4094316 | 159457 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m . | Cum | 102.0 | 102.0 | 595.98 | False | None | None | False | None | False | 60789.96 | 0 |
4094317 | 159457 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 363.0 | 363.0 | 230.94 | False | None | None | False | None | False | 83831.22 | 0 |
4094318 | 159457 | None | code03 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm hickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 2682.0 | 2682.0 | 93.738 | False | None | None | False | None | False | 251405.316 | 0 |
4094319 | 159457 | None | code04 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6789.96 | 6789.96 | 199.607 | False | None | None | False | None | False | 1355323.54572 | 0 |
4094320 | 159457 | None | code05 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. for Drain Wall | Cum | 8487.45 | 8487.45 | 10.19 | False | None | None | False | None | False | 86487.1155 | 0 |
4094321 | 159457 | None | code06 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. for Retaining Wall | Cum | 6915.7 | 6915.7 | 22.212 | False | None | None | False | None | False | 153611.5284 | 0 |
4094322 | 159457 | None | code07 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Column | Cum | 10687.9 | 10687.9 | 5.98 | False | None | None | False | None | False | 63913.642 | 0 |
4094323 | 159457 | None | code08 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Drain Wall | Cum | 8487.45 | 8487.45 | 10.19 | False | None | None | False | None | False | 86487.1155 | 0 |
4094324 | 159457 | None | code09 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Beam | Cum | 10059.2 | 10059.2 | 26.142 | False | None | None | False | None | False | 262967.6064 | 0 |
4094325 | 159457 | None | code10 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1310.0 | 1310.0 | 152.923 | False | None | None | False | None | False | 200329.13 | 0 |
4094326 | 159457 | None | code11 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Column | Cum | 11271.0 | 11271.0 | 27.479 | False | None | None | False | None | False | 309715.809 | 0 |
4094327 | 159457 | None | code12 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Lintel | Cum | 10608.0 | 10608.0 | 2.121 | False | None | None | False | None | False | 22499.568 | 0 |
4094328 | 159457 | None | code13 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Slab | Cum | 9945.0 | 9945.0 | 95.833 | False | None | None | False | None | False | 953059.185 | 0 |
4094329 | 159457 | None | code14 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Beam | Cum | 10608.0 | 10608.0 | 47.465 | False | None | None | False | None | False | 503508.72 | 0 |
4094330 | 159457 | None | code15 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Staircase | Cum | 9945.0 | 9945.0 | 22.531 | False | None | None | False | None | False | 224070.795 | 0 |
4094331 | 159457 | None | code16 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 89457.0 | 89457.0 | 37.977 | False | None | None | False | None | False | 3397308.489 | 0 |
4094332 | 159457 | None | code17 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cementn: 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8874.0 | 8874.0 | 0.27 | False | None | None | False | None | False | 2395.98 | 0 |
4094333 | 159457 | None | code18 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Cum | 241.0 | 241.0 | 617.1 | False | None | None | False | None | False | 148721.1 | 0 |
4094334 | 159457 | None | code19 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 211.0 | 211.0 | 210.841 | False | None | None | False | None | False | 44487.451 | 0 |
4094335 | 159457 | None | code20 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 53.0 | 53.0 | 604.081 | False | None | None | False | None | False | 32016.293 | 0 |
4094336 | 159457 | None | code21 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 89.0 | 89.0 | 604.081 | False | None | None | False | None | False | 53763.209 | 0 |
4094337 | 159457 | None | code22 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge | Sqm | 100.0 | 100.0 | 195.12 | False | None | None | False | None | False | 19512.0 | 0 |
4094338 | 159457 | None | code23 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 137.0 | 137.0 | 282.81 | False | None | None | False | None | False | 38744.97 | 0 |
4094339 | 159457 | None | code24 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. | Sqm | 2466.0 | 2466.0 | 89.07 | False | None | None | False | None | False | 219646.62 | 0 |
