | 4101051 | 159782 | None | code07 | Formwork & Centring Charges @70% Complete as per direction of Engineer in charge. | Cum | 4656.96 | 4656.96 | 0.99 | False | None | None | False | None | False | 4610.3904 | 0 | 4101052 | 159782 | None | code08 | Formwork & Centring Charges @50% Complete as per direction of Engineer in charge. | Cum | 3326.4 | 3326.4 | 2.19 | False | None | None | False | None | False | 7284.816 | 0 | 4101053 | 159782 | None | code09 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Complete as per direction of Engineer in charge. | Cum | 7185.15 | 7185.15 | 6.74 | False | None | None | False | None | False | 48427.911 | 0 | 4101054 | 159782 | None | code10 | Formwork & Centring Charges @70% Complete as per direction of Engineer in charge. | Cum | 5029.6 | 5029.6 | 2.79 | False | None | None | False | None | False | 14032.584 | 0 | 4101055 | 159782 | None | code11 | Formwork & Centring Charges @60% Complete as per direction of Engineer in charge. | Cum | 4311.09 | 4311.09 | 3.95 | False | None | None | False | None | False | 17028.8055 | 0 | 4101056 | 159782 | None | code12 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Complete as per direction of Engineer in charge. | Cum | 7185.15 | 7185.15 | 0.7 | False | None | None | False | None | False | 5029.605 | 0 | 4101057 | 159782 | None | code13 | Formwork & Centring Charges @45% Complete as per direction of Engineer in charge. | Cum | 3233.31 | 3233.31 | 0.7 | False | None | None | False | None | False | 2263.317 | 0 | 4101058 | 159782 | None | code14 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Complete as per direction of Engineer in charge. | Cum | 7185.15 | 7185.15 | 7.57 | False | None | None | False | None | False | 54391.5855 | 0 | 4101059 | 159782 | None | code15 | Formwork & Centring Charges @50% Complete as per direction of Engineer in charge. | Cum | 3592.57 | 3592.57 | 7.57 | False | None | None | False | None | False | 27195.7549 | 0 | 4101060 | 159782 | None | code16 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Complete as per direction of Engineer in charge. | Cum | 6948.9 | 6948.9 | 8.28 | False | None | None | False | None | False | 57536.892 | 0 | 4101061 | 159782 | None | code17 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (1 cement : 6 coarse sand) Complete as per direction of Engineer in charge. | Cum | 6515.25 | 6515.25 | 5.24 | False | None | None | False | None | False | 34139.91 | 0 | 4101062 | 159782 | None | code18 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Complete as per direction of Engineer in charge. | Cum | 8367.45 | 8367.45 | 19.91 | False | None | None | False | None | False | 166595.9295 | 0 | 4101063 | 159782 | None | code19 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Complete as per direction of Engineer in charge. | Tonne | 93929.85 | 93929.85 | 2.1537 | False | None | None | False | None | False | 202296.717945 | 0 | 4101064 | 159782 | None | code20 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Complete as per direction of Engineer in charge. | Cum | 279.3 | 279.3 | 34.43 | False | None | None | False | None | False | 9616.299 | 0 | 4101065 | 159782 | None | code21 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork shall be paid separately)Complete as per direction of Engineer in charge. | Cum | 6527.85 | 6527.85 | 4.25 | False | None | None | False | None | False | 27743.3625 | 0 | 4101066 | 159782 | None | code22 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 4 fne sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge. Complete as per direction of Engineer in charge. | Sqm | 292.95 | 292.95 | 117.45 | False | None | None | False | None | False | 34406.9775 | 0 | 4101067 | 159782 | None | code23 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) fnished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fne sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 135.49 | False | None | None | False | None | False | 52780.1295 | 0 | 4101068 | 159782 | None | code24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 117.45 | False | None | None | False | None | False | 12332.25 | 0 | 4101069 | 159782 | None | code25 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.. | Sqm | 2994.6 | 2994.6 | 57.7 | False | None | None | False | None | False | 172788.42 | 0 | 4101070 | 159782 | None | code26 | Providing and fxing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 176.4 | 176.4 | 189.0 | False | None | None | False | None | False | 33339.6 | 0 | 4101071 | 159782 | None | code27 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wallthickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of Complete as per direction of Engineer in charge. | Sqm | 7070.7 | 7070.7 | 9.0 | False | None | None | False | None | False | 63636.3 | 0 | 4101072 | 159782 | None | code28 | Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challenged Complete as per direction of Engineer in charge. | Kg | 593.25 | 593.25 | 121.77 | False | None | None | False | None | False | 72240.0525 | 0 | 4101073 | 159782 | None | code29 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. --do-- sal wood frames. Complete as per direction of Engineer in charge. | Cum | 103755.75 | 103755.75 | 0.14 | False | None | None | False | None | False | 14525.805 | 0 | 4101074 | 159782 | None | code30 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifcations Complete as per direction of Engineer in charge. | Nos | 1066.8 | 1066.8 | 1.0 | False | None | None | False | None | False | 1066.8 | 0 | 4101075 | 159782 | None | code31 | Providing and fxing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifcations. (excluding cost of fxtures) Complete as per direction of Engineer in charge. | Sqm | 7241.85 | 7241.85 | 3.22 | False | None | None | False | None | False | 23318.757 | 0 | 4101076 | 159782 | None | code32 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 117.45 | False | None | None | False | None | False | 16895.1825 | 0 | 4101077 | 159782 | None | code33 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge | Sqm | 297.15 | 297.15 | 135.49 | False | None | None | False | None | False | 40260.8535 | 0 | 4101078 | 159782 | None | code34 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 7241.85 | 7241.85 | 8.1 | False | None | None | False | None | False | 58658.985 | 0 | 4101079 | 159782 | None | code35 | Providing and fxing false ceiling at all height including providing and fxing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/m2 (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fxed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fxed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fxed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fxed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fxing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fxed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fxing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and fnishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , fnishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specifcation and also including the cost of making openings for light fttings, grills, diffusers, cutouts made with frame of perimeter channels suitably fxed, all complete as per drawings, specifcation and direction of the Engineer in Charge but excluding the cost of painting board Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer- in-charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60 Complete as per direction of Engineer in charge. | Sqm | 1387.05 | 1387.05 | 43.99 | False | None | None | False | None | False | 61016.3295 | 0 | 4101080 | 159782 | None | code36 | Providing and supplying cupboard shutter with 19mm thick one side Architect recommended decorative laminate (1mm thick) and other side balancing lamination(preferably white) on factory pressed BWP grade marine ply as per IS 710 of approved brand complete as per direction of engineer in-charge.(Payment for providing and fixing auto closing hinges shall be paid separately) Complete as per direction of Engineer in charge. | Sqm | 3108.0 | 3108.0 | 40.9 | False | None | None | False | None | False | 127117.2 | 0 | 4101081 | 159782 | None | code37 | Labour & installation charges for BWP ply:BWR ply:HDHMR: MDF & Particle board work of any thickness applicable for all types of work Complete as per direction of Engineer in charge. | Sqm | 2100.0 | 2100.0 | 40.9 | False | None | None | False | None | False | 85890.0 | 0 |
| 1727517857000 | 0 | None | None | Buildings | ELECTRIFICATION | 54456.15 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4101082 | 159783 | None | code01 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required. 25mm complete as per direction of the Engineer-in-charge of the work | Mtr | 36.75 | 36.75 | 80.0 | False | None | None | False | None | False | 2940.0 | 0 | 4101083 | 159783 | None | code02 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPERconductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A Short point upto 3Mtr from tapping point to out let via switch box complete as per direction of the Engineer-in-charge of the work | Point | 299.25 | 299.25 | 6.0 | False | None | None | False | None | False | 1795.5 | 0 | 4101084 | 159783 | None | code03 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box complete as per direction of the Engineer-in-charge of the work | Point | 413.7 | 413.7 | 3.0 | False | None | None | False | None | False | 1241.1 | 0 | 4101085 | 159783 | None | code04 | Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box complete as per direction of the Engineer-in-charge of the work | Point | 598.5 | 598.5 | 1.0 | False | None | None | False | None | False | 598.5 | 0 | 4101086 | 159783 | None | code05 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS694: 1990 & confirming to GTP of GROUP A. 1.5 sqmm complete as per direction of