tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1727506891000 | 0 | None | None | Buildings | Construction of two classroom to Govt Higher primary school in Hirehonalli village in kalghatagi tq dharwad Dist | 2265280.16 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4099414 | 159699 | None | vol 1 pg no 8 item no 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth | Cum | 95.0 | 95.0 | 16.2 | False | None | None | False | None | False | 1539.0 | 0 | 4099415 | 159699 | None | vol 1 pg no 8 item no 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3m | Cum | 102.0 | 102.0 | 111.31 | False | None | None | False | None | False | 11353.62 | 0 | 4099416 | 159699 | None | vol 1 pg no 15 item no 2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5989.0 | 5989.0 | 23.02 | False | None | None | False | None | False | 137866.78 | 0 | 4099417 | 159699 | None | vol 1 pg no 15 item no 2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6336.0 | 6336.0 | 16.02 | False | None | None | False | None | False | 101502.72 | 0 | 4099418 | 159699 | None | vol 1 pg no 111 item no 1b | Additional for formwork, Centering & Scaffolding for Sl No 1 b: Foundation upto plinth all other types As per Appendix-I in Volume-1 of page No.-115 (@3% of Finished Rate) | Cum | 190.08 | 190.08 | 16.02 | False | None | None | False | None | False | 3045.0816 | 0 | 4099419 | 159699 | None | vol 1 pg no 16 item no 2.3.2 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6480.0 | 6480.0 | 1.57 | False | None | None | False | None | False | 10173.6 | 0 | 4099420 | 159699 | None | vol 1 pg no 111 item no 9 | Additional for formwork, Centering & Scaffolding for Sl No 9: Columns As per Appendix-I in Volume-1 of page No.-115 (@70% of Finished Rate) | Cum | 4536.0 | 4536.0 | 1.57 | False | None | None | False | None | False | 7121.52 | 0 | 4099421 | 159699 | None | vol 1 pg no 16 item no 2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6630.0 | 6630.0 | 38.97 | False | None | None | False | None | False | 258371.1 | 0 | 4099422 | 159699 | None | vol 1 pg no 111 item no 9 | Additional for formwork, Centering & Scaffolding for Sl No 9 Columns As per Appendix-I in (@70% of Finished Rate)
| Cum | 4641.0 | 4641.0 | 5.8 | False | None | None | False | None | False | 26917.8 | 0 | 4099423 | 159699 | None | vol 1 pg no 111 item no 2 | Additional for formwork, Centering & Scaffolding for Sl No 1a : Plinth beams of building As per (@50% of Finished Rate)
| Cum | 3315.0 | 3315.0 | 5.88 | False | None | None | False | None | False | 19492.2 | 0 | 4099424 | 159699 | None | vol 1 pg no 112 item no 14 | Additional for formwork, Centering & Scaffolding for Sl No 12 : beam & lintels of building As per (@60% of Finished Rate)
| Cum | 3978.0 | 3978.0 | 9.68 | False | None | None | False | None | False | 38507.04 | 0 | 4099425 | 159699 | None | vol 1 pg no 112 item no 19 | Additional for formwork, Centering & Scaffolding for Sl No 20 : Chejjas, Canopy & Other Architectural projections of minor sections As per (@45% of Finished Rate)
| Cum | 2983.5 | 2983.5 | 0.27 | False | None | None | False | None | False | 805.545 | 0 | 4099426 | 159699 | None | vol 1 pg no 112 item no 15 | Additional for formwork, Centering & Scaffolding for Sl No 15 : Roof slab (@50% of Finished Rate)
| Cum | 3315.0 | 3315.0 | 17.34 | False | None | None | False | None | False | 57482.1 | 0 | 4099427 | 159699 | None | vol 1 pg no 18 item no 2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 89457.0 | 89457.0 | 5.13 | False | None | None | False | None | False | 458914.41 | 0 | 4099428 | 159699 | None | vol 2 pg no 9 item no 5.1.1 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 5611.0 | 5611.0 | 41.58 | False | None | None | False | None | False | 233305.38 | 0 | 4099429 | 159699 | None | vol 1 pg no 7 item no 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
