createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1727515449881
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1690.00
emd160000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose08-10-2024 16:30:00
tenderQueryClose08-10-2024 15:30:00
technicalBidOpen09-10-2024 17:30:00
publishedDate30-09-2024 14:00:25
publishedByPostRDPR_EE_DIV_BLR
publishedByUserKPE19203 - H INDUDHAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEE PRE DIVISION BALLARI
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08392266173
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1727515449929
version4
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT9294
titleConstruction of Taluk Panchayath Building (Spillover work) at Kurugodu in Ballari Dist
descriptionConstruction of Taluk Panchayath Building (Spillover work) at Kurugodu in Ballari Dist
categoryWORKS
categoryTextWorks
ecv6752945.28
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location818
locationNameRDPR Division Office Ballari
provisionalAmount8000000.0
groupOverheadTotalNone
fileNumberEE/RDPR/2515/ZP/KURUGODU
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17275154500000NoneNoneBuildingsConstruction of Taluk Panchayath Building at Kurugodu (Spill over Work) in Ballari Dist6752945.28
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
4100717159777Nonecode01Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum99.7599.7513.5FalseNoneNoneFalseNoneFalse1346.6250
4100718159777Nonecode02Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/Sqm including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm123.9123.954.0FalseNoneNoneFalseNoneFalse6690.60
4100719159777Nonecode03Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum107.1107.116.2FalseNoneNoneFalseNoneFalse1735.020
4100720159777Nonecode04Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.4514.31FalseNoneNoneFalseNoneFalse89987.71950
4100721159777Nonecode05Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.313.48FalseNoneNoneFalseNoneFalse3764.9640
4100722159777Nonecode06Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6633.156633.152.25FalseNoneNoneFalseNoneFalse14924.58750
4100723159777Nonecode07Additionalities for Formwork, Centering andScaffolding for footingCum532.22532.222.25FalseNoneNoneFalseNoneFalse1197.4950
4100724159777Nonecode08Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6652.86652.80.47FalseNoneNoneFalseNoneFalse3126.8160
4100725159777Nonecode09Additionalities for Formwork, Centering andScaffolding 70% for ColumnsCum4656.964656.960.47FalseNoneNoneFalseNoneFalse2188.77120
4100726159777Nonecode10Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6804.06804.01.45FalseNoneNoneFalseNoneFalse9865.80
4100727159777Nonecode11Additionalities for Formwork, Centering andScaffolding 50% for Plinth beamCum3402.03402.01.45FalseNoneNoneFalseNoneFalse4932.90
4100728159777Nonecode12Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.150.95FalseNoneNoneFalseNoneFalse6825.89250
4100729159777Nonecode13Additionalities for Formwork, Centering andScaffolding 70% for ColumnsCum5029.615029.610.95FalseNoneNoneFalseNoneFalse4778.12950
4100730159777Nonecode14Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.152.17FalseNoneNoneFalseNoneFalse15591.77550
4100731159777Nonecode15Additionalities for Formwork, Centering andScaffolding 60% for Lintel beamCum4311.094311.092.17FalseNoneNoneFalseNoneFalse9355.06530
4100732159777Nonecode16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.158.42FalseNoneNoneFalseNoneFalse60498.9630
4100733159777Nonecode17Additionalities for Formwork, Centering andScaffolding 50% for Roof slab and Stair caseCum3592.583592.588.42FalseNoneNoneFalseNoneFalse30249.52360
4100734159777Nonecode18Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. BuildingsTonne93929.8593929.851.26FalseNoneNoneFalseNoneFalse118351.6110
4100735159777Nonecode19Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8367.458367.453.62FalseNoneNoneFalseNoneFalse30290.1690
4100736159777Nonecode20Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm404.25404.2536.33FalseNoneNoneFalseNoneFalse14686.40250
4100737159777Nonecode21Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm133.35133.351091.37FalseNoneNoneFalseNoneFalse145534.18950
4100738159777Nonecode22Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm182.7182.7279.56FalseNoneNoneFalseNoneFalse51075.6120
4100739159777Nonecode23Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm297.15297.1584.0FalseNoneNoneFalseNoneFalse24960.60
4100740159777Nonecode24Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm55.6555.6569.55FalseNoneNoneFalseNoneFalse3870.45750
4100741159777Nonecode25Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm144.9144.969.55FalseNoneNoneFalseNoneFalse10077.7950
4100742159777Nonecode26Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm120.75120.7565.16FalseNoneNoneFalseNoneFalse7868.070
4100743159777Nonecode27Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mmSqm1233.751233.7513.83FalseNoneNoneFalseNoneFalse17062.76250
4100744159777Nonecode28Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Sqm2189.252189.25153.89FalseNoneNoneFalseNoneFalse336903.68250
4100745159777Nonecode29Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.m344.4344.477.54FalseNoneNoneFalseNoneFalse26704.7760
4100746159777Nonecode30Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete.Sqm933.45933.4531.46FalseNoneNoneFalseNoneFalse29366.3370
4100747159777Nonecode31Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1461.61461.6114.14FalseNoneNoneFalseNoneFalse166827.0240
4100748159777Nonecode32Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg593.25593.25123.3FalseNoneNoneFalseNoneFalse73147.7250
4100749159777Nonecode33Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti- tions by cutting a chase of appropriate width with chase cutter and embed- ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.Sqm2928.452928.451.35FalseNoneNoneFalseNoneFalse3953.40750