the Engineer-in-charge of the work | Mtr | 27.3 | 27.3 | 50.0 | False | None | None | False | None | False | 1365.0 | 0 | 4101087 | 159783 | None | code06 | 2.5 sqmm complete as per direction of the Engineer-in-charge of the work | Mtr | 44.1 | 44.1 | 80.0 | False | None | None | False | None | False | 3528.0 | 0 | 4101088 | 159783 | None | code07 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way complete as per direction of the Engineer-in-charge of the work | Each | 274.05 | 274.05 | 4.0 | False | None | None | False | None | False | 1096.2 | 0 | 4101089 | 159783 | None | code08 | 10-12Way complete as per direction of the Engineer-in-charge of the work | Each | 334.95 | 334.95 | 8.0 | False | None | None | False | None | False | 2679.6 | 0 | 4101090 | 159783 | None | code09 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module complete as per direction of the Engineer-in-charge of the work | Each | 298.2 | 298.2 | 4.0 | False | None | None | False | None | False | 1192.8 | 0 | 4101091 | 159783 | None | code10 | 10-12 Module complete as per direction of the Engineer-in-charge of the work | Each | 361.2 | 361.2 | 8.0 | False | None | None | False | None | False | 2889.6 | 0 | 4101092 | 159783 | None | code11 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A. 6 Amps one way Switch complete as per direction of the Engineer-in-charge of the work | Each | 107.1 | 107.1 | 15.0 | False | None | None | False | None | False | 1606.5 | 0 | 4101093 | 159783 | None | code12 | 6Amps 3 way Socket complete as per direction of the Engineer-in-charge of the work | Each | 179.55 | 179.55 | 4.0 | False | None | None | False | None | False | 718.2 | 0 | 4101094 | 159783 | None | code13 | Stepped fan Regulator complete as per direction of the Engineer-in-charge of the work | Each | 374.85 | 374.85 | 3.0 | False | None | None | False | None | False | 1124.55 | 0 | 4101095 | 159783 | None | code14 | 32 Amps Dp switch complete as per direction of the Engineer-in-charge of the work | Each | 342.3 | 342.3 | 2.0 | False | None | None | False | None | False | 684.6 | 0 | 4101096 | 159783 | None | code15 | Supplying & Fixing of 70-150 W lamp holder 2 Pin complete as per direction of the Engineer-in-charge of the work | Each | 66.15 | 66.15 | 30.0 | False | None | None | False | None | False | 1984.5 | 0 | 4101097 | 159783 | None | code16 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 16Amps complete as per direction of the Engineer-in-charge of the work | Each | 164.85 | 164.85 | 2.0 | False | None | None | False | None | False | 329.7 | 0 | 4101098 | 159783 | None | code17 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT. complete as per direction of the Engineer-in-charge of the work | Each | 1788.15 | 1788.15 | 1.0 | False | None | None | False | None | False | 1788.15 | 0 | 4101099 | 159783 | None | code18 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5-32 Amps SP complete as per direction of the Engineer-in-charge of the work | Each | 435.75 | 435.75 | 2.0 | False | None | None | False | None | False | 871.5 | 0 | 4101100 | 159783 | None | code19 | Supplying and fixing of 5'-80 W of T8 Fluorescent Tube with
54W power consumption with low 3mg Mercury content less
phosphor coating Operating voltage range from 180V to 265V,
50Hz AC power Supply. complete as per direction of the Engineer-in-charge of the work | Each | 546.0 | 546.0 | 10.0 | False | None | None | False | None | False | 5460.0 | 0 | 4101101 | 159783 | None | code20 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / Watt, Three Blades of blade leaf 1.05mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty 48" Sweep 5 Star (1200 mm) complete as per direction of the Engineer-in-charge of the work | Each | 2810.85 | 2810.85 | 3.0 | False | None | None | False | None | False | 8432.55 | 0 | 4101102 | 159783 | None | code21 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. (on wall/ceiling/rafter/girders complete as per direction of the Engineer-in-charge of the work | Each | 128.1 | 128.1 | 35.0 | False | None | None | False | None | False | 4483.5 | 0 | 4101103 | 159783 | None | code22 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 10sqmm complete as per direction of the Engineer-in-charge of the work | Mtr | 175.35 | 175.35 | 25.0 | False | None | None | False | None | False | 4383.75 | 0 | 4101104 | 159783 | None | code23 | Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts, 50Hz AC supply & completely wired on existing box complete as per direction of the Engineer-in-charge of the work | Each | 678.3 | 678.3 | 1.0 | False | None | None | False | None | False | 678.3 | 0 | 4101105 | 159783 | None | code24 | LT AC Single Phase 2 Wire, 5-30 Amps Smart Energy
Meter, Class 1.0 Accuracy with RF Communication
Module complete as per direction of the Engineer-in-charge of the work | Each | 2584.05 | 2584.05 | 1.0 | False | None | None | False | None | False | 2584.05 | 0 |
|
|
---|