4094340 | 159457 | None | code25 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm | Sqm | 1326.0 | 1326.0 | 87.691 | False | None | None | False | None | False | 116278.266 | 0 |
4094341 | 159457 | None | code26 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 168.0 | 168.0 | 3174.3286 | False | None | None | False | None | False | 533287.2048 | 0 |
4094342 | 159457 | None | code27 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 6734.0 | 6734.0 | 14.399 | False | None | None | False | None | False | 96962.866 | 0 |
4094343 | 159457 | None | code28 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. | Kg | 136.0 | 136.0 | 2178.934 | False | None | None | False | None | False | 296335.024 | 0 |
4094344 | 159457 | None | code29 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 8276.0 | 8276.0 | 9.6 | False | None | None | False | None | False | 79449.6 | 0 |
4094345 | 159457 | None | code30 | Providing and fixing M.S. angle 50x50x5 mm to act as nosing with lugs of M.S. flat 10x5 mm, 10 cm long, forked at end 60cm apart (minimum three lugs to be provided), including necessary welding and applying a priming coat of approved primer on exposed surface etc. complete. | Kg | 140.0 | 140.0 | 132.012 | False | None | None | False | None | False | 18481.68 | 0 |
4094346 | 159457 | None | code31 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 139.0 | 139.0 | 101.75 | False | None | None | False | None | False | 14143.25 | 0 |
4094347 | 159457 | None | code32 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter | m | 197.0 | 197.0 | 70.0 | False | None | None | False | None | False | 13790.0 | 0 |
4094348 | 159457 | None | code33 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 75 mm dia PVC Tee | Each | 117.0 | 117.0 | 15.0 | False | None | None | False | None | False | 1755.0 | 0 |
4094349 | 159457 | None | code34 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments. 75 mm dia PVC Elbows | Each | 192.0 | 192.0 | 15.0 | False | None | None | False | None | False | 2880.0 | 0 |
4094350 | 159457 | None | code35 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1310.0 | 1310.0 | 73.0489 | False | None | None | False | None | False | 95694.059 | 0 |
4094351 | 159457 | None | code36 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Column | Cum | 11271.0 | 11271.0 | 29.808 | False | None | None | False | None | False | 335965.968 | 0 |
4094352 | 159457 | None | code37 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Lintel | Cum | 10608.0 | 10608.0 | 5.086 | False | None | None | False | None | False | 53952.288 | 0 |
4094353 | 159457 | None | code38 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Slab | Cum | 9945.0 | 9945.0 | 94.447 | False | None | None | False | None | False | 939275.415 | 0 |
4094354 | 159457 | None | code39 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Beam | Cum | 10608.0 | 10608.0 | 40.239 | False | None | None | False | None | False | 426855.312 | 0 |
4094355 | 159457 | None | code40 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Staircase | Cum | 9945.0 | 9945.0 | 7.495 | False | None | None | False | None | False | 74537.775 | 0 |
4094356 | 159457 | None | code41 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 89457.0 | 89457.0 | 14.166 | False | None | None | False | None | False | 1267247.862 | 0 |
4094357 | 159457 | None | code42 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 241.0 | 241.0 | 1183.406 | False | None | None | False | None | False | 285200.846 | 0 |
4094358 | 159457 | None | code43 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 211.0 | 211.0 | 596.619 | False | None | None | False | None | False | 125886.609 | 0 |
4094359 | 159457 | None | code44 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 53.0 | 53.0 | 272.102 | False | None | None | False | None | False | 14421.406 | 0 |
4094360 | 159457 | None | code45 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 89.0 | 89.0 | 272.102 | False | None | None | False | None | False | 24217.078 | 0 |
4094361 | 159457 | None | code46 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge | Sqm | 100.0 | 100.0 | 911.304 | False | None | None | False | None | False | 91130.4 | 0 |
4094362 | 159457 | None | code47 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 137.0 | 137.0 | 1523.065 | False | None | None | False | None | False | 208659.905 | 0 |
