4087407 | 159149 | None | code01 | Earth work excavation by manual means for drains,canals and similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, re moval of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sort ing & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work | Cum | 242.0 | 242.0 | 42.53 | False | None | None | False | None | False | 10292.26 | 0 |
4087408 | 159149 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 5664.0 | 5664.0 | 5.18 | False | None | None | False | None | False | 29339.52 | 0 |
4087409 | 159149 | None | code03 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates | Cum | 6287.0 | 6287.0 | 11.04 | False | None | None | False | None | False | 69408.48 | 0 |
4087410 | 159149 | None | code04 | For Centering according to the Table For Finished Concrete Foundation and substucture | Cum | 314.35 | 314.35 | 11.04 | False | None | None | False | None | False | 3470.424 | 0 |
4087411 | 159149 | None | code05 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates | Cum | 6630.0 | 6630.0 | 16.57 | False | None | None | False | None | False | 109859.1 | 0 |
4087412 | 159149 | None | code06 | For Centering according to the Table For Finished Concrete column | Cum | 4641.0 | 4641.0 | 3.41 | False | None | None | False | None | False | 15825.81 | 0 |
4087413 | 159149 | None | code07 | For Centering according to the Table For Finished Concrete plinth beam | Cum | 3315.0 | 3315.0 | 1.24 | False | None | None | False | None | False | 4110.6 | 0 |
4087414 | 159149 | None | code08 | For Centering according to the Table For Finished Concrete Beam | Cum | 3978.0 | 3978.0 | 4.56 | False | None | None | False | None | False | 18139.68 | 0 |
4087415 | 159149 | None | code09 | For Centering according to the Table For Finished Concrete Slab | Cum | 3315.0 | 3315.0 | 7.17 | False | None | None | False | None | False | 23768.55 | 0 |
4087416 | 159149 | None | code10 | For Centering according to the Table For Finished Concrete Chejja | Cum | 2983.5 | 2983.5 | 0.18 | False | None | None | False | None | False | 537.03 | 0 |
4087417 | 159149 | None | code11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(The laps and wastages shall not be measured separately) | Kg | 89.46 | 89.46 | 2369.14 | False | None | None | False | None | False | 211943.2644 | 0 |
4087418 | 159149 | None | code12 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 7978.0 | 7978.0 | 6.2 | False | None | None | False | None | False | 49463.6 | 0 |
4087419 | 159149 | None | code13 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 8211.0 | 8211.0 | 20.07 | False | None | None | False | None | False | 164794.77 | 0 |
4087420 | 159149 | None | code14 | Construction of Embankment by excavating the available approved Gravel / Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.(The laps and wastages shall not be measured separately) | Cum | 474.0 | 474.0 | 44.18 | False | None | None | False | None | False | 20941.32 | 0 |
4087421 | 159149 | None | code15 | Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 ce ment : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge | Cum | 6666.0 | 6666.0 | 10.55 | False | None | None | False | None | False | 70326.3 | 0 |
4087422 | 159149 | None | code16 | Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications | Sqm | 1636.0 | 1636.0 | 59.43 | False | None | None | False | None | False | 97227.48 | 0 |
4087423 | 159149 | None | code17 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 333.0 | 333.0 | 249.65 | False | None | None | False | None | False | 83133.45 | 0 |
4087424 | 159149 | None | code18 | Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 ce ment : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge | Sqm | 241.0 | 241.0 | 50.56 | False | None | None | False | None | False | 12184.96 | 0 |
4087425 | 159149 | None | code19 | Poviding and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge | Sqm | 100.0 | 100.0 | 114.36 | False | None | None | False | None | False | 11436.0 | 0 |
4087426 | 159149 | None | code20 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge | Sqm | 158.0 | 158.0 | 262.95 | False | None | None | False | None | False | 41546.1 | 0 |
4087427 | 159149 | None | code21 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 ems c/c both horizontally and vertically fixed with chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work HOM curing, complete as per specifications.Specification | Sqm | 1238.0 | 1238.0 | 5.04 | False | None | None | False | None | False | 6239.52 | 0 |
4087428 | 159149 | None | code22 | Providing and fixing M.S. grills of required pattern in frames of win dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc | Kg | 183.0 | 183.0 | 113.4 | False | None | None | False | None | False | 20752.2 | 0 |
4087429 | 159149 | None | code23 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications | Cum | 138074.0 | 138074.0 | 0.05 | False | None | None | False | None | False | 6903.7 | 0 |
4087430 | 159149 | None | code24 | Providing and fixing in position fully panelled Honne wood shutters for doors with ,stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials,labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 7085.0 | 7085.0 | 1.81 | False | None | None | False | None | False | 12823.85 | 0 |
4087431 | 159149 | None | code25 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. | Sqm | 6734.0 | 6734.0 | 5.4 | False | None | None | False | None | False | 36363.6 | 0 |
4087432 | 159149 | None | code26 | Providing and Fixing Fixtures for Door Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. | Each | 55.0 | 55.0 | 20.0 | False | None | None | False | None | False | 1100.0 | 0 |
4087433 | 159149 | None | code27 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. 10.6.3 Wedge expansion type Fastener with | Each | 60.0 | 60.0 | 20.0 | False | None | None | False | None | False | 1200.0 | 0 |
4087434 | 159149 | None | code28 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | Each | 237.0 | 237.0 | 10.0 | False | None | None | False | None | False | 2370.0 | 0 |
4087435 | 159149 | None | code29 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc.
Complete | Each | 130.0 | 130.0 | 22.0 | False | None | None | False | None | False | 2860.0 | 0 |
4087436 | 159149 | None | code30 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42mm with suitable washers weighing not less than 33 gms | Each | 55.0 | 55.0 | 4.0 | False | None | None | False | None | False | 220.0 | 0 |
4087437 | 159149 | None | code31 | Providing and fixing on wall face unplasticized Rigid PVC rain water pipes Confirming IS : 13592 Type A, including Jointing with seal ring Confirming IS : 5382, leaving 10mm gap for thermal Expansion i) Single socketed pipes 75mm diameters | m | 197.0 | 197.0 | 10.0 | False | None | None | False | None | False | 1970.0 | 0 |
4087438 | 159149 | None | code32 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube
including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kg | 138.0 | 138.0 | 68.75 | False | None | None | False | None | False | 9487.5 | 0 |
4087439 | 159149 | None | code33 | Electrification Work : Supplying and wiring adopting loop system in existing PVC Conduit/casing caping using 1100V grade,copper conductor fexibele multistrand FRLS PVC insulated, 2 x 1.5 Sqmm cable conferming to GTP,with a 6AMPS flush type SP Controll switch shal be fixed on existing plastic sheet or Gang box, the other end of the wires shall be terminated wiht sufficeint loose length in a wood or PVC round block. complete for each outlet.---do ----a)Shrot Point upto 3mtr from taping point to outlet via switch | Nos | 285.0 | 285.0 | 10.0 | False | None | None | False | None | False | 2850.0 | 0 |
4087440 | 159149 | None | code34 | Mediumpoint above 3Mtr upto 6Mtr from tapping point to out let via switch | Nos | 394.0 | 394.0 | 8.0 | False | None | None | False | None | False | 3152.0 | 0 |
4087441 | 159149 | None | code35 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in a existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654. -do- 6 Amps 3/5 Way | Nos | 143.0 | 143.0 | 10.0 | False | None | None | False | None | False | 1430.0 | 0 |
4087442 | 159149 | None | code36 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. -do- 10"x7"x3" (254x178x76mm) | Nos | 112.0 | 112.0 | 2.0 | False | None | None | False | None | False | 224.0 | 0 |
4087443 | 159149 | None | code37 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300mm …. etc. as required.25mm | m | 35.0 | 35.0 | 25.0 | False | None | None | False | None | False | 875.0 | 0 |
4087444 | 159149 | None | code38 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper conductor single core wire in open or concealed system of wiring as per IS-694:1990 & confirming to GTP of GROUP-B.-do- 1.5 Sqmm | m | 26.0 | 26.0 | 50.0 | False | None | None | False | None | False | 1300.0 | 0 |
4087445 | 159149 | None | code39 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 415.0 | 415.0 | 2.0 | False | None | None | False | None | False | 830.0 | 0 |
4087446 | 159149 | None | code40 | Supplying of recess mounting non integrated type LEDdown light...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceilingclA, LED of Power/COB with CCT 6500 degree K, CRI | Each | 1671.0 | 1671.0 | 2.0 | False | None | None | False | None | False | 3342.0 | 0 |
4087447 | 159149 | None | code41 | Fixing all types and all capacities fluorescent/false ceiling/spot light/CFL fittings indoor on the wall / ceiling/ rafters/girders using 23/0.0076" twin twisted PVC insulated wires, required nos of round blocks and clamps. -do- On wall/ceiling/Rafter/Girders | Each | 119.0 | 119.0 | 10.0 | False | None | None | False | None | False | 1190.0 | 0 |
4087448 | 159149 | None | code42 | Fixing a ceiling/wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring | Each | 171.0 | 171.0 | 4.0 | False | None | None | False | None | False | 684.0 | 0 |
4087449 | 159149 | None | code43 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.-do- 56" Sweep (1400mm). Economy model | Each | 3031.0 | 3031.0 | 2.0 | False | None | None | False | None | False | 6062.0 | 0 |
4087450 | 159149 | None | code44 | Supplying And Fixing of modular switch/stepped electroniv fan regulator on existing modular switch as per IS 3854 And IS 1293 Group A | Each | 357.0 | 357.0 | 2.0 | False | None | None | False | None | False | 714.0 | 0 |
4087451 | 159149 | None | code45 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90 thick GI pipe 2.5mtr long buried in a pit. The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 122mm dia | Each | 3510.0 | 3510.0 | 1.0 | False | None | None | False | None | False | 3510.0 | 0 |