| Cum | 266.0 | 266.0 | 56.3 | False | None | None | False | None | False | 14975.8 | 0 | 4099430 | 159699 | None | vol 1 pg no 7 item no 1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water,all materials,usage& all other appurtenaces required to complete the work.Deduct 5% percum if rollers are not used and tamping is done manually | Cum | 474.0 | 474.0 | 62.02 | False | None | None | False | None | False | 29397.48 | 0 | 4099431 | 159699 | None | vol 2 pg no 14 item no 6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 7969.0 | 7969.0 | 29.73 | False | None | None | False | None | False | 236918.37 | 0 | 4099432 | 159699 | None | vol 2 pg no 14 item no 6.15 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1033.0 | 1033.0 | 3.15 | False | None | None | False | None | False | 3253.95 | 0 | 4099433 | 159699 | None | vol 1 pg no 15 item no 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates( | Cum | 6217.0 | 6217.0 | 2.47 | False | None | None | False | None | False | 15355.99 | 0 | 4099434 | 159699 | None | vol 2 pg no 81 item no 11.14.3.1 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer- in-charge: Profile E Fixing with adjustable lugs with split end tail to each jamb including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Mtr | 531.0 | 531.0 | 13.2 | False | None | None | False | None | False | 7009.2 | 0 | 4099435 | 159699 | None | vol 2 pg no 77 item no 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour,usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 4478.0 | 4478.0 | 5.04 | False | None | None | False | None | False | 22569.12 | 0 | 4099436 | 159699 | None | vol 2 pg no 79 item no 11.11.1 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 148.0 | 148.0 | 259.2 | False | None | None | False | None | False | 38361.6 | 0 | 4099437 | 159699 | None | vol 2 pg no 86 item no 11.34B | Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 183.0 | 183.0 | 181.44 | False | None | None | False | None | False | 33203.52 | 0 | 4099438 | 159699 | None | vol 2 pg no 41 item no 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 295.0 | 295.0 | 194.25 | False | None | None | False | None | False | 57303.75 | 0 | 4099439 | 159699 | None | vol 2 pg no 42 item no 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 371.0 | 371.0 | 171.29 | False | None | None | False | None | False | 63548.59 | 0 | 4099440 | 159699 | None | vol 2 pg no 64 item no 9.34 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1545.0 | 1545.0 | 109.22 | False | None | None | False | None | False | 168744.9 | 0 | 4099441 | 159699 | None | vol 2 pg no 50 item no 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 100.0 | 100.0 | 304.6 | False | None | None | False | None | False | 30460.0 | 0 | 4099442 | 159699 | None | vol 2 pg no 45 item no 8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 137.0 | 137.0 | 304.6 | False | None | None | False | None | False | 41730.2 | 0 | 4099443 | 159699 | None | vol 2 pg no 45 item no 8.27 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 53.0 | 53.0 | 148.7 | False | None | None | False | None | False | 7881.1 | 0 | 4099444 | 159699 | None | vol 2 pg no 45 item no 8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 89.0 | 89.0 | 148.7 | False | None | None | False | None | False | 13234.3 | 0 | 4099445 | 159699 | None | vol 2 pg no 48 item no 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 115.0 | 115.0 | 36.63 | False | None | None | False | None | False | 4212.45 | 0 | 4099446 | 159699 | None | vol 2 pg no 49 item no 8.49 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | cm | 4.0 | 4.0 | 2500.0 | False | None | None | False | None | False | 10000.0 | 0 | 4099447 | 159699 | None | vol 2 pg no 49 item no 8.43 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :Two coats on new work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 94.0 | 94.0 | 6.0 | False | None | None | False | None | False | 564.0 | 0 | 4099448 | 159699 | None | vol 2 pg no 151 item no 15.10 | Providing and Applying CFTRI approved two component flexible polymer modified acryli cementitious waterproofing coating with