4094363 | 159457 | None | code48 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. | Sqm | 2466.0 | 2466.0 | 426.608 | False | None | None | False | None | False | 1052015.328 | 0 |
4094364 | 159457 | None | code49 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm | Sqm | 1326.0 | 1326.0 | 291.75 | False | None | None | False | None | False | 386860.5 | 0 |
4094365 | 159457 | None | code50 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per
specifications. | Sqm | 1392.0 | 1392.0 | 8.412 | False | None | None | False | None | False | 11709.504 | 0 |
4094366 | 159457 | None | code51 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inharge. | Kg | 136.0 | 136.0 | 2058.0828 | False | None | None | False | None | False | 279899.2608 | 0 |
4094367 | 159457 | None | code52 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 8276.0 | 8276.0 | 307.08 | False | None | None | False | None | False | 2541394.08 | 0 |
4094368 | 159457 | None | code53 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 139.0 | 139.0 | 676.83 | False | None | None | False | None | False | 94079.37 | 0 |
4094369 | 159457 | None | code54 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m . | Cum | 102.0 | 102.0 | 20.863 | False | None | None | False | None | False | 2128.026 | 0 |
4094370 | 159457 | None | code55 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm hickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 2682.0 | 2682.0 | 1.272 | False | None | None | False | None | False | 3411.504 | 0 |
4094371 | 159457 | None | code56 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6789.96 | 6789.96 | 1.272 | False | None | None | False | None | False | 8636.82912 | 0 |
4094372 | 159457 | None | code57 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 10687.9 | 10687.9 | 1.272 | False | None | None | False | None | False | 13595.0088 | 0 |
4094373 | 159457 | None | code58 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 89457.0 | 89457.0 | 0.397 | False | None | None | False | None | False | 35514.429 | 0 |
4094374 | 159457 | None | code59 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to RCC structures like floor and walls of reservoirs, sewe, effluent and water treatment plants, over head tanks, etc. prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry 2 parts water) for horizontal and vertical surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI - 212-3R-2010 ie. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 Bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self healing of cracks upto a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the Engineer in charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal and vertical surfaces in two coats @ 0.70 kg per sqm per coat | Sqm | 433.0 | 433.0 | 28.2 | False | None | None | False | None | False | 12210.6 | 0 |
4094375 | 159457 | None | code60 | C.I. cover and frame 300x300 mm inside. | Each | 480.0 | 480.0 | 1.0 | False | None | None | False | None | False | 480.0 | 0 |
4094376 | 159457 | None | code61 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m . | Cum | 102.0 | 102.0 | 20.863 | False | None | None | False | None | False | 2128.026 | 0 |
4094377 | 159457 | None | code62 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm hickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 2682.0 | 2682.0 | 1.272 | False | None | None | False | None | False | 3411.504 | 0 |
4094378 | 159457 | None | code63 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6789.96 | 6789.96 | 1.272 | False | None | None | False | None | False | 8636.82912 | 0 |
4094379 | 159457 | None | code64 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 10687.9 | 10687.9 | 1.272 | False | None | None | False | None | False | 13595.0088 | 0 |
4094380 | 159457 | None | code65 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 89457.0 | 89457.0 | 0.397 | False | None | None | False | None | False | 35514.429 | 0 |
4094381 | 159457 | None | code66 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to RCC structures like floor and walls of reservoirs, sewe, effluent and water treatment plants, over head tanks, etc. prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry 2 parts water) for horizontal and vertical surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI - 212-3R-2010 ie. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 Bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self healing of cracks upto a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the Engineer in charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal and vertical surfaces in two coats @ 0.70 kg per sqm per coat | Sqm | 433.0 | 433.0 | 28.2 | False | None | None | False | None | False | 12210.6 | 0 |