4100750159777Nonecode34Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7257.07257.010.38FalseNoneNoneFalseNoneFalse75327.660
4100751159777Nonecode35Additionalities for formwork, Centering and Scaffolding 70% for ColumnsCum5079.95079.910.38FalseNoneNoneFalseNoneFalse52729.3620
4100752159777Nonecode36Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7257.07257.042.27FalseNoneNoneFalseNoneFalse306753.390
4100753159777Nonecode37Additionalities for formwork, Centering and Scaffolding 60% for Beam & LintelCum4354.24354.210.67FalseNoneNoneFalseNoneFalse46459.3140
4100754159777Nonecode38Additionalities for formwork, Centering and Scaffolding 50% for Roof Slab and StaircaseCum3628.53628.531.61FalseNoneNoneFalseNoneFalse114696.8850
4100755159777Nonecode39Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm0 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7031.127031.121.32FalseNoneNoneFalseNoneFalse9281.07840
4100756159777Nonecode40Additionalities for formwork, Centering and Scaffolding 45% for ChejjasCum3164.03164.01.32FalseNoneNoneFalseNoneFalse4176.480
4100757159777Nonecode41Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6593.136593.132.59FalseNoneNoneFalseNoneFalse17076.20670
4100758159777Nonecode42Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. BuildingsTonne94869.1594869.155.09FalseNoneNoneFalseNoneFalse482883.97350
4100759159777Nonecode43Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing usage charges of machinery etc complete as per specifications.Sqm1170.791170.79307.01FalseNoneNoneFalseNoneFalse359444.23790
4100760159777Nonecode44Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:3 (1 cement : 3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1063.681063.6818.89FalseNoneNoneFalseNoneFalse20092.91520
4100761159777Nonecode45Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum104793.31104793.310.34FalseNoneNoneFalseNoneFalse35629.72540
4100762159777Nonecode46Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.No1077.471077.475.0FalseNoneNoneFalseNoneFalse5387.350
4100763159777Nonecode47Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 35 mm thick one side teak and one side commercialSqm4132.774132.7715.12FalseNoneNoneFalseNoneFalse62487.48240
4100764159777Nonecode48Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mSqm , modulus of elasticity 900 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 125mmm802.2802.211.4FalseNoneNoneFalseNoneFalse9145.080
4100765159777Nonecode49Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/Cum and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mSqm , modulus of elasticity 850 N/mSqm and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately).Sqm4631.554631.553.15FalseNoneNoneFalseNoneFalse14589.38250
4100766159777Nonecode50Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm5716.15716.136.9FalseNoneNoneFalseNoneFalse210924.090
4100767159777Nonecode51Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm6004.956004.951.35FalseNoneNoneFalseNoneFalse8106.68250
4100768159777Nonecode52Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg178.16178.16954.45FalseNoneNoneFalseNoneFalse170044.8120
4100769159777Nonecode53Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm270.43270.43467.29FalseNoneNoneFalseNoneFalse126369.23470
4100770159777Nonecode54Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm408.29408.29412.68FalseNoneNoneFalseNoneFalse168493.11720
4100771159777Nonecode55Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm295.88295.8843.72FalseNoneNoneFalseNoneFalse12935.87360
4100772159777Nonecode56Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm106.05106.05657.0FalseNoneNoneFalseNoneFalse69674.850
4100773159777Nonecode57Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm134.68134.68657.0FalseNoneNoneFalseNoneFalse88484.760
4100774159777Nonecode58Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm184.53184.53314.19FalseNoneNoneFalseNoneFalse57977.48070
4100775159777Nonecode59Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm300.21300.2198.5FalseNoneNoneFalseNoneFalse29570.6850
4100776159777Nonecode60Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm56.2156.2121.17FalseNoneNoneFalseNoneFalse1189.96570
4100777159777Nonecode61Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm146.35146.3521.17FalseNoneNoneFalseNoneFalse3098.22950
4100778159777Nonecode62Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm121.96121.9643.29FalseNoneNoneFalseNoneFalse5279.64840
4100779159777Nonecode63Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mmSqm1246.091246.09140.74FalseNoneNoneFalseNoneFalse175374.70660
4100780159777Nonecode64Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Sqm2211.142211.1470.89FalseNoneNoneFalseNoneFalse156747.71460
4100781159777Nonecode65Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.m347.84347.8437.01FalseNoneNoneFalseNoneFalse12873.55840
4100782159777Nonecode66Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete.Sqm933.45933.4510.53FalseNoneNoneFalseNoneFalse9829.22850
4100783159777Nonecode67Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1461.61461.645.97FalseNoneNoneFalseNoneFalse67189.7520
4100784159777Nonecode68Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg146.35146.3564.8FalseNoneNoneFalseNoneFalse9483.480
4100785159777Nonecode69Newly Constructed Roof/Bathroom/Toilet/balcony/utility with Cementatius Waterproof coating - Below 500 Sqm Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface like Roof, bathroom, toilet, balcony & utility area applied @ 2.2kg/Sqm in 2 coats to achieve 1.2mm DFT, having Elongation at break less than120% as per ASTM D 412, Tensile strength less than1N/ mSqm as per ASTM D 412, Adhesion strength: 0.80N/mSqm as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification.Sqm556.76556.7610.53FalseNoneNoneFalseNoneFalse5862.68280
