3937575 | 152195 | None | 2.5.2 | COLUMNS-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
| Cum | 12336.9 | 12336.9 | 8.69 | False | None | None | False | None | False | 107207.661 | 0 |
3937576 | 152195 | None | 2.5.2 | RCC BEAMS-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
| Cum | 11611.2 | 11611.2 | 10.46 | False | None | None | False | None | False | 121453.152 | 0 |
3937577 | 152195 | None | 2.5.2 | RCC SLAB-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
| Cum | 10885.5 | 10885.5 | 17.86 | False | None | None | False | None | False | 194415.03 | 0 |
3937578 | 152195 | None | 2.5.2 | LINTELS-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
| Cum | 11611.2 | 11611.2 | 2.0 | False | None | None | False | None | False | 23222.4 | 0 |
3937579 | 152195 | None | 2.5.2 | STAIRCASE-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
| Cum | 10885.5 | 10885.5 | 2.5 | False | None | None | False | None | False | 27213.75 | 0 |
3937580 | 152195 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
| Cum | 10195.12 | 10195.12 | 1.79 | False | None | None | False | None | False | 18249.2648 | 0 |
3937581 | 152195 | None | 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
| Tonne | 94869.15 | 94869.15 | 5.43 | False | None | None | False | None | False | 515139.4845 | 0 |
3937582 | 152195 | None | 6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of
work"
| Cum | 8451.12 | 8451.12 | 54.93 | False | None | None | False | None | False | 464220.0216 | 0 |
3937583 | 152195 | None | 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
| Kg | 178.16 | 178.16 | 283.5 | False | None | None | False | None | False | 50508.36 | 0 |
3937584 | 152195 | None | 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside)
| Sqm | 330.88 | 330.88 | 201.71 | False | None | None | False | None | False | 66741.8048 | 0 |
3937585 | 152195 | None | 8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement:3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 388.14 | 388.14 | 217.24 | False | None | None | False | None | False | 84319.5336 | 0 |
3937586 | 152195 | None | 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 106.05 | 106.05 | 418.95 | False | None | None | False | None | False | 44429.6475 | 0 |
3937587 | 152195 | None | 8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and emoving scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 408.29 | 408.29 | 283.15 | False | None | None | False | None | False | 115607.3135 | 0 |
3937588 | 152195 | None | 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.
| Rmtr | 55.15 | 55.15 | 204.9 | False | None | None | False | None | False | 11300.235 | 0 |
3937589 | 152195 | None | 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 134.68 | 134.68 | 418.95 | False | None | None | False | None | False | 56424.186 | 0 |
3937590 | 152195 | None | 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 165.44 | 165.44 | 451.45 | False | None | None | False | None | False | 74687.888 | 0 |
3937591 | 152195 | None | 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 53.03 | 53.03 | 13.5 | False | None | None | False | None | False | 715.905 | 0 |
3937592 | 152195 | None | 8.4 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 121.96 | 121.96 | 13.5 | False | None | None | False | None | False | 1646.46 | 0 |
3937593 | 152195 | None | 4.21 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. 18-19 SR
| Rmtr | 36.0 | 36.0 | 18.6 | False | None | None | False | None | False | 669.6 | 0 |
3937594 | 152195 | None | 12.88 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 5716.1 | 5716.1 | 13.5 | False | None | None | False | None | False | 77167.35 | 0 |
3937595 | 152195 | None | 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.
| Sqm | 375.42 | 375.42 | 13.2 | False | None | None | False | None | False | 4955.544 | 0 |
3937596 | 152195 | None | 7.18 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.
| Sqm | 2139.03 | 2139.03 | 13.1 | False | None | None | False | None | False | 28021.293 | 0 |
3937597 | 152195 | None | 2.1.6 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6620.7 | 6620.7 | 19.38 | False | None | None | False | None | False | 128309.166 | 0 |
3937598 | 152195 | None | 9.3 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
| Sqm | 5650.34 | 5650.34 | 13.76 | False | None | None | False | None | False | 77748.6784 | 0 |
3937599 | 152195 | None | 12.17 | Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)
| Sqm | 7513.64 | 7513.64 | 7.2 | False | None | None | False | None | False | 54098.208 | 0 |
3937600 | 152195 | None | 12.11 | Providing Honne wood frames of doors, windows, clerestory windows,ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps),but including cost of materials, labour, usage charges complete as per specifications.
| Sqm | 146427.48 | 146427.48 | 0.32 | False | None | None | False | None | False | 46856.7936 | 0 |
3937601 | 152195 | None | 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
| No | 1077.47 | 1077.47 | 2.0 | False | None | None | False | None | False | 2154.94 | 0 |
3937602 | 152195 | None | 22.15.2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm
| No | 583.28 | 583.28 | 4.0 | False | None | None | False | None | False | 2333.12 | 0 |
3937603 | 152195 | None | 22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm
| No | 397.69 | 397.69 | 2.0 | False | None | None | False | None | False | 795.38 | 0 |
3937604 | 152195 | None | 22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm
| No | 159.08 | 159.08 | 4.0 | False | None | None | False | None | False | 636.32 | 0 |
3937605 | 152195 | None | 22.15.9 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm
| No | 74.24 | 74.24 | 8.0 | False | None | None | False | None | False | 593.92 | 0 |
3937606 | 152195 | None | 22.15.10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm
| No | 106.05 | 106.05 | 2.0 | False | None | None | False | None | False | 212.1 | 0 |
3937607 | 152195 | None | 12.6 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
| No | 1115.65 | 1115.65 | 2.0 | False | None | None | False | None | False | 2231.3 | 0 |
3937608 | 152195 | None | 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm
| No | 63.63 | 63.63 | 12.0 | False | None | None | False | None | False | 763.56 | 0 |
3937609 | 152195 | None | 20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.
| Rmtr | 55.15 | 55.15 | 12.6 | False | None | None | False | None | False | 694.89 | 0 |
3937610 | 152195 | None | 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 56.21 | 56.21 | 17.28 | False | None | None | False | None | False | 971.3088 | 0 |
3937611 | 152195 | None | 8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) | Sqm | 717.96 | 717.96 | 17.28 | False | None | None | False | None | False | 12406.3488 | 0 |
3937612 | 152195 | None | 9.17.2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
| Sqm | 1246.09 | 1246.09 | 103.57 | False | None | None | False | None | False | 129057.5413 | 0 |
3937613 | 152195 | None | 9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rub- bing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent."
| Sqm | 2615.19 | 2615.19 | 27.92 | False | None | None | False | None | False | 73016.1048 | 0 |
3937614 | 152195 | None | 15.11 | Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface like Roof, bathroom, toilet, balcony & utility area applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break 120% as per ASTM D 412, Tensile strength 1N/mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. | Sqm | 556.76 | 556.76 | 143.7 | False | None | None | False | None | False | 80006.412 | 0 |
3937615 | 152195 | None | 19.7.1 | Demolishing brick work manually/ by mechanical means including stack- ing of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.
| Cum | 511.16 | 511.16 | 11.79 | False | None | None | False | None | False | 6026.5764 | 0 |
3937616 | 152195 | None | 19.3 | Demolishing R.C.C. work manually/ by mechanical means including stack- ing of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.
| Cum | 2572.77 | 2572.77 | 1.89 | False | None | None | False | None | False | 4862.5353 | 0 |
3937617 | 152195 | None | 19.61 | Dismantling weather proof course and removing and conveying the debris to a distance to the appropriate disposal area as per direction of Engineer-in-charge.
| Cum | 610.85 | 610.85 | 8.73 | False | None | None | False | None | False | 5332.7205 | 0 |
3937618 | 152195 | None | 1.1A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum.
| Cum | 143.17 | 143.17 | 22.4 | False | None | None | False | None | False | 3207.008 | 0 |
3937619 | 152195 | None | 8.56.1 | White washing with lime to give an even shade :Old work (two coats) as per specifications and as per directions of Engineer in charge.
| Sqm | 15.91 | 15.91 | 184.5 | False | None | None | False | None | False | 2935.395 | 0 |
3937620 | 152195 | None | 8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.
| Sqm | 116.66 | 116.66 | 184.5 | False | None | None | False | None | False | 21523.77 | 0 |
3937621 | 152195 | None | 8.75.1 | Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (Two coats applied @ 1.43 l/ 10 m²) over existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 117.72 | 117.72 | 184.5 | False | None | None | False | None | False | 21719.34 | 0 |
3937622 | 152195 | None | 7.32.1 | and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 g/m2 (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per anufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095-(Part I) : 2011 (Board with BIS Certification marks only)
| Sqm | 1042.47 | 1042.47 | 97.5 | False | None | None | False | None | False | 101640.825 | 0 |
3937623 | 152195 | None | 7.32.3 | and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 g/m2 (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per anufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with12.5 mm thick tapered edge gypsum moisture resistant board
| Sqm | 1215.33 | 1215.33 | 20.0 | False | None | None | False | None | False | 24306.6 | 0 |
3937624 | 152195 | None | 1.2.1 | Mains Pipe.
Supplying heavy gauge PVC conduit pipe . mm dia.mm
thick confirming to IS 2509 with suitable size bends, metal/PVC
Junction boxes, adhesive paste etc., and running before concreting
the slab. The conduit should be tied to the reinforcement rods by
using binding wires and unused ways of junction boxes and pipe
ends should be covered using PVC end enclosures, run with
18SWG GI fish wire wherever necessary 1.2.1) 19/20 mm dia 2 mm thick Basic Rate -66=00 Wtg 5% - 3=30 Total - 69=30 PWD Ele SR 2023-24 Page No.1 Item code 1.2.1
| Rmtr | 69.3 | 69.3 | 175.0 | False | None | None | False | None | False | 12127.5 | 0 |
3937625 | 152195 | None | 2.2.1 | Points
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase &
Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC
insulated copper wire (confirming to IS-694: and latest
amendments) without control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be
terminated with sufficient loose length in a wood/PVC round block.
complete for each outlet.
2.2.1) Short point upto 3Mtr from tapping point to out let via switch box
Basic Rate -269=00 Wtg 5% - 13=45 Total - 282=45 PWD Ele SR 2023-24 Page No.4 Item code 2.2.1
| Point | 282.45 | 282.45 | 6.0 | False | None | None | False | None | False | 1694.7 | 0 |
3937626 | 152195 | None | 2.2.2 | Points
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase &
Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC
insulated copper wire (confirming to IS-694: and latest
amendments) without control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be
terminated with sufficient loose length in a wood/PVC round block.
complete for each outlet.
2.2.2) Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch box
Basic Rate -379=00 Wtg 5% - 18=95 Total - 397=45 PWD Ele SR 2023-24 Page No.4 Item code 2.2.2
| Point | 361.0 | 361.0 | 21.0 | False | None | None | False | None | False | 7581.0 | 0 |
3937627 | 152195 | None | 2.2.3 | Points
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase &
Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC
insulated copper wire (confirming to IS-694: and latest
amendments) without control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be
terminated with sufficient loose length in a wood/PVC round block.
complete for each outlet.
2.2.3) Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box
Basic Rate -555=00 Wtg 5% - 27=75 Total - 582=75 PWD Ele SR 2023-24 Page No.4 Item code 2.2.3
| Point | 361.0 | 361.0 | 8.0 | False | None | None | False | None | False | 2888.0 | 0 |
3937628 | 152195 | None | 2.3.2 | Wire:
Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS-
694:2010
2.3.2) 1.5 mm2
Basic Rate - 26=00 Wtg 5% - 1=30 Total - 27=30 PWD Ele SR 2023-24 Page No.4 Item code 2.3.2
| Rmtr | 27.3 | 27.3 | 80.0 | False | None | None | False | None | False | 2184.0 | 0 |
3937629 | 152195 | None | 2.3.2 | Wire:
Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS-
694:2010
2.3.3)2.5 mm2
Basic Rate - 42=00 Wtg 5% - 2=10 Total - 44=10 PWD Ele SR 2023-24 Page No.4 Item code 2.3.2 "
| Rmtr | 44.1 | 44.1 | 160.0 | False | None | None | False | None | False | 7056.0 | 0 |
3937630 | 152195 | None | 3.4.6 | Metal modular box:
Supplying and flush mounting powder coated / galvanized metal
box suitable for mounting modular switch plates. The box should be
firmly flush mounted after due groove cutting in Brick/Stone/C.C
wall 3.4.6)10-12Way
Basic Rate - 319=00 Wtg 5% - 15=95 Total - 334=95 PWD Ele SR 2023-24 Page No.7 Item code 3.4.6"
| No | 334.95 | 334.95 | 4.0 | False | None | None | False | None | False | 1339.8 | 0 |
3937631 | 152195 | None | 3.4.7 | Metal modular box:
Supplying and flush mounting powder coated / galvanized metal
box suitable for mounting modular switch plates. The box should be
firmly flush mounted after due groove cutting in Brick/Stone/C.C
wall 3.4.7)16Way
Basic Rate - 363=00 Wtg 5% - 18=15 Total - 381=15 PWD Ele SR 2023-24 Page No.7 Item code 3.4.7 "
| No | 334.95 | 334.95 | 2.0 | False | None | None | False | None | False | 669.9 | 0 |
3937632 | 152195 | None | 3.5.6 | modular Switch Plate
Supplying and fixing superior quality modular switch mounting
polycarbonate plate with necessary supporting back plate with
required nos. of machine screws, bolts nuts etc., complete on the
existing metal/PVC box. 3.5.6)10 -12 Module
Basic Rate - 344=00 Wtg 5% - 17=20 Total - 361=20 PWD Ele SR 2023-24 Page No.7 Item code 3.5.6 "
| No | 363.0 | 363.0 | 4.0 | False | None | None | False | None | False | 1452.0 | 0 |
3937633 | 152195 | None | 3.5.7 | modular Switch Plate
Supplying and fixing superior quality modular switch mounting
polycarbonate plate with necessary supporting back plate with
required nos. of machine screws, bolts nuts etc., complete on the
existing metal/PVC box. 3.5.7)16 Module
Basic Rate - 397=00 Wtg 5% - 19=85 Total - 416=85 PWD Ele SR 2023-24 Page No.7 Item code 3.5.7 "
| No | 363.0 | 363.0 | 2.0 | False | None | None | False | None | False | 726.0 | 0 |
3937634 | 152195 | None | 3.6.1 | Modular switch
Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. 3.6.1)6Amps one way.
Basic Rate - 102=00 Wtg 5% - 6=10 Total - 107=10 PWD Ele SR 2023-24 Page No.8 Item code 3.6.1"
| No | 88.0 | 88.0 | 40.0 | False | None | None | False | None | False | 3520.0 | 0 |
3937635 | 152195 | None | 3.6.2 | Modular socket
Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. 3.6.2)6A Two Way Switch Basic Rate - 166=00 Wtg 5% - 8=30 Total - 174=30 PWD Ele SR 2023-24 Page No.8 Item code 3.6.2"
| No | 174.3 | 174.3 | 6.0 | False | None | None | False | None | False | 1045.8 | 0 |
3937636 | 152195 | None | 3.6.4 | Stepped Fan Regulator.
Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. 3.6.4)Stepped Fan Regulator.
Basic Rate - 357=00 Wtg 5% - 17=85 Total - 374=85 PWD Ele SR 2023-24 Page No.8 Item code 3.6.4"
| No | 374.85 | 374.85 | 12.0 | False | None | None | False | None | False | 4498.2 | 0 |
3937637 | 152195 | None | 3.14.7 | Batten Holder
Supplying And fixing/replacing of 6/16/32A electrical
accessories on existing switch board. 3.14.7) 6A Batten Holder
Basic Rate - 74=00 Wtg 5% - 3=70 Total - 77=70 PWD Ele SR 2023-24 Page No.9 Item code 3.14.7"
| No | 77.7 | 77.7 | 35.0 | False | None | None | False | None | False | 2719.5 | 0 |
3937638 | 152195 | None | 11.3.2 | LED Tube Fitting
Supplying of .feet -PVC Batten with integrated LED tube . W
with high quality diffuser with Life of 25000 burning hours &
70% lumen maintenance with CRI 80. Power Input: 220-
240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2
years Warranty against any manufacturing defect working under
standard electrical condition.
11.3.2) LED light fighting 1 x4- 20/22 w
Basic Rate 724=00 Wtg 5% - 34=50 Total 724=50 PWD Ele SR 2023-24 Page No.42 Item code 11.3.2 | No | 724.5 | 724.5 | 22.0 | False | None | None | False | None | False | 15939.0 | 0 |
3937639 | 152195 | None | 13.7.1 | LED Fitting fixing Charges
Fixing all types and all capacities of fluorescent /false ceiling / spot
light / CFL / LED fittings indoor on the wall/ ceiling / rafters /
girders using 23/0.0076"" twin twisted PVC insulated wires,
required Nos of round blocks and clamps. 13.7.1).On wall/ ceiling / Rafter / Girders
Basic Rate - 122=00 Wtg 5% - 6=10 Total - 128=10 PWD Ele SR 2023-24 Page No.55 Item code 13.7.1
"
| No | 128.1 | 128.1 | 22.0 | False | None | None | False | None | False | 2818.2 | 0 |
3937640 | 152195 | None | 11.9.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm.
Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.8.2) LED Streetlight 40 watts Basic Rate 4024.00,ASL 5%-201.20. Total-4225.20 PWD | No | 4225.2 | 4225.2 | 1.0 | False | None | None | False | None | False | 4225.2 | 0 |
3937641 | 152195 | None | 13.5 | LED Fitting fixing Charges
Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over
existing pole / wall ceiling including clamps, bolts, nuts and wiring
using suitable capacity wires.
Basic Rate - 162=00 Wtg 5% - 8=10 Total - 170=10 PWD Ele SR 2023-24 Page No.55 Item code 13.5
"
| No | 170.1 | 170.1 | 22.0 | False | None | None | False | None | False | 3742.2 | 0 |
3937642 | 152195 | None | 13.1.1 | GI bracket Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. 13.1.1) Using 25mm dia G.I.Pipe Basic Rate - 978=00 ASL 5% - 48=90 Total - 1026=90 PWD Ele SR 2023-24 Page No.55 Item code 13.1.1
| No | 1026.9 | 1026.9 | 1.0 | False | None | None | False | None | False | 1026.9 | 0 |
3937643 | 152195 | None | 6.3.1 | Fans 48”
Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single
phase AC supply conforming to ISS-374- 1979 and with double
ball bearing system. 6.3.1) 48"" Sweep (1200mm) Regular model
Basic Rate - 2984=00 Wtg 5% - 149=20 Total - 3133=20 PWD Ele SR 2023-24 Page No.55 Item code 6.3.1"
| No | 3133.2 | 3133.2 | 12.0 | False | None | None | False | None | False | 37598.4 | 0 |
3937644 | 152195 | None | 6.3.1 | Fan Fixing Charges Fixing a ceiling /wall mounting fan of all capacities and all types,
with necessary clamps and 'S' hook made out of 15mm dia MS rod,
with 5 A. ceiling rose of approved quality with necessary length of
23/0.0076 inch PVC insulated twin twisted wire of approved
quality, mounted on a suitable size wooden board and wired. Basic Rate - 315=00 Wtg 5% - 15=75 Total - 330=75 PWD Ele SR 2023-24 Page No.56 Item code 6.3.1"
| No | 330.75 | 330.75 | 12.0 | False | None | None | False | None | False | 3969.0 | 0 |
3937645 | 152195 | None | 5.7.2 | Fuses
Supplying & fixing of Porcelain fuse channel with cut out on
existing wooden/panel using necessary nuts, bolts and washers. 5.7.2)32 A
Basic Rate - 241=00 Wtg 5% - 12=05 Total - 253=55 PWD Ele SR 2023-24 Page No.56 Item code 5.7.2"
| No | 253.05 | 253.05 | 1.0 | False | None | None | False | None | False | 253.05 | 0 |
3937646 | 152195 | None | 5.6.1 | Wood board
Supply and fixing polished wood board made of not less than
15mm thick plank on both sides of not more than 2 pieces and
fixing the same to the wall using tapered inverted wooden plugs
screws. 5.6.1) 8"" x 6"" x 1.5""
Basic Rate - 87=00 Wtg 5% - 4=35 Total - 91=35 PWD Ele SR 2023-24 Page No.13 Item code 5.6.1"
| No | 91.35 | 91.35 | 1.0 | False | None | None | False | None | False | 91.35 | 0 |
3937647 | 152195 | None | 5.18.4 | MCB Switches.
Supplying & fixing miniature circuit breakers on existing MCB
distribution boards using necessary fixing materials and 'C' Type
curve, indicator ON/OFF, energy cross-3 with Short circuit
breaking capacity of 10K and complete wiring as required
confirming to IEC 60898.
5.18.4) 6-32 Amps DP
Basic Rate - 739=00 Wtg 5% - 36=55 Total - 775=95 PWD Ele SR 2023-24 Page No.56 Item code 5.18.4"
| No | 775.95 | 775.95 | 3.0 | False | None | None | False | None | False | 2327.85 | 0 |
3937648 | 152195 | None | 5.19.8 | MCB distribution boards
Supplying and fixing regular MCB distribution boards on wall/ood
board / flush mounting using required clamps, bolts, nuts etc., with
provision for fixing suitable type capacity MCB's single phase/3
phase/single door with powder coated painting Made out of 14
SWG MS enclosure.
I - Single Door 5.19.1) 4 Way SP & N
Basic Rate - 1241=00 Wtg 5% - 62=05 Total - 1303=05 PWD Ele SR 2023-24 Page No.56 Item code 5.19.8"
| No | 1303.05 | 1303.05 | 1.0 | False | None | None | False | None | False | 1303.05 | 0 |
3937649 | 152195 | None | 5.42.2 | MS Box Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements,with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc.,complete. 5.42.2) 16SWG Basic Rate - 00=43 ,ASL 5% - 00=0215 Total - 00=4515 PWD Ele SR 2023-24 Page No.19 Item code 5.42.2
| Sq CM | 0.45 | 0.45 | 5550.0 | False | None | None | False | None | False | 2497.5 | 0 |
3937650 | 152195 | None | 25a | Earthing 25.a) GI Grounding pipe, B - Class, 42 mm dia, 2.5 M long, 3.2 mm thick with bolts nuts, GI Strips and washers complete
25.a) Transformer grounding Basic Rate - 1729=00 ASL 5% - 86=45 Total - 1815=45 Hescom SR 2023-24 Item code 25.a (Material Cost) "
| No | 1815.45 | 1815.45 | 1.0 | False | None | None | False | None | False | 1815.45 | 0 |
3937651 | 152195 | None | 25a | Earthing 25.a) GI Grounding pipe, B - Class, 42 mm dia, 2.5 M long, 3.2 mm thick with bolts nuts, GI Strips and washers complete
25.a) Transformer grounding Basic Rate - 949=00 ASL 5% - 47=45 Total - 996=45 Hescom SR 2023-24 Item code 25.a (Labour Cost) "
| No | 996.45 | 996.45 | 1.0 | False | None | None | False | None | False | 996.45 | 0 |