4094382 | 159457 | None | code67 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete for: PVC pipes 160mm dia., 6 kg/sqcm & class 3 | m | 618.0 | 618.0 | 5.0 | False | None | None | False | None | False | 3090.0 | 0 |
4094383 | 159457 | None | code68 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete for: PVC pipes 160mm dia., 6 kg/sqcm & class 3 | m | 618.0 | 618.0 | 5.0 | False | None | None | False | None | False | 3090.0 | 0 |
4094384 | 159457 | None | code69 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 160 mm dia PVC Tee. | Each | 466.0 | 466.0 | 1.0 | False | None | None | False | None | False | 466.0 | 0 |
4094385 | 159457 | None | code70 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m . | Cum | 102.0 | 102.0 | 81.968 | False | None | None | False | None | False | 8360.736 | 0 |
4094386 | 159457 | None | code71 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm hickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 2682.0 | 2682.0 | 13.53 | False | None | None | False | None | False | 36287.46 | 0 |
4094387 | 159457 | None | code72 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 160.0 | 160.0 | 42.5632 | False | None | None | False | None | False | 6810.112 | 0 |
4094388 | 159457 | None | code73 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6287.0 | 6287.0 | 11.944 | False | None | None | False | None | False | 75091.928 | 0 |
4094389 | 159457 | None | code74 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6789.96 | 6789.96 | 5.5672 | False | None | None | False | None | False | 37801.065312 | 0 |
4094390 | 159457 | None | code75 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7293.0 | 7293.0 | 9.0298 | False | None | None | False | None | False | 65854.3314 | 0 |
4094391 | 159457 | None | code76 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 89457.0 | 89457.0 | 1.0947 | False | None | None | False | None | False | 97928.5779 | 0 |
4094392 | 159457 | None | code77 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 211.0 | 211.0 | 39.26 | False | None | None | False | None | False | 8283.86 | 0 |
4094393 | 159457 | None | code78 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 53.0 | 53.0 | 39.26 | False | None | None | False | None | False | 2080.78 | 0 |
4094394 | 159457 | None | code79 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 89.0 | 89.0 | 39.26 | False | None | None | False | None | False | 3494.14 | 0 |
4094395 | 159457 | None | code80 | Supplying heavy gauge PVC conduit pipe......mm dia..........mm thick confirming to IS2509 with suitable size bends,metal/PVC Junction boxes,adhesive past eetc.,and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with18 SWG GI fishwire wherever necessary. 40 mm dia 2.5 mm thick | m | 147.0 | 147.0 | 500.0 | False | None | None | False | None | False | 73500.0 | 0 |
4094396 | 159457 | None | code81 | Supplying And Fixing Metal Fan Box with Round Hook. Fan Box | Each | 117.0 | 117.0 | 30.0 | False | None | None | False | None | False | 3510.0 | 0 |
4094397 | 159457 | None | code82 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-2 Way | Each | 138.0 | 138.0 | 25.0 | False | None | None | False | None | False | 3450.0 | 0 |
4094398 | 159457 | None | code83 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6 Way | Each | 220.0 | 220.0 | 10.0 | False | None | None | False | None | False | 2200.0 | 0 |
4094399 | 159457 | None | code84 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 18 Way | Each | 405.0 | 405.0 | 30.0 | False | None | None | False | None | False | 12150.0 | 0 |
4094400 | 159457 | None | code85 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module | Each | 137.0 | 137.0 | 25.0 | False | None | None | False | None | False | 3425.0 | 0 |
4094401 | 159457 | None | code86 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 Module | Each | 234.0 | 234.0 | 10.0 | False | None | None | False | None | False | 2340.0 | 0 |
4094402 | 159457 | None | code87 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 18 Module | Each | 457.0 | 457.0 | 30.0 | False | None | None | False | None | False | 13710.0 | 0 |
4094403 | 159457 | None | code88 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A” materials. 6A one way switch | Each | 102.0 | 102.0 | 120.0 | False | None | None | False | None | False | 12240.0 | 0 |
4094404 | 159457 | None | code89 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A” materials. 6A Two way switch | Each | 166.0 | 166.0 | 60.0 | False | None | None | False | None | False | 9960.0 | 0 |
4094405 | 159457 | None | code90 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A” materials. Stepped fan regulator two module | Each | 357.0 | 357.0 | 30.0 | False | None | None | False | None | False | 10710.0 | 0 |
4094406 | 159457 | None | code91 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A” materials. 16A one way switch | Each | 180.0 | 180.0 | 60.0 | False | None | None | False | None | False | 10800.0 | 0 |
4094407 | 159457 | None | code92 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A” materials. 32A DP Switch | Each | 326.0 | 326.0 | 30.0 | False | None | None | False | None | False | 9780.0 | 0 |
4094408 | 159457 | None | code93 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A” materials. 6/16A Universal socket | Each | 236.0 | 236.0 | 60.0 | False | None | None | False | None | False | 14160.0 | 0 |
4094409 | 159457 | None | code94 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. LED Indicating Lamp | Each | 515.0 | 515.0 | 35.0 | False | None | None | False | None | False | 18025.0 | 0 |
4094410 | 159457 | None | code95 | LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal) (Dwg No. BESCOM/GM/QS&S/58 Dtd 24.11.2018). Distribution box 100 kVa | Each | 22686.0 | 22686.0 | 1.0 | False | None | None | False | None | False | 22686.0 | 0 |
4094411 | 159457 | None | code96 | Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and-CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired. Electronic Meter box | Each | 4390.0 | 4390.0 | 31.0 | False | None | None | False | None | False | 136090.0 | 0 |
4094412 | 159457 | None | code97 | Supplying of on load change over switches 4 poles,AC-23A Duty, 415V, 50Hz, AC Supply. (SMEnclosure Sheet Metal Execution) 200 A | Each | 15249.0 | 15249.0 | 1.0 | False | None | None | False | None | False | 15249.0 | 0 |
4094413 | 159457 | None | code98 | Installation of Insulation piercing connector for Main to Service Line Main: 25-95 Sqmm, Tap: 25-95 Sqmm (P3X95).200 A | Each | 128.0 | 128.0 | 4.0 | False | None | None | False | None | False | 512.0 | 0 |
4094414 | 159457 | None | code99 | Supplying and fixing PVC/metal conduit Deep junction box. 32 mm deep Junction box | Each | 61.0 | 61.0 | 60.0 | False | None | None | False | None | False | 3660.0 | 0 |
4094415 | 159457 | None | code100 | Supplying 4mm thick white plastic plate and covering for junction boxes of size ...... mmconduit using necessarymachine screws. 110 mm cover plates for deep junction boxes | Each | 21.0 | 21.0 | 60.0 | False | None | None | False | None | False | 1260.0 | 0 |
4094416 | 159457 | None | code101 | Supplying andfixing Moulded Case Circuit Breaker(MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete.Protection of Overload and Short circuit with adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs). In4PMCCB, all Poles should have protection for Short-Cicrcuit/OverLoad. ForMicroprocessorMCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. THREE Pole 200 A 25kA | Each | 14535.0 | 14535.0 | 5.0 | False | None | None | False | None | False | 72675.0 | 0 |
4094417 | 159457 | None | code102 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified. Rod type Earthing | Each | 2172.0 | 2172.0 | 1.0 | False | None | None | False | None | False | 2172.0 | 0 |
4094418 | 159457 | None | code103 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each HESCOM SR. Charcoal | Each | 676.0 | 676.0 | 1.0 | False | None | None | False | None | False | 676.0 | 0 |
4094419 | 159457 | None | code104 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag HESCOM SR. Salt | Each | 310.0 | 310.0 | 1.0 | False | None | None | False | None | False | 310.0 | 0 |
4094420 | 159457 | None | code105 | Digging of Pit for providing GI Pipe type Earthing LABOUR RATE HESCOM SR. Hard Soil Pit for Earthing | Each | 2990.0 | 2990.0 | 1.0 | False | None | None | False | None | False | 2990.0 | 0 |
4094421 | 159457 | None | code106 | Supplying and wiring adopting loop system in existing PVC Conduit /casing cappingcasing capping using 2x1.5 Sqmm (Phase&Neutral)
&1x1.0 sqmm (Earthwire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/ PVC round block. complete for each outlet. Using class A Materials. Short point upto 3Mtr from tapping point to out let via switch box | Each | 269.0 | 269.0 | 80.0 | False | None | None | False | None | False | 21520.0 | 0 |
4094422 | 159457 | None | code107 | Supplying and wiring adopting loop system in existing PVC Conduit /casing cappingcasing capping using 2x1.5 Sqmm (Phase&Neutral)
&1x1.0 sqmm (Earthwire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/ PVC round block. complete for each outlet. Using class A Materials.. Medium point above 3 Mtr upto 6 Mtr from tapping point to out let via switch box | Each | 379.0 | 379.0 | 70.0 | False | None | None | False | None | False | 26530.0 | 0 |
4094423 | 159457 | None | code108 | Supplying and wiring adopting loop system in existing PVC Conduit /casing cappingcasing capping using 2x1.5 Sqmm (Phase&Neutral)
&1x1.0 sqmm (Earthwire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/ PVC round block. complete for each outlet. Using class A Materials. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box | Each | 555.0 | 555.0 | 45.0 | False | None | None | False | None | False | 24975.0 | 0 |
4094424 | 159457 | None | code109 | Supplying and wiring adopting loop system in existing PVC Conduit /casing cappingcasing capping using 2x1.5 Sqmm (Phase&Neutral)
&1x1.0 sqmm (Earthwire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/ PVC round block. complete for each outlet. Using class A Materials. Two outlet in a row, above 3 Mtr upto 6 Mtr from tapping point to out let via switches | Each | 677.0 | 677.0 | 35.0 | False | None | None | False | None | False | 23695.0 | 0 |
4094425 | 159457 | None | code110 | Supplying and wiring adopting loop system in existing PVC Conduit /casing cappingcasing capping using 2x1.5 Sqmm (Phase&Neutral)
&1x1.0 sqmm (Earthwire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/ PVC round block. complete for each outlet. Using class A Materials. Threeoutlet inarow, above6Mtsupto10Mtr fromtappingpoint to
out let via switches box | Each | 989.0 | 989.0 | 25.0 | False | None | None | False | None | False | 24725.0 | 0 |
4094426 | 159457 | None | code111 | Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm | m | 26.0 | 26.0 | 605.0 | False | None | None | False | None | False | 15730.0 | 0 |
4094427 | 159457 | None | code112 | Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm | m | 42.0 | 42.0 | 400.0 | False | None | None | False | None | False | 16800.0 | 0 |
4094428 | 159457 | None | code113 | Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm | m | 63.0 | 63.0 | 290.0 | False | None | None | False | None | False | 18270.0 | 0 |
4094429 | 159457 | None | code114 | Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm | m | 92.0 | 92.0 | 250.0 | False | None | None | False | None | False | 23000.0 | 0 |
4094430 | 159457 | None | code115 | Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 10 sqmm | m | 167.0 | 167.0 | 150.0 | False | None | None | False | None | False | 25050.0 | 0 |
4094431 | 159457 | None | code116 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 50-63 A TPN | Each | 3088.0 | 3088.0 | 5.0 | False | None | None | False | None | False | 15440.0 | 0 |
4094432 | 159457 | None | code117 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB’s single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door. a) 4Way TP &N | Each | 4038.0 | 4038.0 | 1.0 | False | None | None | False | None | False | 4038.0 | 0 |
4094433 | 159457 | None | code118 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | No | 2172.0 | 2172.0 | 1.0 | False | None | None | False | None | False | 2172.0 | 0 |
4094434 | 159457 | None | code119 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each HESCOM SR | No | 676.0 | 676.0 | 1.0 | False | None | None | False | None | False | 676.0 | 0 |
4094435 | 159457 | None | code120 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag HESCOM SR | Each | 310.0 | 310.0 | 1.0 | False | None | None | False | None | False | 310.0 | 0 |
4094436 | 159457 | None | code121 | Digging of Pit for providing GI Pipe type Earthing LABOUR RATE HESCOM SR. Hard Soil | Each | 2990.0 | 2990.0 | 1.0 | False | None | None | False | None | False | 2990.0 | 0 |
4094437 | 159457 | None | code122 | Single phase, oil filled, outdoor type VT with terminal connector suitable for Al. tube conductor with marshalling box etc., complete as per technical specification, | No | 150040.0 | 150040.0 | 1.0 | False | None | None | False | None | False | 150040.0 | 0 |