4100786159777Nonecode70Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal remittance tested as per ASTM) C 1549 and ASTM C 1371 respectively), VOC less than 10 cc/g. The coating thickness and the methodology of application shall strictly as per manufacturer's specifications and as approved by Engineer-in-Charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., washing with water all complete. The contractor shall give guarantee for the performance of SRI and also the durability of coating, all complete as per direction of Engineer-in-Charge.Sqm431.62431.62215.53FalseNoneNoneFalseNoneFalse93027.05860
4100787159777Nonecode71Providing and fixing 6mm Clear/opal white/solar bronze/blue/green tinted Multi wall poly carbonate sheet for Tubular structure. The work including cost of all materials, labour charges and usage charges of machinery for cutting, welding, grinding and erection equipments, with all lead, transportation, loading and unloading and all other incidental charges etc. complete as per specification and directions of the Engineer in charge of the work.Sqm3314.063314.0619.2FalseNoneNoneFalseNoneFalse63629.9520
4100788159777Nonecode72Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Kg119.84119.84410.0FalseNoneNoneFalseNoneFalse49134.40
4100789159777Nonecode73Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNo251.34251.348.0FalseNoneNoneFalseNoneFalse2010.720
4100790159777Nonecode74Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 100x70x4 mm (ordinary type)No148.47148.4724.0FalseNoneNoneFalseNoneFalse3563.280
4100791159777Nonecode75Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNo137.87137.878.0FalseNoneNoneFalseNoneFalse1102.960
4100792159777Nonecode76Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.No127.26127.268.0FalseNoneNoneFalseNoneFalse1018.080
4100793159777Nonecode77Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum107.1107.152.2FalseNoneNoneFalseNoneFalse5590.620
4100794159777Nonecode78Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum168.0168.052.2FalseNoneNoneFalseNoneFalse8769.60
4100795159777Nonecode79Providing and fixing brass bib cock of approved quality : 20 mm nominal boreNo320.25320.2512.0FalseNoneNoneFalseNoneFalse3843.00
4100796159777Nonecode80Providing and fixing in position brass PUSH cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (In Hand Wash) DRNo168.0168.010.0FalseNoneNoneFalseNoneFalse1680.00
4100797159777Nonecode81Providing and fixing brass stop cock of approved quality :20 mm nominal boreNo320.25320.255.0FalseNoneNoneFalseNoneFalse1601.250
4100798159777Nonecode82Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :40 mm nominal boreNo737.1737.11.0FalseNoneNoneFalseNoneFalse737.10
4100799159777Nonecode83Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :50 mm nominal boreNo897.75897.751.0FalseNoneNoneFalseNoneFalse897.750
4100800159777Nonecode84Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal boreNo329.7329.71.0FalseNoneNoneFalseNoneFalse329.70
4100801159777Nonecode85Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal boreNo348.6348.61.0FalseNoneNoneFalseNoneFalse348.60
4100802159777Nonecode86Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal bore HorizontalNo651.0651.01.0FalseNoneNoneFalseNoneFalse651.00
4100803159777Nonecode87Providing and fixing gun metal non- return valve of approved quality (screwed end) :32 mm nominal bore VerticalNo849.45849.451.0FalseNoneNoneFalseNoneFalse849.450
4100804159777Nonecode88Providing and fixing unplasticised PVC connection pipe with brass unions : 30 cm length 15 mm nominal boreNo87.1587.153.0FalseNoneNoneFalseNoneFalse261.450
4100805159777Nonecode89Providing and fixing Chlorinated Polyveny Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipesm397.95397.9540.0FalseNoneNoneFalseNoneFalse15918.00
4100806159777Nonecode90Providing and fixing Chlorinated Polyveny Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipesm500.85500.8530.0FalseNoneNoneFalseNoneFalse15025.50
4100807159777Nonecode91Providing and fixing Chlorinated Polyveny Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipesm584.85584.8522.0FalseNoneNoneFalseNoneFalse12866.70
4100808159777Nonecode92Providing and fixing Chlorinated Polyveny Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipesm333.9333.950.0FalseNoneNoneFalseNoneFalse16695.00
4100809159777Nonecode93Providing and fixing Chlorinated Polyveny Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipesm420.0420.030.0FalseNoneNoneFalseNoneFalse12600.00
4100810159777Nonecode94Providing and fixing in position / brass / gun metal easy clean strainer of approved make with stainless steel strainer etc.., complete -PVC- Supreme/Prince / Maheshm3858.03858.02.0FalseNoneNoneFalseNoneFalse7716.00
4100811159777Nonecode95Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.m52.552.520.0FalseNoneNoneFalseNoneFalse1050.00
4100812159777Nonecode96Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameterm305.55305.5540.0FalseNoneNoneFalseNoneFalse12222.00
4100813159777Nonecode97Providing, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651:1992, IS 4127 with latest amendments, including conveying to work site, caulking with hemp dipped in tar and jointing with CM 1:1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying of sewer lines etc. complete. The contractor will make own arrangements for procuring water for testing. 150 mm dia. pipesm610.05610.0530.0FalseNoneNoneFalseNoneFalse18301.50
4100814159777Nonecode98Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.Each5030.555030.552.0FalseNoneNoneFalseNoneFalse10061.10
4100815159777Nonecode99Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..Each5726.75726.72.0FalseNoneNoneFalseNoneFalse11453.40
4100816159777Nonecode100KSRB 12-7.1: Making connection of drain or sewer line of size 100 to 230mm external dia with existing manhole including breaking into and making good the walls, floors with cement concrete M 15 with 20mm and downsize granite metal, cement plastered on both sides of mix 1:3, finished with a floating coat of neat cement, and making necessary channels for the drain, including cost of materials, labour charges, curing complete as per specifications. Specification No KBSNo2828.72828.71.0FalseNoneNoneFalseNoneFalse2828.70
