createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1727515338118
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee530.00
emd50000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose09-10-2024 16:00:00
tenderQueryClose08-10-2024 17:00:00
technicalBidOpenNone
publishedDate28-09-2024 15:01:49
publishedByPostRDPR_EE_DIV_CKD
publishedByUserKPE10445 - PRAVEEN MATHAPATI
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSUBHAM KOLI
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08338272131
mobileNumber8197629009
tenderSupplierListNone
tenderSchedule
createdTs1727515338170
version4
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT8857
titleConstruction of New Anganwadi Building No 34 in Navgram at Karoshi village in Chikodi Taluka
descriptionBuilding
categoryWORKS
categoryTextWorks
ecv2115190.36
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location828
locationNameRDPR Division Office Chikkodi
provisionalAmount2500000.0
groupOverheadTotalNone
fileNumberRDPR/DMF/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17275153380000NoneNoneBuildingsConstruction of New Anganwadi Building No 34 in Navgram at Karoshi village in Chikodi Taluka1748406.61
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4100631159772Nonecode01Earth work in surface excavation by mechanical means for lowering & levelingthe ground for all works other than foundation in all kinds of soils & upto depthnot exceeding 300mm as per drawing and technical specifications, includingsetting out, shoring, strutting, barricading, caution lights, removal of stumpsand other deleterious matter including dressing of excavated surfaces, disposingoff or levelling the excavated earth or sorting & stacking the selected earth forreuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth complete as per direction of the Engineer-in-charge of the workSqm99.7599.75109.25FalseNoneNoneFalseNoneFalse10897.68750
4100632159772Nonecode02Earth work excavation for Foundation by mechanical means for all works &depth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the excavated earth or sorting& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenacesrequired to complete the work In all kinds of soils Depth upto 3 m complete as per direction of the Engineer-in-charge of the workCum381.15381.1544.9FalseNoneNoneFalseNoneFalse17113.6350
4100633159772Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the workCum6288.456288.456.09FalseNoneNoneFalseNoneFalse38296.66050
4100634159772Nonecode04Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the workCum6652.86652.89.06FalseNoneNoneFalseNoneFalse60274.3680
4100635159772Nonecode05Formwork & Centring Charges @ 8% complete as per direction of the Engineer-in-charge of the workCum532.25532.259.06FalseNoneNoneFalseNoneFalse4822.1850
4100636159772Nonecode06Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the workCum6652.86652.86.44FalseNoneNoneFalseNoneFalse42844.0320
4100637159772Nonecode07Formwork & Centring Charges @ 70% complete as per direction of the Engineer-in-charge of the workCum4656.964656.961.52FalseNoneNoneFalseNoneFalse7078.57920
4100638159772Nonecode08Formwork & Centring Charges @ 50% complete as per direction of the Engineer-in-charge of the workCum3326.43326.44.92FalseNoneNoneFalseNoneFalse16365.8880
4100639159772Nonecode09Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the workCum7185.157185.1511.07FalseNoneNoneFalseNoneFalse79539.61050
4100640159772Nonecode10Formwork & Centring Charges @ 70% complete as per direction of the Engineer-in-charge of the workCum5029.615029.613.86FalseNoneNoneFalseNoneFalse19414.29460
4100641159772Nonecode11Formwork & Centring Charges @ 60% complete as per direction of the Engineer-in-charge of the workCum4311.094311.097.21FalseNoneNoneFalseNoneFalse31082.95890
4100642159772Nonecode12Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the workCum7185.157185.150.28FalseNoneNoneFalseNoneFalse2011.8420
4100643159772Nonecode13Formwork & Centring Charges @ 45% complete as per direction of the Engineer-in-charge of the workCum3233.323233.320.28FalseNoneNoneFalseNoneFalse905.32960
4100644159772Nonecode14Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per direction of the Engineer-in-charge of the workCum7185.157185.153.95FalseNoneNoneFalseNoneFalse28381.34250
4100645159772Nonecode15Formwork & Centring Charges @ 50% complete as per direction of the Engineer-in-charge of the workCum3592.583592.583.95FalseNoneNoneFalseNoneFalse14190.6910
4100646159772Nonecode16Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) complete as per direction of the Engineer-in-charge of the workCum6948.96948.98.26FalseNoneNoneFalseNoneFalse57397.9140
4100647159772Nonecode17Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (1 cement : 6 coarse sand) complete as per direction of the Engineer-in-charge of the workCum6515.256515.255.58FalseNoneNoneFalseNoneFalse36355.0950
4100648159772Nonecode18Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.complete as per direction of the Engineer-in-charge of the workCum8367.458367.4526.98FalseNoneNoneFalseNoneFalse225753.8010