a mix ratio of (1 Liquid in2 Powder), to the RCC surface like bathroom, toilet, balcony & utility area applied @ 1.7kg/sqm in 2 coats to achieve 1mm DFT, having Elongation at break 50% as per ASTM D 412, Tensile strength greater than 1N/mm2 as per ASTM D 412, Adhesion strength: 0.80 N/mm2 as per ASTM D 4541, crack bridging upto 1mm as per ASTM C 836, Water penetration (5 bar pressure) as per BS EN 12390. The finished cost to include surface preparation, making coving of 50 mm 50mm at all right angles of wall Junction withPolymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. | Sqm | 367.0 | 367.0 | 106.15 | False | None | None | False | None | False | 38957.05 | 0 | 4099449 | 159699 | None | vol 2 pg no 125 item no 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes 100mm diameter. | Mtr | 291.0 | 291.0 | 18.0 | False | None | None | False | None | False | 5238.0 | 0 | 4099450 | 159699 | None | vol 2 pg no 82 item no 11.26.1 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kg | 138.0 | 138.0 | 387.45 | False | None | None | False | None | False | 53468.1 | 0 | 4099451 | 159699 | None | vol 2 pg no A19 item no 261 | Cuddapah Slabs 2.5 cms thick
| Sqm | 462.0 | 462.0 | 5.4 | False | None | None | False | None | False | 2494.8 | 0 |
| 1727506891000 | 0 | None | None | Buildings | Construction of two classroom to Govt Higher primary school in Hirehonalli village in kalghatagi tq dharwad Dist(Electrical Estimate) | 87922.56 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4099452 | 159700 | None | 1.2.1 | Concealed Conduit System :Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary19/20mm dia 2mm thick
| Mtr | 66.0 | 66.0 | 28.0 | False | None | None | False | None | False | 1848.0 | 0 | 4099453 | 159700 | None | 1.2.2 | Concealed Conduit System :Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick | Mtr | 78.0 | 78.0 | 8.0 | False | None | None | False | None | False | 624.0 | 0 | 4099454 | 159700 | None | 1.3.1 | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20mm dia 2mm thick | Mtr | 68.0 | 68.0 | 10.0 | False | None | None | False | None | False | 680.0 | 0 | 4099455 | 159700 | None | 1.3.2 | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick
| Mtr | 79.0 | 79.0 | 12.0 | False | None | None | False | None | False | 948.0 | 0 | 4099456 | 159700 | None | 1.9.2 | Supplying PVC/GI flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely25mm | Mtr | 22.0 | 22.0 | 4.0 | False | None | None | False | None | False | 88.0 | 0 | 4099457 | 159700 | None | 2.2.1 | Point wiring using Copper wire with out switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm (Phase&Neutral) &1x1.0 Sqmm(earth Wire)Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto3mtr from tapping point to out let via Switch | Point | 269.0 | 269.0 | 5.0 | False | None | None | False | None | False | 1345.0 | 0 | 4099458 | 159700 | None | 2.2.2 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch
| Point | 379.0 | 379.0 | 8.0 | False | None | None | False | None | False | 3032.0 | 0 | 4099459 | 159700 | None | 2.2.3 | Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box
| Point | 555.0 | 555.0 | 4.0 | False | None | None | False | None | False | 2220.0 | 0 | 4099460 | 159700 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,1.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP.
| Mtr | 26.0 | 26.0 | 30.0 | False | None | None | False | None | False | 780.0 | 0 | 4099461 | 159700 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,2.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP.
| Mtr | 42.0 | 42.0 | 65.0 | False | None | None | False | None | False | 2730.0 | 0 | 4099462 | 159700 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,4 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP.
| Mtr | 63.0 | 63.0 | 30.0 | False | None | None | False | None | False | 1890.0 | 0 | 4099463 | 159700 | None | 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,6 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP.