4100817159777Nonecode101Providing and fixing white vitreous china wash basin including making all connections but including the cost of fittings :Flat back wash basin of size 630x450 mmEach1035.31035.33.0FalseNoneNoneFalseNoneFalse3105.90
4100818159777Nonecode102C.P. Brass piller tap elbow operated for sinksUnit650.0650.03.0FalseNoneNoneFalseNoneFalse1950.00
4100819159777Nonecode103Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mmEach1068.91068.98.0FalseNoneNoneFalseNoneFalse8551.20
4100820159777Nonecode104600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each520.8520.88.0FalseNoneNoneFalseNoneFalse4166.40
4100821159777Nonecode105Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot). --do-10cms x 7.5cmsEach262.5262.520.0FalseNoneNoneFalseNoneFalse5250.00
4100822159777Nonecode106Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.l9.459.454000.0FalseNoneNoneFalseNoneFalse37800.00
4100823159777Nonecode107Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach5128.25128.22.0FalseNoneNoneFalseNoneFalse10256.40
4100824159777Nonecode108Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach6275.856275.853.0FalseNoneNoneFalseNoneFalse18827.550
4100825159777Nonecode109Supplying and fixing of 2/1.5 H.P. Monolbock Pump of approved make with all accessories conforming to ISI specification including cost of all materials, labour, with all lead and lift etc. complete as per directions of the Engineer-in-cahrge of the work. With all lead and lifts etc., complete as per specification and as per the directions of the Engineer- In-Charge of the work.No11443.9511443.951.0FalseNoneNoneFalseNoneFalse11443.950
4100826159777Nonecode110Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameterm343.38343.3830.0FalseNoneNoneFalseNoneFalse10301.40
4100827159777Nonecode111Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thickm66.066.0300.0FalseNoneNoneFalseNoneFalse19800.00
4100828159777Nonecode112Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thickm78.078.0100.0FalseNoneNoneFalseNoneFalse7800.00
4100829159777Nonecode113Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 32 mm dia 2.5 mm thickm103.0103.050.0FalseNoneNoneFalseNoneFalse5150.00
4100830159777Nonecode114Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 40 mm dia 2.5 mm thickm147.0147.030.0FalseNoneNoneFalseNoneFalse4410.00
4100831159777Nonecode115Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 75 x 75 x 65 mmEach106.0106.06.0FalseNoneNoneFalseNoneFalse636.00
4100832159777Nonecode116Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 100 x 75 x 65 mmEach118.0118.04.0FalseNoneNoneFalseNoneFalse472.00
4100833159777Nonecode117Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 135 x 75 x 65 mmEach139.0139.01.0FalseNoneNoneFalseNoneFalse139.00
4100834159777Nonecode118Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 180 x 90 x 65 mmEach161.0161.03.0FalseNoneNoneFalseNoneFalse483.00
4100835159777Nonecode119Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 200 x 90 x 65 mmEach179.0179.01.0FalseNoneNoneFalseNoneFalse179.00
4100836159777Nonecode120Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 200 x 200 x 65 mmEach348.0348.01.0FalseNoneNoneFalseNoneFalse348.00
4100837159777Nonecode121Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction boxEach49.049.040.0FalseNoneNoneFalseNoneFalse1960.00
4100838159777Nonecode122Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction boxEach56.056.020.0FalseNoneNoneFalseNoneFalse1120.00
4100839159777Nonecode123Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wallm29.029.0180.0FalseNoneNoneFalseNoneFalse5220.00
4100840159777Nonecode124Supplying And Fixing Metal Fan Box with Round Hook.No117.0117.020.0FalseNoneNoneFalseNoneFalse2340.00
4100841159777Nonecode125Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3M from tapping point to out let via switch boxPoint269.0269.010.0FalseNoneNoneFalseNoneFalse2690.00
4100842159777Nonecode126Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3M upto 6M from tapping point to out let via switch boxPoint379.0379.05.0FalseNoneNoneFalseNoneFalse1895.00
4100843159777Nonecode127Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 sqmmm26.026.0900.0FalseNoneNoneFalseNoneFalse23400.00
4100844159777Nonecode128Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 sqmmm42.042.0600.0FalseNoneNoneFalseNoneFalse25200.00
4100845159777Nonecode129Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 sqmmm63.063.0200.0FalseNoneNoneFalseNoneFalse12600.00
4100846159777Nonecode130Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 6 sqmmm92.092.0180.0FalseNoneNoneFalseNoneFalse16560.00
4100847159777Nonecode131Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required Nos of machine screws, bolts nuts etc., complete on the existing metal/PVC box.3 ModuleEach161.0161.06.0FalseNoneNoneFalseNoneFalse966.00
4100848159777Nonecode132Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required Nos of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleEach175.0175.04.0FalseNoneNoneFalseNoneFalse700.00
4100849159777Nonecode133Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required Nos of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach234.0234.01.0FalseNoneNoneFalseNoneFalse234.00
4100850159777Nonecode134Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required Nos of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach284.0284.03.0FalseNoneNoneFalseNoneFalse852.00
4100851159777Nonecode135Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required Nos of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach363.0363.01.0FalseNoneNoneFalseNoneFalse363.00
4100852159777Nonecode136Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required Nos of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 16 ModuleEach397.0397.01.0FalseNoneNoneFalseNoneFalse397.00
4100853159777Nonecode137Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way SwitchEach102.0102.0100.0FalseNoneNoneFalseNoneFalse10200.00
4100854159777Nonecode138Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way SwitchEach166.0166.02.0FalseNoneNoneFalseNoneFalse332.00