4100649159772Nonecode19Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. complete as per direction of the Engineer-in-charge of the workTonne93929.8593929.852.4FalseNoneNoneFalseNoneFalse225431.640
4100650159772Nonecode20Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. complete as per direction of the Engineer-in-charge of the workCum279.3279.363.52FalseNoneNoneFalseNoneFalse17741.1360
4100651159772Nonecode21Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork shall be paid separately) complete as per direction of the Engineer-in-charge of the workCum6527.856527.857.82FalseNoneNoneFalseNoneFalse51047.7870
4100652159772Nonecode22Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fne sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge.Sqm292.95292.95283.66FalseNoneNoneFalseNoneFalse83098.1970
4100653159772Nonecode23Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) fnished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fne sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge.Sqm389.55389.55106.57FalseNoneNoneFalseNoneFalse41514.34350
4100654159772Nonecode24Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm105.0105.0283.66FalseNoneNoneFalseNoneFalse29784.30
4100655159772Nonecode25Providing and laying Polished Glazed Vitrifed tiles in Floor with different sizes (thickness to be specifed by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modifed quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x1200 mmSqm1392.31392.390.74FalseNoneNoneFalseNoneFalse126337.3020
4100656159772Nonecode26Providing and fxing glazed screen printed border tile 75mm wide having thickness 5mm, of approved quality & make, in all shades, design and prints, in dado, over 12mm thick bed of cement mortar 1:3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3 kg/m2 including pointing with white cement mixed with pigment of matching shade, all complete as approved by Engineer - in - Charge.m142.8142.8120.0FalseNoneNoneFalseNoneFalse17136.00
4100657159772Nonecode27Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Sqm2994.62994.612.35FalseNoneNoneFalseNoneFalse36983.310
4100658159772Nonecode28Providing and fxing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.Kg176.4176.4189.0FalseNoneNoneFalseNoneFalse33339.60
4100659159772Nonecode29Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wallthickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm.Sqm7070.77070.79.0FalseNoneNoneFalseNoneFalse63636.30
4100660159772Nonecode30Supply and Installation of Multicell Standing Seam polycarbonate panels having flux 7.0 as per EN 16153 & EN ISO 10077-2. For min joints, panel shall be 1000 - 1200 mm wide with standing seam on both sides. Panels shall have minimum six-seven layers with truss bridge design for higher flexibility and strength. The system shall be secured using suitable connectors with double tooth grip lock locking mechanism and fixed on purlin(to be paid separately) having a pull out load of min 7000N tested as per ISO 6892-1998 and IS 1608-2005. Panels must satisfy impact test as per IS 14443-97 shall show no sign of breakage which have been exposed to UV for 500 Hours (min) as per ASTM G 155. Panels shall have Yellowness Index of not more than 15 units as per ASTM D 1925 when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. Panel shall be closed at the end with additional Aluminium U profile as required. All aluminium should be factory finished / mill finished. Panel shall be fixed over MS structural steel / MS purlin (to be paid separately) conforming to the details in the specificationsSqm4084.54084.513.03FalseNoneNoneFalseNoneFalse53221.0350
4100661159772Nonecode31Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challengedKg593.25593.2537.8FalseNoneNoneFalseNoneFalse22424.850
4100662159772Nonecode32Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. --do-- sal wood frames.Cum103755.75103755.750.54FalseNoneNoneFalseNoneFalse56028.1050
4100663159772Nonecode33Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifcations.Nos1066.81066.85.0FalseNoneNoneFalseNoneFalse5334.00
4100664159772Nonecode34Providing and fxing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifcations. (excluding cost of fxtures)Sqm7241.857241.8515.2FalseNoneNoneFalseNoneFalse110076.120
4100665159772Nonecode35Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge.Sqm143.85143.85283.66FalseNoneNoneFalseNoneFalse40804.4910
4100666159772Nonecode36Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-chargeSqm297.15297.15106.57FalseNoneNoneFalseNoneFalse31667.27550
4100667159772Nonecode37Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge.Sqm144.9144.969.53FalseNoneNoneFalseNoneFalse10074.8970
17275153380000NoneNoneBuildingsElectrification51863.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4100668159773Nonecode01Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required. 25mm complete as per direction of the Engineer-in-charge of the workMtr35.035.080.0FalseNoneNoneFalseNoneFalse2800.00