| Mtr | 92.0 | 92.0 | 4.0 | False | None | None | False | None | False | 368.0 | 0 | 4099464 | 159700 | None | 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box size 3way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
| Each | 159.0 | 159.0 | 4.0 | False | None | None | False | None | False | 636.0 | 0 | 4099465 | 159700 | None | 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box size 4-5way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
| Each | 177.0 | 177.0 | 2.0 | False | None | None | False | None | False | 354.0 | 0 | 4099466 | 159700 | None | 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box size 8way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
| Each | 261.0 | 261.0 | 4.0 | False | None | None | False | None | False | 1044.0 | 0 | 4099467 | 159700 | None | 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box size10-12way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
| Each | 319.0 | 319.0 | 4.0 | False | None | None | False | None | False | 1276.0 | 0 | 4099468 | 159700 | None | 3.4.8 | Supplying and flush mounting powder coated / galvanized metal box size 18way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
| Each | 405.0 | 405.0 | 4.0 | False | None | None | False | None | False | 1620.0 | 0 | 4099469 | 159700 | None | 3.5.2 | Supplying and fixing superior quality 3Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box.
| Each | 161.0 | 161.0 | 2.0 | False | None | None | False | None | False | 322.0 | 0 | 4099470 | 159700 | None | 3.5.3 | Supplying and fixing superior quality 4Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box.
| Each | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 | 4099471 | 159700 | None | 3.5.5 | Supplying and fixing superior quality 8Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox.
| Each | 284.0 | 284.0 | 2.0 | False | None | None | False | None | False | 568.0 | 0 | 4099472 | 159700 | None | 3.5.6 | Supplying and fixing superior quality 10-12Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox.
| Each | 344.0 | 344.0 | 3.0 | False | None | None | False | None | False | 1032.0 | 0 | 4099473 | 159700 | None | 3.5.8 | Supplying and fixing superior quality 18Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox.
| Each | 457.0 | 457.0 | 4.0 | False | None | None | False | None | False | 1828.0 | 0 | 4099474 | 159700 | None | 3.6.1 | Supplying and fixing of 6Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293.
| Each | 102.0 | 102.0 | 30.0 | False | None | None | False | None | False | 3060.0 | 0 | 4099475 | 159700 | None | 3.6.3 | Supplying and fixing of 6Amps 3way modular Socketc on existing modular switch plate as per IS 3854 and IS 1293.
| Each | 171.0 | 171.0 | 7.0 | False | None | None | False | None | False | 1197.0 | 0 | 4099476 | 159700 | None | 3.6.4 | Supplying and fixing of modular stepped electronic fan regulator on existing modular switch plate as per and IS 1293.
| Each | 357.0 | 357.0 | 7.0 | False | None | None | False | None | False | 2499.0 | 0 | 4099477 | 159700 | None | 3.6.7 | Supplying and fixing of 16Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293.
| Each | 180.0 | 180.0 | 2.0 | False | None | None | False | None | False | 360.0 | 0 | 4099478 | 159700 | None | 3.6.9 | Supplying and fixing of32Amps modular DP Switch on existing modular switch plate as per IS 3854 and IS 1293.
| Each | 326.0 | 326.0 | 2.0 | False | None | None | False | None | False | 652.0 | 0 | 4099479 | 159700 | None | 3.6.10 | Supplying and fixing of6/16amps modular Universal Socket on existing modular switch plate as per IS 3854 and IS 1293.
| Each | 236.0 | 236.0 | 2.0 | False | None | None | False | None | False | 472.0 | 0 | 4099480 | 159700 | None | 3.14.7 | Supplying and fixing of 6Amps Batten holder on existing board.
| No | 74.0 | 74.0 | 7.0 | False | None | None | False | None | False | 518.0 | 0 | 4099481 | 159700 | None | 5.7.3 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.63amps
| Each | 401.0 | 401.0 | 4.0 | False | None | None | False | None | False | 1604.0 | 0 | 4099482 | 159700 | None | 5.18.1 | Supplying and fixingof 6to32 Amps Single pole miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
| Each | 415.0 | 415.0 | 4.0 | False | None | None | False | None | False | 1660.0 | 0 | 4099483 | 159700 | None | 5.18.4 | Supplying and fixingof 6to32 Amps Double pole miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
| Each | 739.0 | 739.0 | 2.0 | False | None | None | False | None | False | 1478.0 | 0 | 4099484 | 159700 | None | 5.18.9 | Supplying and fixing 12way regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - doble Door12way sp&n
| Each | 2329.0 | 2329.0 | 2.0 | False | None | None | False | None | False | 4658.0 | 0 | 4099485 | 159700 | None | 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm allround the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia | Each | 3510.0 | 3510.0 | 2.0 | False | None | None | False | None | False | 7020.0 | 0 | 4099486 | 159700 | None | 32.05Hescom SR | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)
| Km | 141842.0 | 141842.0 | 0.02 | False | None | None | False | None | False | 2836.84 | 0 | 4099487 | 159700 | None | 21.05Hescom SR | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 Sqmm
| Km | 20886.0 | 20886.0 | 0.02 | False | None | None | False | None | False | 417.72 | 0 | 4099488 | 159700 | None | 1.4.1Vol-1 | Earth work excavation by manual means for drains, canals, waste weir, draft,
approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights, removal
of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of
labour, tools & other appurtenaces required to complete the work. Depth upto 1.50m | Cum | 242.0 | 242.0 | 7.0 | False | None | None | False | None | False | 1694.0 | 0 | 4099489 | 159700 | None | 9Page No-176 WRD | Providing and fixing perforated 50 mm dia. GI pipes 'A' class in drilled holes
for drainage including cost of all materials, machinery, labour, making
perforations, providing flap valve and jointing etc.,complete with all leads
and lifts. (For Dam and Allied works)"
| Mtr | 543.0 | 543.0 | 4.0 | False | None | None | False | None | False | 2172.0 | 0 | 4099490 | 159700 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Economy model
| Each | 2984.0 | 2984.0 | 4.0 | False | None | None | False | None | False | 11936.0 | 0 | 4099491 | 159700 | None | 11.3.2 | LED Indoor Supplying of 1x4' feet - LED PVC Square Batten 20/22W with high quality diffuser with Life of 25000 burning hours & 70% Greater thanlumen maintenance with CRI 80. Power Input: 220-240V @ 50Hz & Power factor greaterthan0.9 along with CE approved drivers. 2 years Warranty against any manufacturing defect working under standard electrical condition
| Each | 690.0 | 690.0 | 7.0 | False | None | None | False | None | False | 4830.0 | 0 | 4099492 | 159700 | None | 11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .40.W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.
| Each | 4024.0 | 4024.0 | 2.0 | False | None | None | False | None | False | 8048.0 | 0 | 4099493 | 159700 | None | 11.11.4 | Supplying & fixing of retrofit type - LED bulb . W with OPAL
acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per
LM 79. The operating input voltage should be between 130 to275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.9W, 6500K" | Each | 154.0 | 154.0 | 7.0 | False | None | None | False | None | False | 1078.0 | 0 | 4099494 | 159700 | None | 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.
| Each | 122.0 | 122.0 | 7.0 | False | None | None | False | None | False | 854.0 | 0 | 4099495 | 159700 | None | 13.1 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.
| Mtr | 315.0 | 315.0 | 3.0 | False | None | None | False | None | False | 945.0 | 0 | 4099496 | 159700 | None | 13.12 | Extra length of GI pipe of class B 19mm dia for down rod.
| Each | 197.0 | 197.0 | 2.0 | False | None | None | False | None | False | 394.0 | 0 | 4099497 | 159700 | None | 13.1.1 | Supplying and Fixing of.mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to this bracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires.Using 25mm dia G.I.Pipe
| Each | 978.0 | 978.0 | 2.0 | False | None | None | False | None | False | 1956.0 | 0 |
|
|
---|