4100855159777Nonecode139Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleEach357.0357.040.0FalseNoneNoneFalseNoneFalse14280.00
4100856159777Nonecode140Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way SwitchEach180.0180.030.0FalseNoneNoneFalseNoneFalse5400.00
4100857159777Nonecode141Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP SwitchEach326.0326.020.0FalseNoneNoneFalseNoneFalse6520.00
4100858159777Nonecode142Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal SocketEach236.0236.025.0FalseNoneNoneFalseNoneFalse5900.00
4100859159777Nonecode143Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone SocketEach156.0156.01.0FalseNoneNoneFalseNoneFalse156.00
4100860159777Nonecode144Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box.Each646.0646.01.0FalseNoneNoneFalseNoneFalse646.00
4100861159777Nonecode145Supplying fully automatic star-delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 V 3 phase and wired after fixing to the existing wooden board for motor. upto 12.5 HPEach7455.07455.01.0FalseNoneNoneFalseNoneFalse7455.00
4100862159777Nonecode146Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SPEach415.0415.03.0FalseNoneNoneFalseNoneFalse1245.00
4100863159777Nonecode147Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DPEach739.0739.02.0FalseNoneNoneFalseNoneFalse1478.00
4100864159777Nonecode148Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 12 Way SP & NEach2329.02329.03.0FalseNoneNoneFalseNoneFalse6987.00
4100865159777Nonecode149Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. III - Double Door 4 Way TP & NEach4038.04038.02.0FalseNoneNoneFalseNoneFalse8076.00
4100866159777Nonecode150Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each9255.09255.01.0FalseNoneNoneFalseNoneFalse9255.00
4100867159777Nonecode151Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Stripsm3435.03435.03.0FalseNoneNoneFalseNoneFalse10305.00
4100868159777Nonecode152Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 400 A 4 x 50 x 10 mm Aluminium Stripsm4445.04445.01.0FalseNoneNoneFalseNoneFalse4445.00
4100869159777Nonecode153Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyEach9315.09315.01.0FalseNoneNoneFalseNoneFalse9315.00
4100870159777Nonecode154Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired.Each4390.04390.01.0FalseNoneNoneFalseNoneFalse4390.00
4100871159777Nonecode155Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Job3750.03750.01.0FalseNoneNoneFalseNoneFalse3750.00
4100872159777Nonecode156Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kmsm139.54139.5435.0FalseNoneNoneFalseNoneFalse4883.90
4100873159777Nonecode157Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe/ on wall/on pole as required.m23.6423.6435.0FalseNoneNoneFalseNoneFalse827.40
4100874159777Nonecode158Digging of trench of 0.6m deep x 0.50 M wide refilling the trench to the required ground level and consolidating etc.,complete.m889.0889.035.0FalseNoneNoneFalseNoneFalse31115.00
4100875159777Nonecode159Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mm58.058.035.0FalseNoneNoneFalseNoneFalse2030.00
4100876159777Nonecode160Epoxy Terminating Kit (Pothead) suitable for 1.1KV,LTUG cableEach382.0382.010.0FalseNoneNoneFalseNoneFalse3820.00
4100877159777Nonecode161Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm)Each2969.02969.04.0FalseNoneNoneFalseNoneFalse11876.00
4100878159777Nonecode162Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modelEach2984.02984.035.0FalseNoneNoneFalseNoneFalse104440.00
4100879159777Nonecode163Supplying of .....feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI less than 80. Power Input: 220-240V@ 50/60Hz & Power factor less than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach690.0690.020.0FalseNoneNoneFalseNoneFalse13800.00
4100880159777Nonecode164Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI less than 80. Power Input: 220-240V @50/60Hz & Power factor less than0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach885.0885.025.0FalseNoneNoneFalseNoneFalse22125.00
4100881159777Nonecode165Supplying and fixing of 5'-80 W of T8 Fluorescent Tube with 54W power consumption with low 3mg Mercury content less phosphor coating Operating voltage range from 180V to 265V, 50Hz AC power SupplyNo520.0520.030.0FalseNoneNoneFalseNoneFalse15600.00
4100882159777Nonecode166Supplying of patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired with HF Electronic Ballast, Operating voltage range from 180V to 265V, 50Hz AC power supply excluding Tube. 1 x 4' Tube light fitting.Each340.0340.020.0FalseNoneNoneFalseNoneFalse6800.00
4100883159777Nonecode167Supplying & Fixing of 70-150 W lamp holder 2 PinNo63.063.015.0FalseNoneNoneFalseNoneFalse945.00
4100884159777Nonecode168Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / GirdersEach122.0122.075.0FalseNoneNoneFalseNoneFalse9150.00
4100885159777Nonecode169Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each315.0315.035.0FalseNoneNoneFalseNoneFalse11025.00
4100886159777Nonecode170Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each707.0707.04.0FalseNoneNoneFalseNoneFalse2828.00
4100887159777Nonecode171Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.Each490.0490.025.0FalseNoneNoneFalseNoneFalse12250.00
4100888159777Nonecode172Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.Each562.0562.02.0FalseNoneNoneFalseNoneFalse1124.00
4100889159777Nonecode173Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each515.0515.03.0FalseNoneNoneFalseNoneFalse1545.00
4100890159777Nonecode174Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum107.1107.139.59FalseNoneNoneFalseNoneFalse4240.0890
4100891159777Nonecode175Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.31.36FalseNoneNoneFalseNoneFalse379.8480
4100892159777Nonecode176Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5891.555891.558.99FalseNoneNoneFalseNoneFalse52965.03450
4100893159777Nonecode177Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.Cum2816.12816.15.03FalseNoneNoneFalseNoneFalse14164.9830
4100894159777Nonecode178Brick BatsSqm840.0840.04.42FalseNoneNoneFalseNoneFalse3712.80
4100895159777Nonecode179Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10777.7310777.731.14FalseNoneNoneFalseNoneFalse12286.61220
4100896159777Nonecode180Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. BuildingsTonne93929.8593929.850.18FalseNoneNoneFalseNoneFalse16907.3730
4100897159777Nonecode181Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 140mm dia., 6 kg/sqcm & class 3m613.2613.22.0FalseNoneNoneFalseNoneFalse1226.40
4100898159777Nonecode182Providing to work spot rolling, lowering and placing in position RCC perforated rings in the already excavated pit including loading and unloading at both the destinations with all lead and lift with appurtenances., complete.Sqm6464.856464.852.0FalseNoneNoneFalseNoneFalse12929.70
4100899159777Nonecode183Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete.Each5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
4100900159777Nonecode184Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 0 to 50 Msm388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
4100901159777Nonecode185Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 200mm dia., 6 kg/sqcm & class 3m1170.751170.7550.0FalseNoneNoneFalseNoneFalse58537.50
4100902159777Nonecode186Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsEach157.5157.51.0FalseNoneNoneFalseNoneFalse157.50
4100903159777Nonecode187Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeEach172.2172.21.0FalseNoneNoneFalseNoneFalse172.20
4100904159777Nonecode188Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 135 LPM @ 56 m = 8 STG Outlet Dia - 2.00"Each27205.527205.51.0FalseNoneNoneFalseNoneFalse27205.50
4100905159777Nonecode189Supply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments. Size 100 mmEach16695.016695.01.0FalseNoneNoneFalseNoneFalse16695.00
4100906159777Nonecode190Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. Heavy Duty GI pipe of 40mm diam522.9522.950.0FalseNoneNoneFalseNoneFalse26145.00
4100907159777Nonecode191Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for: For 40 mm dia GI elbowEach216.3216.32.0FalseNoneNoneFalseNoneFalse432.60
4100908159777Nonecode192Submersible calbes PVC 1x3x2.50sq.mm189.0189.060.0FalseNoneNoneFalseNoneFalse11340.00
4100909159777Nonecode193Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.Job6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
4100910159777Nonecode194Providing Main connection from poll PVC insulated sheathed steel/wire cable 3.5x10 including cost of all materials with all lead and lifts loading and unloading charges, cost of labour, HOM charges of all machineries incidental and equipment charges and implementation of environmental and social safeguards etc complete and as per the direction of engineer in charge of work.m60.960.970.0FalseNoneNoneFalseNoneFalse4263.00
4100911159777Nonecode195Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.Each1417.51417.51.0FalseNoneNoneFalseNoneFalse1417.50
4100912159777Nonecode196Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Job3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
4100913159777Nonecode197PART A Supply and erection of PSC Pole-9.0m Long, 200Kg WL, Errection of RCC/PSC Poles 9 to 10M Long but in a pit of 1.8M depthNos6067.826067.825.0FalseNoneNoneFalseNoneFalse30339.10
4100914159777Nonecode198excavation in Ordinary SoilNos629.0629.05.0FalseNoneNoneFalseNoneFalse3145.00
4100915159777Nonecode199Supply and erection of RCC Pole-9.0M Long, 145kg WL Errection of RCC/PSC Poles 9 to 10M Long but in a pit of 1.8M depthNos9462.689462.6820.0FalseNoneNoneFalseNoneFalse189253.60
4100916159777Nonecode200excavation in Ordinary SoilNos629.0629.020.0FalseNoneNoneFalseNoneFalse12580.00
4100917159777Nonecode201Supply and Erection of 11KV Horizontal cross arm with, Fixing of V-Shape/Horizontal Cross arm including single top support Braces and insulators fixingNos1019.281019.285.0FalseNoneNoneFalseNoneFalse5096.40
4100918159777Nonecode202Supply and Erection of 11KV Horizontal cross arm with, Fixing of V-Shape/Horizontal Cross arm including single top support Braces and insulators fixingNos1015.741015.7424.0FalseNoneNoneFalseNoneFalse24377.760
4100919159777Nonecode203Supply and Erection of Guy with complete set, Fixing of Guy Sets with break insulators making use of 7/3.15mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawingSet1646.61646.68.0FalseNoneNoneFalseNoneFalse13172.80
4100920159777Nonecode204Excavation in Ordinary SoilSet327.0327.08.0FalseNoneNoneFalseNoneFalse2616.00
4100921159777Nonecode205Supply and Erection of 11KV, 5KNNos241.9241.960.0FalseNoneNoneFalseNoneFalse14514.00
4100922159777Nonecode206Supply and Installation of Silcon rubber composite insulaNos219.48219.4830.0FalseNoneNoneFalseNoneFalse6584.40
4100923159777Nonecode207Supply and Installation of Rabbit ACSR Conductor, For rabbit ACSRm73.4273.423500.0FalseNoneNoneFalseNoneFalse256970.00
4100924159777Nonecode208Supply and Erection of 9M RCC DP Transformer stct, Erection of pole upto 63kVA with 9Ms. RCC poleNos42958.7242958.721.0FalseNoneNoneFalseNoneFalse42958.720
4100925159777Nonecode209Excavation in Ordinary SoilNos629.0629.02.0FalseNoneNoneFalseNoneFalse1258.00
4100926159777Nonecode210Supply and Installation of SWG G.I. WireKg88.5488.545.0FalseNoneNoneFalseNoneFalse442.70
4100927159777Nonecode211Supply and Installation of SWG Guy wireKg91.1391.1310.0FalseNoneNoneFalseNoneFalse911.30
4100928159777Nonecode212Supply and Erection of Guy with complete set, Fixing of Guy Sets with break insulators making use of 7/3.15mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawingSet1646.61646.61.0FalseNoneNoneFalseNoneFalse1646.60
4100929159777Nonecode213Excavation in Ordinary SoilSet327.0327.01.0FalseNoneNoneFalseNoneFalse327.00
4100930159777Nonecode214Supply and Installation of Earthing Materials type for grounding, Ordinary SoilNos2488.02488.03.0FalseNoneNoneFalseNoneFalse7464.00
4100931159777Nonecode215Supply and Installation of Providing GI Pipe Earting for lighting arresters Transformer Neutral and Transformer metal parts (Excluding digging of pits)Nos190.0190.03.0FalseNoneNoneFalseNoneFalse570.00
4100932159777Nonecode216Supply and Erection of 11 kVA, 5KNNos241.9241.93.0FalseNoneNoneFalseNoneFalse725.70
4100933159777Nonecode217Supply and Installation of Silcon rubber composite insulaNos219.48219.483.0FalseNoneNoneFalseNoneFalse658.440
4100934159777Nonecode218Supply and Installation of LT Spacer for TC WiringNos49.5649.564.0FalseNoneNoneFalseNoneFalse198.240
4100935159777Nonecode219Supply and Installation of 95sq.mm (P.G. clamps rabbit),Nos165.2165.24.0FalseNoneNoneFalseNoneFalse660.80
4100936159777Nonecode220Wiring of one circuit of LT wiring Kit for 25/63/100KVA DTC to the existing LT protection kit / Distribution boxvia metering boxNos949.0949.01.0FalseNoneNoneFalseNoneFalse949.00
4100937159777Nonecode221Supply and Installation of LT Protection kit, Fixing of LT Protection KitNos2743.142743.142.0FalseNoneNoneFalseNoneFalse5486.280
4100938159777Nonecode222Supply and Installation of 11KV D.O.L.O. cutouts convent, fixing 11KV D.O.L.O. cutouts/ Horn GapFuses including fixing of cross arms and wiringSet7169.57169.51.0FalseNoneNoneFalseNoneFalse7169.50
4100939159777Nonecode223Supply and Installation of L.A. 9kV, 5KA, Metal OxideNos1869.121869.123.0FalseNoneNoneFalseNoneFalse5607.360
4100940159777Nonecode224Fixing of 3 Nos lighting arrestors including wiring.Nos119.0119.01.0FalseNoneNoneFalseNoneFalse119.00
4100941159777Nonecode225Supply and Installation of 11KV GOS 200A single break, Fixing of GOS incuding wiring (11kV SB200A)Set12255.012255.01.0FalseNoneNoneFalseNoneFalse12255.00
4100942159777Nonecode226Supply and Installation of 63kVA, aluminum wdg, BEE-4 sta, Erectionof 25063kVA Transformer on Transformer structureNos206193.0206193.01.0FalseNoneNoneFalseNoneFalse206193.00
4100943159777Nonecode227Supply and Installation of LT Electronic Tri-Vector met, LT Electroic Tri-Vector Meter 5A, class-0.5/1.0 AccuracyNos4194.04194.01.0FalseNoneNoneFalseNoneFalse4194.00
4100944159777Nonecode228Supply and Installation of with CT Ratio 100/5for50/63, LT Metering box for housing ETV meter with CTm8075.748075.741.0FalseNoneNoneFalseNoneFalse8075.740
4100945159777Nonecode229Supply and Installation of AL lead wire 95sq.mmm111.29111.2940.0FalseNoneNoneFalseNoneFalse4451.60
4100946159777Nonecode230Supply and Erection of PSC Pole-8.0m Long, 200Kg WL, Ordinary soilNos4867.824867.821.0FalseNoneNoneFalseNoneFalse4867.820
4100947159777Nonecode231Supply and Erection of Same as above but Errection of RCC/PSC Poles 7.5 to 8M Long but in a pit of 1.5M depthNos922.0922.01.0FalseNoneNoneFalseNoneFalse922.00
4100948159777Nonecode232Supply and Erection of RCC Pole-8.0M Long, 115kg WL, Ordinary soilNos6555.226555.221.0FalseNoneNoneFalseNoneFalse6555.220
4100949159777Nonecode233Supply and Erection of Same as above but Errection of RCC/PSC Poles 7.5 to 8M Long but in a pit of 1.5M depthNos922.0922.01.0FalseNoneNoneFalseNoneFalse922.00
4100950159777Nonecode234Supply and Installation of 4 Pin cross arm with pole clamp, Fixing of 4 pin cross arm with insulator andbracesNos659.14659.141.0FalseNoneNoneFalseNoneFalse659.140
4100951159777Nonecode235Supply and Installation of 4 Pin cross arm with pole clamp, Fixing of 4 pin cross arm with insulator andbracesNos655.6655.62.0FalseNoneNoneFalseNoneFalse1311.20
4100952159777Nonecode236Supply and Installation of Guy with complete set, Fixing of Guy Sets with break insulators making use of 7/3.15mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawingSet1646.61646.62.0FalseNoneNoneFalseNoneFalse3293.20
4100953159777Nonecode237Excavation in Ordinary SoilSet327.0327.02.0FalseNoneNoneFalseNoneFalse654.00
4100954159777Nonecode238Supply and Installation of 1.1 kV pin insulator (Shell on,Nos36.5836.588.0FalseNoneNoneFalseNoneFalse292.640
4100955159777Nonecode239Supply and Installation of 1.1kV pininsulator (G.I. pinNos41.341.38.0FalseNoneNoneFalseNoneFalse330.40
4100956159777Nonecode240Supply and Installation of No8 Strain InslatorNos31.8631.868.0FalseNoneNoneFalseNoneFalse254.880
4100957159777Nonecode241Supply and Installation of Weasel ACSR Conductor, Strining of conductor wren,squirrel,weaset, binding of conductor on each insulator and dead endingon strain or disc/strain insulator by means of clamps.m44.8844.88410.0FalseNoneNoneFalseNoneFalse18400.80
4100958159777Nonecode242Kalyana karnataka chargesNos161710.11161710.111.0FalseNoneNoneFalseNoneFalse161710.110
4100959159777Nonecode243Deposit 20 kWNos37800.037800.01.0FalseNoneNoneFalseNoneFalse37800.00
4100960159777Nonecode244Electrical Inspected chargesNos20000.020000.01.0FalseNoneNoneFalseNoneFalse20000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17275154510000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17275154510000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17275154510000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17275154510000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17275154510000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneWork done certificate for satisfactorily completed as prime contractor, at least one similar work comprising of Building costing Rs.33.765 lakhs from competent authorities not below the rank of Executive Engineer or equivalent list of such works in FORMAT-2Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneCertificate issued by the competent authority not below the rank of Executive Engineer for having executed in any one year,for a continuous period of 12 months the following minimum quantities of work To qualify for award of this contract, each Tenderer in its name should have in the last five years i.e 2019-20. 2020-21, 2021-22,2022-23 & 2023-24 executed in any one year, the following minimum quantities of work RCC/PCC 69.25 Cum Plastering 768.01 Sqm Flooring 465.10 Sqm Steel- 5.08 tonnePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information in the prescribed format and certificate from the competent authority.