4100669159773Nonecode02Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPERconductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A Short point upto 3Mtr from tapping point to out let via switch box complete as per direction of the Engineer-in-charge of the workPoint285.0285.06.0FalseNoneNoneFalseNoneFalse1710.00
4100670159773Nonecode03Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box complete as per direction of the Engineer-in-charge of the workPoint394.0394.03.0FalseNoneNoneFalseNoneFalse1182.00
4100671159773Nonecode04Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box complete as per direction of the Engineer-in-charge of the workPoint570.0570.01.0FalseNoneNoneFalseNoneFalse570.00
4100672159773Nonecode05Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS694: 1990 & confirming to GTP of GROUP A. 1.5 sqmm complete as per direction of the Engineer-in-charge of the workMtr26.026.050.0FalseNoneNoneFalseNoneFalse1300.00
4100673159773Nonecode062.5 sqmm complete as per direction of the Engineer-in-charge of the workMtr42.042.080.0FalseNoneNoneFalseNoneFalse3360.00
4100674159773Nonecode07Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way complete as per direction of the Engineer-in-charge of the workEach261.0261.04.0FalseNoneNoneFalseNoneFalse1044.00
4100675159773Nonecode0810-12Way complete as per direction of the Engineer-in-charge of the workEach319.0319.08.0FalseNoneNoneFalseNoneFalse2552.00
4100676159773Nonecode09Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module complete as per direction of the Engineer-in-charge of the workEach284.0284.04.0FalseNoneNoneFalseNoneFalse1136.00
4100677159773Nonecode1010-12 Module complete as per direction of the Engineer-in-charge of the workEach344.0344.08.0FalseNoneNoneFalseNoneFalse2752.00
4100678159773Nonecode11Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A. 6 Amps one way Switch complete as per direction of the Engineer-in-charge of the workEach102.0102.015.0FalseNoneNoneFalseNoneFalse1530.00
4100679159773Nonecode126Amps 3 way Socket complete as per direction of the Engineer-in-charge of the workEach171.0171.04.0FalseNoneNoneFalseNoneFalse684.00
4100680159773Nonecode13Stepped fan Regulator complete as per direction of the Engineer-in-charge of the workEach357.0357.03.0FalseNoneNoneFalseNoneFalse1071.00
4100681159773Nonecode1432 Amps Dp switch complete as per direction of the Engineer-in-charge of the workEach326.0326.02.0FalseNoneNoneFalseNoneFalse652.00
4100682159773Nonecode15Supplying & Fixing of 70-150 W lamp holder 2 Pin complete as per direction of the Engineer-in-charge of the workEach63.063.030.0FalseNoneNoneFalseNoneFalse1890.00
4100683159773Nonecode16Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 16Amps complete as per direction of the Engineer-in-charge of the workEach157.0157.02.0FalseNoneNoneFalseNoneFalse314.00
4100684159773Nonecode17Supplying and fixing of Shunt trip suitable for MCCB.CBCT. complete as per direction of the Engineer-in-charge of the workEach1703.01703.01.0FalseNoneNoneFalseNoneFalse1703.00
4100685159773Nonecode18Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5-32 Amps SP complete as per direction of the Engineer-in-charge of the workEach415.0415.02.0FalseNoneNoneFalseNoneFalse830.00
4100686159773Nonecode19Supplying and fixing of 5'-80 W of T8 Fluorescent Tube with 54W power consumption with low 3mg Mercury content less phosphor coating Operating voltage range from 180V to 265V, 50Hz AC power Supply. complete as per direction of the Engineer-in-charge of the workEach520.0520.010.0FalseNoneNoneFalseNoneFalse5200.00
4100687159773Nonecode20Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / Watt, Three Blades of blade leaf 1.05mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty 48" Sweep 5 Star (1200 mm) complete as per direction of the Engineer-in-charge of the workEach2677.02677.03.0FalseNoneNoneFalseNoneFalse8031.00
4100688159773Nonecode21Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. (on wall/ceiling/rafter/girders complete as per direction of the Engineer-in-charge of the workEach122.0122.035.0FalseNoneNoneFalseNoneFalse4270.00
4100689159773Nonecode22Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 10sqmm complete as per direction of the Engineer-in-charge of the workMtr167.0167.025.0FalseNoneNoneFalseNoneFalse4175.00
4100690159773Nonecode23Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts, 50Hz AC supply & completely wired on existing box complete as per direction of the Engineer-in-charge of the workEach646.0646.01.0FalseNoneNoneFalseNoneFalse646.00
4100691159773Nonecode24LT AC Single Phase 2 Wire, 5-30 Amps Smart Energy Meter, Class 1.0 Accuracy with RF Communication Module complete as per direction of the Engineer-in-charge of the workEach2461.02461.01.0FalseNoneNoneFalseNoneFalse2461.00
17275153380000NoneNoneBuildingsBORE WELL88261.95
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4100692159774Nonecode01Sinking of Borewell of 150 mm dia clear using fast rig in all strata including over burden upto 20mtr, fixing of casting pipes, collars and cap and with necessary cutting and throding including transportation of rig and supporting vehicles, crcharges and cost of consumable etc., complete (casing pipes, collars and caps will be supplied departmentally)including yield testing at the final depth with a minimum continuous working of compressor for one hour for P.W.S. and M.W.S. Scheme only Up to 50 Mtrs complete as per direction of the Engineer-in-charge of the workMtr324.45324.4550.0FalseNoneNoneFalseNoneFalse16222.50
4100693159774Nonecode02Above 50 Mtrs & Upto 100 Mtrs complete as per direction of the Engineer-in-charge of the workMtr406.35406.3550.0FalseNoneNoneFalseNoneFalse20317.50
4100694159774Nonecode03Above 100 Mtrs & Upto 150 Mtrs complete as per direction of the Engineer-in-charge of the workMtr432.6432.650.0FalseNoneNoneFalseNoneFalse21630.00
4100695159774Nonecode04Above 150 Mtrs to 200 Mtrs complete as per direction of the Engineer-in-charge of the workMtr501.9501.950.0FalseNoneNoneFalseNoneFalse25095.00
4100696159774Nonecode05Providing and fixing ISI marked 150 mm dia NB medium black ERW casing pipe 'B' Class black electric resistance continuous welded MS tube Medium Grade, confirming to ISI 1239 (Part-I)/1990 Amendments 1-5 with latest amendments if any in random length of 4 to 7 mtrs. Both ends threaded confirming to IS 554/1985, one end fitted with socket and the other end with a plastic protection ring, pipe supplied should be with ISI marking, weghing 19.50 Kg/m complete as per direction of the Engineer-in-charge of the workMtr964.95964.955.0FalseNoneNoneFalseNoneFalse4824.750
4100697159774Nonecode06Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). Thedimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments cluding cost of material and labour charges for fixing, if any etc. complete with all lead and lifts complete as per direction of the Engineer-in-charge of the workEach172.2172.21.0FalseNoneNoneFalseNoneFalse172.20
17275153380000NoneNoneBuildingsPUMPING MACHINERY199020.7
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4100698159775Nonecode01Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments nd instructions of engineer 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.00" as per direction of the Engineer-in-charge of the workEach24326.424326.41.0FalseNoneNoneFalseNoneFalse24326.40
4100699159775Nonecode02Supply of Outdoor type for Three phase pumpsets the panel must be with ISI makred capacitor of suitable capacity and must have indicator lamps, volmeter, ammeter etc., complete with proper terminal marking with all lead and lifts etc complete as per direction of the Engineer-in-charge of the workSet14500.014500.01.0FalseNoneNoneFalseNoneFalse14500.00
4100700159775Nonecode03Supplying and drawing 3 core flat PVC sheathed submersible pumpcable manufactured with electrolytic grade copper with flexible copperwith low resistance conductor confirming to13:8130-1984 and virgingrade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts 3C x 4 mm2 complete as per direction of the Engineer-in-charge of the workMtr176.4176.4150.0FalseNoneNoneFalseNoneFalse26460.00
4100701159775Nonecode04Supply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments a) 63 mm Dia complete as per direction of the Engineer-in-charge of the workEach436.8436.81.0FalseNoneNoneFalseNoneFalse436.80
4100702159775Nonecode05Supply and delivery at site of brand new best make gate valve as per IS 778/1984 wit a) 50 mm Dia complete as per direction of the Engineer-in-charge of the workEach1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
4100703159775Nonecode06The Non Return Valve (NRV) assembly complet complete as per direction of the Engineer-in-charge of the workNo682.5682.51.0FalseNoneNoneFalseNoneFalse682.50
4100704159775Nonecode07Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets complete as per direction of the Engineer-in-charge of the workKvar577.5577.53.0FalseNoneNoneFalseNoneFalse1732.50
4100705159775Nonecode08Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box complete as per direction of the Engineer-in-charge of the workNo1207.51207.51.0FalseNoneNoneFalseNoneFalse1207.50
4100706159775Nonecode09Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints 50 mm dia C PVC. pipes complete as per direction of the Engineer-in-charge of the workMtr820.05820.05150.0FalseNoneNoneFalseNoneFalse123007.50
4100707159775Nonecode10Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge a) Out door type complete as per direction of the Engineer-in-charge of the workJob1417.51417.51.0FalseNoneNoneFalseNoneFalse1417.50
4100708159775Nonecode11Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as perclause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes complete as per direction of the Engineer-in-charge of the workJob3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
17275153380000NoneNoneBuildingsWater supply And Sanitation27638.1
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4100709159776Nonecode01Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required complete as per direction of the Engineer-in-charge of the workNo2982.02982.01.0FalseNoneNoneFalseNoneFalse2982.00
4100710159776Nonecode02Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 mm complete as per direction of the Engineer-in-charge of the workNo2447.552447.551.0FalseNoneNoneFalseNoneFalse2447.550
4100711159776Nonecode03Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require complete as per direction of the Engineer-in-charge of the workNo2203.952203.951.0FalseNoneNoneFalseNoneFalse2203.950
4100712159776Nonecode04Providing and fixing C.P. brass bib cock of approved quality conforming complete as per direction of the Engineer-in-charge of the workNo666.75666.754.0FalseNoneNoneFalseNoneFalse2667.00
4100713159776Nonecode05Providing and fixing Chlorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this including the pipe with clamp at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete .(internal work exposed on wall) 25mm nominal OD Pipe complete as per direction of the Engineer-in-charge of the workm191.1191.110.0FalseNoneNoneFalseNoneFalse1911.00
4100714159776Nonecode06Providing and fixing Chlorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this including the pipe with clamp at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete .(internal work exposed on wall) 25mm nominal OD Pipe complete as per direction of the Engineer-in-charge of the workm420.0420.010.0FalseNoneNoneFalseNoneFalse4200.00
4100715159776Nonecode07Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavationetc complete as per direction of the Engineer-in-charge of the workm296.1296.16.0FalseNoneNoneFalseNoneFalse1776.60
4100716159776Nonecode08Providing and placing on terrace (at floor levels) polyethylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and makin neceddary holes for inlet,outlet and overflow pipes but without fittings and and the base support for tank complete as per direction of the Engineer-in-charge of the workLtr9.459.451000.0FalseNoneNoneFalseNoneFalse9450.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17275153390000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17275153390001NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of KarnatakaNone
17275153390001NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17275153390000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17275153390000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17275153390001NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitches at bidders end.None
17275153390001NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17275153390001NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17275153390001NoneNoneELIGIBILITYFor Details Refer Tender Notification And Conditions In The Bid Documents.None
17275153390001NoneNoneELIGIBILITYAcceptence / Cancellation of the works are reserved by under signed without any reasons for the same.None
17275153390001NoneNoneELIGIBILITYExecutive Engineer PRED Chikodi has authority to accept or reject any tender without assigning reason.None
17275153390001NoneNoneELIGIBILITYCorrigendum / modifications / correction, if any, will be published in the website only.None
17275153390001NoneNoneELIGIBILITYTo qualify for award of this contract, each tenderer should give all details and documents as per Technical and Financial bid attached to this tender.None
17275153390001NoneNoneELIGIBILITYIncomplete / conditional tenders will not be accepted.None
17275153390001NoneNoneELIGIBILITYTenderer must submit his present accurate postal address and phone / cell phone numberNone
17275153390001NoneNoneELIGIBILITYThe tender may be cancelled at any stage without assigning any reasonNone
17275153390001NoneNoneELIGIBILITYAny objection regarding the tender must be submitted directly to Executive Engineer , not in inward.None
17275154390000NoneNoneELIGIBILITYFor interpretations of clauses, conditions, spelling mistakes, etc., decision of Executive Engineer, PRED, Chikodi is final.None
17275154420000NoneNoneELIGIBILITYSuccessful bidder submitting bids below the amount put to tender will be regularized to submit the difference amount in the form of FDR/TDR/DD/Pledge on the name of EE PRED Chikodi within 20 days from the date of receiving the letter of acceptance. additional security paid for unbalanced tenders Failing which EMD will be forfeited and further action will be taken as per G O No FD PCL 2008 Bangalore Dated 14/10/2008.None
17275154450000NoneNoneELIGIBILITYWork shall be executed as per KTPP Act & kw Tender Conditions.None
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Contractor KPWD Civil Registration CertificateTrueTechnical Bid
Annual Turn Over Certificate Rs.21.15 Lakhs from 2019-20 to 2023-24TrueTechnical Bid
Similar Nature of Work Done Rs.11.00 Lakhs CertificateTrueTechnical Bid
GST RegistrationTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsBelagaviChikodiChikkodiCHIKKODI (SC)Karoshi villageNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone