tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1727520076000 | 0 | None | None | Buildings | CONSTRUCTION OF OFFICE/GODOWN BUILDING OF PRIMERY AGREECULTURE COLLABRATIVE ASSOCIATION NI SHIRAGAONWADI IN CHIKKODI TALUKA | 807224.16 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4101303 | 159791 | None | code01 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge..(PWDSR 2023-24 Vol-2 P.No.50 I.No.8.51) | Sqm | 105.0 | 105.0 | 181.63 | False | None | None | False | None | False | 19071.15 | 0 | 4101304 | 159791 | None | code02 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge (PWDSR 2023-24 Vol-2 P.No.45 I.No.8.29) | Sqm | 297.15 | 297.15 | 566.57 | False | None | None | False | None | False | 168356.2755 | 0 | 4101305 | 159791 | None | code03 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge.(PWDSR 2023-24 Vol-2 P.No.45 I.No.8.25) | Sqm | 105.0 | 105.0 | 181.63 | False | None | None | False | None | False | 19071.15 | 0 | 4101306 | 159791 | None | code04 | Providing and laying Polished Glazed Vitrifed tiles in floor with different sizes (thickness to be specifed by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modifed quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600
mm | Sqm | 1299.9 | 1299.9 | 60.99 | False | None | None | False | None | False | 79280.901 | 0 | 4101307 | 159791 | None | code05 | Providing and fxing glazed screen printed border tile 75mm wide having thickness 5mm, of approved quality & make, in all shades, design and prints, in dado, over 12mm thick bed of cement mortar 1:3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3 kg/m2 including pointing with white cement mixed with pigment of matching shade, all complete as approved by Engineer - in - Charge.(PWDSR 2023-24 Vol-2 P.No.61 I.No.9.18) | Mtr | 142.8 | 142.8 | 61.03 | False | None | None | False | None | False | 8715.084 | 0 | 4101308 | 159791 | None | code06 | Providing Flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab including cost of materials, labour, curing, polishing complete as per specifcations | Sqm | 1732.5 | 1732.5 | 10.8 | False | None | None | False | None | False | 18711.0 | 0 | 4101309 | 159791 | None | code07 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specifed and as directed by the Engineer-in-Charge.Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.(PWDSR 2023-24 Vol-2 P.No.63 I.No.9.24) | Sqm | 2994.6 | 2994.6 | 62.5 | False | None | None | False | None | False | 187162.5 | 0 | 4101310 | 159791 | None | code08 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on Existing Roof surface//Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. (PWDSR 2021-22 Vol-2 P.No.133.I.No.15.2) | Sqm | 603.75 | 603.75 | 94.65 | False | None | None | False | None | False | 57144.9375 | 0 | 4101311 | 159791 | None | code09 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 g/m2 (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mmcentre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, | Sqm | 1099.0 | 1099.0 | 45.54 | False | None | None | False | None | False | 50048.46 | 0 | 4101312 | 159791 | None | code10 | Providing & fixing of 2-track x 2panel sliding windows made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profle throughout the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fxing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fxtures and separate charges for minor T&P's shall not be made)(PWDSR 2023-24 Vol-2 P.No.110 I.No.12.84) | Sqm | 1088.85 | 1088.85 | 7.92 | False | None | None | False | None | False | 8623.692 | 0 | 4101313 | 159791 | None | code11 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (Made of G.I. wire of dia 4 mm) (PWDSR 2023-24 Vol-2 P.No.95 I.No.11.58) | Sqm | 843.15 | 843.15 | 8.52 | False | None | None | False | None | False | 7183.638 | 0 | 4101314 | 159791 | None | code12 | Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challenged (PWDSR 2023-24 Vol-2 P.No.83 I.No.11.28) | Kg | 593.25 | 593.25 | 116.5 | False | None | None | False | None | False | 69113.625 | 0 | 4101315 | 159791 | None | code13 | Providing Sal wood wrought and putup for purlins, common rafters and similar work including cost of materials, labour, usage charges complete as per specifications(PWDSR 2023-24 Vol-2 P.No.99 I.No.12.4) --do-- Sal wood frames. | Cum | 101862.6 | 101862.6 | 0.349 | False | None | None | False | None | False | 35550.0474 | 0 | 4101316 | 159791 | None | code14 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifcations.(PWDSR 2023-24 Vol-2 P.No.105I.No.12.51) | Nos | 1066.8 | 1066.8 | 3.0 | False | None | None | False | None | False | 3200.4 | 0 | 4101317 | 159791 | None | code15 | Providing and fxing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifcations. (excluding cost of fxtures)(PWDSR 2023-24 Vol-2 P.No.100 I.No.12.15) | Sqm | 7241.85 | 7241.85 | 6.3 | False | None | None | False | None | False | 45623.655 | 0 | 4101318 | 159791 | None | code16 | Providing and fixing factory made Kitchen Cabinet Shutter/Partition 20 mmnominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 kg/m3 and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fixed to frame using approved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge. (PWD SR /2023-24/Vol-2/P.No 71 /I No 10.17) | Sqm | 4353.3 | 4353.3 | 4.56 | False | None | None | False | None | False | 19851.048 | 0 | 4101319 | 159791 | None | code17 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge.(PWDSR 2021-22 Vol-2 P.No.46 I.No.8.33.2) | Sqm | 144.9 | 144.9 | 29.1 | False | None | None | False | None | False | 4216.59 | 0 | 4101320 | 159791 | None | code18 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per pecifications and as per directions of Engineer-in-charge..(PWDSR 2023-24 Vol-2 P.No.49 I.No.8.49) | Cum | 4.2 | 4.2 | 1500.0 | False | None | None | False | None | False | 6300.0 | 0 |
| 1727520076000 | 0 | None | None | Buildings | eletrification | 36432.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4101321 | 159792 | None | code01 | Supplying 6A flush type socket and 6 A flush type SP switcheither surface/flush mounting in existing gang box or in 4mmthick plastic sheet and fixing over a flush mounted wooden boxand wiring using necessary capacity wires as required as per IS1293 and IS 3654 3.1.2 6A 3/5 Way ELECRIC SR P NO 5 | Nos | 143.0 | 143.0 | 5.0 | False | None | None | False | None | False | 715.0 | 0 | 4101322 | 159792 | None | code02 | Supplying and fixing superior quality modular switch mountingpolycarbonate plate with necessary supporting back plate withrequired nos. of machine screws, bolts nuts etc., complete onthe existing metal/PVC box. 3.5.2 4 Module | Nos | 175.0 | 175.0 | 5.0 | False | None | None | False | None | False | 875.0 | 0 | 4101323 | 159792 | None | code03 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. 1.6.1 12"x12"x3" (300x300x76mm) | Each | 112.0 | 112.0 | 5.0 | False | None | None | False | None | False | 560.0 | 0 | 4101324 | 159792 | None | code04 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.3.2 1.5 sqmm | Mtr | 26.0 | 26.0 | 110.0 | False | None | None | False | None | False | 2860.0 | 0 | 4101325 | 159792 | None | code05 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.3.2 2.5 | Mtr | 40.0 | 40.0 | 250.0 | False | None | None | False | None | False | 10000.0 | 0 | 4101326 | 159792 | None | code06 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300mm …. etc. as required. Ino 1.8.3 32 mm p no 2 | Mtr | 41.0 | 41.0 | 110.0 | False | None | None | False | None | False | 4510.0 | 0 | 4101327 | 159792 | None | code07 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF,energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. | Nos | 1376.0 | 1376.0 | 2.0 | False | None | None | False | None | False | 2752.0 | 0 | 4101328 | 159792 | None | code08 | Supplying & fixing retrofit typePL LED Lamp 8-9 W W LEDlinear source with CCT 6500 degree K, CRI 70%. efficacy80 lumen per W, 25000 burning hours andCompliance to IS 10322/IEC 60598, LM 79 & LM 80.The LED are driven by HF electronic driver integrated in thesystem, with PF 0.95, power loss should 5% of lampWage., short circuit & open circuit protection to be integratedin the circuit, THD less than 20%, Life as per LM 79. Theoperating input voltage should be between 130 to275 V.Tested by NABL/CPRI accredited laboratory with 2 yearsWarranty against any manufacturing defect working understandard electrical condition. 11.2.1 8-9 W | Nos | 613.0 | 613.0 | 12.0 | False | None | None | False | None | False | 7356.0 | 0 | 4101329 | 159792 | None | code09 | Point wiring using Copper wire with switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using copper PVC insulated multi strand 2x1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (2.1) I. Point wiring using class A Materials b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Nos | 567.0 | 567.0 | 12.0 | False | None | None | False | None | False | 6804.0 | 0 |
|
|
---|