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e.2019-20. 2020-21, 2021-22,2022-23 & 2023-24 a achieved in at least two financial years an average annual financial turnover in all classes of civil engineering construction works only usually not less than the estimated annual payments under this contract of Rs.67.53 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneCopy of Registration for having registered in PWDCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneTenderers who meet the above specified minimum qualifying criteria will only be qualified if their available tender capacity is more than the total tender value The available tender capacity will be calculated as under Assessed available tender capacity AXNX2.5-BwhereA is Maximum value of civil engineering works executed in any one year during the last five yearsupdated to price level taking into account the completed as well as works in progressN is Number of years prescribed for completion of the works for which Tenders are invitedB is Value at price level of existing commitments and on-going works to be completed during the next years period of completion of the works for which Tenders are invitedFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid Assets and or availability of credit facilities of no less than Rs. 20.26 Lakhs Credit Lines/letter of credit/ certificates from the banks for meeting the fund requirement etcFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneThe information on litigation in which the Tenderer is involved are to be furnished.OthersLITIGATION
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The information on litigation in which the Tenderer is involved are to be furnished.
NoneNoneNoneNoneName, address, and telephone, telex, and fax numbers of the tenderers bankers who may provide references if contacted by the employer.OthersADDRESS
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Name, address, and telephone, telex, and fax numbers of the tenderers bankers who may provide references if contacted by the employer.
NoneNoneNoneNoneThe information of the works for which tenderer has already submitted tender are to be furnished.OthersTENDERED WORKS
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The information of the works for which tenderer has already submitted tender are to be furnished.
NoneNoneNoneNoneExisting commitments and ongoing works which are yet to be completedOthersNEW WORKS
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Existing commitments and ongoing works which are yet to be completed
NoneNoneNoneNoneThe works for which tender acceptance letters are received are to be furnishedOthersTENDERED WORKS
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The works for which tender acceptance letters are received are to be furnished
NoneNoneNoneNoneInformation on Existing commitments and on going works which are yet to be completedOthersCOMMITTED WORKS
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information on Existing commitments and on going works which are yet to be completed
NoneNoneNoneNoneA site engineer having B.E Civil with minimum experience of 5 years in construction or Diploma in Civil Engineering with minimum experience of 8 years in construction.OthersTECHNICAL STATUS
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information in the prescribed format supported by Degree/Diploma certificates & experience certificate
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Valid PWD Registration certificateTrueTechnical Bid
To qualify for award of this contract, each Tenderer in his name should have in the last five years i.e.2019-20. 2020-21, 2021-22,2022-23 & 2023-24 a achieved in at least two financial years an average annual financial turnover in all classes of civil engineering construction works only usually not less than the estimated annual payments under this contract of Rs.67.53 LakhsTrueTechnical Bid
To qualify for award of this contract, each Tenderer in its name should have in the last five years i.e 2019-20. 2020-21, 2021-22,2022-23 & 2023-24 executed in any one year, the following minimum quantities of work RCC/PCC 69.25 Cum Plastering 768.01 Sqm Flooring 465.10 Sqm Steel- 5.08 tonneTrueTechnical Bid
Work done certificate for satisfactorily completed as prime contractor, at least one similar work comprising of Building costing Rs.33.765 lakhs from competent authorities not below the rank of Executive Engineer or equivalent list of such works in FORMAT-2TrueTechnical Bid
Liquid Assets and or availability of credit facilities of no less than Rs. 20.26 Lakhs Credit Lines/letter of credit/ certificates from the banks for meeting the fund requirement etcTrueTechnical Bid
A site engineer having B.E Civil with minimum experience of 5 years in construction or Diploma in Civil Engineering with minimum experience of 8 years in construction.TrueTechnical Bid
Tenderers who meet the above specified minimum qualifying criteria will only be qualified if their available tender capacity is more than the total tender value The available tender capacity will be calculated as under Assessed available tender capacity AXNX2.5-BTrueTechnical Bid
Information on Existing commitments and on going works which are yet to be completedTrueTechnical Bid
Existing commitments and ongoing works which are yet to be completedTrueTechnical Bid
The works for which tender acceptance letters are received are to be furnishedTrueTechnical Bid
The information of the works for which tenderer has already submitted tender are to be furnished.TrueTechnical Bid
The information on litigation in which the Tenderer is involved are to be furnished.TrueTechnical Bid
Name, address, and telephone, telex, and fax numbers of the tenderers bankers who may provide references if contacted by the employer.TrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone