4099694 | 159715 | None | code01 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge | Cum | 1746.15 | 1746.15 | 20.09 | False | None | None | False | None | False | 35080.1535 | 0 |
4099695 | 159715 | None | code02 | Demolishing stone rubble masonry manually/ by mechanical means
including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer in-charge In cement mortar | Cum | 1768.2 | 1768.2 | 49.7 | False | None | None | False | None | False | 87879.54 | 0 |
4099696 | 159715 | None | code03 | Construction of New Class Rooms to GMHPS @ Sirigeri Village in Sirguppa Taluka of Ballary Dist. Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work | Cum | 254.1 | 254.1 | 45.25 | False | None | None | False | None | False | 11498.025 | 0 |
4099697 | 159715 | None | code04 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work | Cum | 271.95 | 271.95 | 13.69 | False | None | None | False | None | False | 3722.9955 | 0 |
4099698 | 159715 | None | code05 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 4.55 | False | None | None | False | None | False | 28612.4475 | 0 |
4099699 | 159715 | None | code06 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) COLOUM FOOTING M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6852.38 | 6852.38 | 7.37 | False | None | None | False | None | False | 50502.0406 | 0 |
4099700 | 159715 | None | code07 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) COLOUM M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11309.76 | 11309.76 | 1.18 | False | None | None | False | None | False | 13345.5168 | 0 |
4099701 | 159715 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) COLUM Above GL M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12214.76 | 12214.76 | 2.86 | False | None | None | False | None | False | 34934.2136 | 0 |
4099702 | 159715 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) grade beam,plinth beam,toiletM20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10777.73 | 10777.73 | 7.29 | False | None | None | False | None | False | 78569.6517 | 0 |
4099703 | 159715 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) lintel ,roof beam M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11496.24 | 11496.24 | 4.93 | False | None | None | False | None | False | 56676.4632 | 0 |
4099704 | 159715 | None | code11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) chejjaand racks M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10418.47 | 10418.47 | 0.1 | False | None | None | False | None | False | 1041.847 | 0 |
4099705 | 159715 | None | code12 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) roof slab ,tolet slabM20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10777.73 | 10777.73 | 9.26 | False | None | None | False | None | False | 99801.7798 | 0 |
4099706 | 159715 | None | code13 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Tonne | 93929.85 | 93929.85 | 2.854 | False | None | None | False | None | False | 268075.7919 | 0 |
4099707 | 159715 | None | code14 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 9094.05 | 9094.05 | 3.74 | False | None | None | False | None | False | 34011.747 | 0 |
4099708 | 159715 | None | code15 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 8367.45 | 8367.45 | 18.16 | False | None | None | False | None | False | 151952.892 | 0 |
4099709 | 159715 | None | code16 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 279.3 | 279.3 | 32.14 | False | None | None | False | None | False | 8976.702 | 0 |
4099710 | 159715 | None | code17 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 496.52 | 496.52 | 62.49 | False | None | None | False | None | False | 31027.5348 | 0 |
4099711 | 159715 | None | code18 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete | Sqm | 4454.1 | 4454.1 | 9.0 | False | None | None | False | None | False | 40086.9 | 0 |
4099712 | 159715 | None | code19 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding14.3 | Kg | 176.4 | 176.4 | 198.45 | False | None | None | False | None | False | 35006.58 | 0 |
4099713 | 159715 | None | code20 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:2:4 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6463.8 | 6463.8 | 4.65 | False | None | None | False | None | False | 30056.67 | 0 |
4099714 | 159715 | None | code21 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching
pigments etc. complete Size of Tile 500x500 mm | Sqm | 1167.6 | 1167.6 | 61.9 | False | None | None | False | None | False | 72274.44 | 0 |
4099715 | 159715 | None | code22 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 292.95 | 292.95 | 78.03 | False | None | None | False | None | False | 22858.8885 | 0 |
4099716 | 159715 | None | code23 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 349.65 | 349.65 | 120.93 | False | None | None | False | None | False | 42283.1745 | 0 |
4099717 | 159715 | None | code24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 87.15 | 87.15 | 134.43 | False | None | None | False | None | False | 11715.5745 | 0 |
4099718 | 159715 | None | code25 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 133.35 | 133.35 | 255.36 | False | None | None | False | None | False | 34052.256 | 0 |
4099719 | 159715 | None | code26 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 136.5 | 136.5 | 75.6 | False | None | None | False | None | False | 10319.4 | 0 |
4099720 | 159715 | None | code27 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | cm | 4.2 | 4.2 | 1000.0 | False | None | None | False | None | False | 4200.0 | 0 |
4099721 | 159715 | None | code28 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter | m | 305.55 | 305.55 | 12.0 | False | None | None | False | None | False | 3666.6 | 0 |
4099722 | 159715 | None | code29 | Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 1 9/20 mm dia 2mm thick | m | 66.0 | 66.0 | 30.0 | False | None | None | False | None | False | 1980.0 | 0 |
4099723 | 159715 | None | code30 | Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick | m | 78.0 | 78.0 | 20.0 | False | None | None | False | None | False | 1560.0 | 0 |
4099724 | 159715 | None | code31 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.75x75x65mm | Each | 106.0 | 106.0 | 1.0 | False | None | None | False | None | False | 106.0 | 0 |
4099725 | 159715 | None | code32 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.100x75x75mm | Each | 179.0 | 179.0 | 2.0 | False | None | None | False | None | False | 358.0 | 0 |
4099726 | 159715 | None | code33 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.180X90X65mm | Each | 161.0 | 161.0 | 1.0 | False | None | None | False | None | False | 161.0 | 0 |
4099727 | 159715 | None | code34 | Supplying and fixing PVC/metal conduit Deep junction box 19/20mm Deep Junction Box | Each | 49.0 | 49.0 | 3.0 | False | None | None | False | None | False | 147.0 | 0 |
4099728 | 159715 | None | code35 | Supplying and fixing PVC/metal conduit Deep junction box 25mm Deep Junction Box | Each | 56.0 | 56.0 | 1.0 | False | None | None | False | None | False | 56.0 | 0 |
4099729 | 159715 | None | code36 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50mm Conduit in Brick Walls | m | 29.0 | 29.0 | 15.0 | False | None | None | False | None | False | 435.0 | 0 |
4099730 | 159715 | None | code37 | Supplying And Fixing Metal Fan Box with Round Hook | Nos | 160.0 | 160.0 | 2.0 | False | None | None | False | None | False | 320.0 | 0 |
4099731 | 159715 | None | code38 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694 and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.A Short piont up to 3 M from tapping piont out let via switch | Point | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 |
4099732 | 159715 | None | code39 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694 and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.A medium piont above 3M to 6 M from tapping piont out let via switch. | Point | 394.0 | 394.0 | 3.0 | False | None | None | False | None | False | 1182.0 | 0 |
4099733 | 159715 | None | code40 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694 and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.A medium piont above 6M to 10 M from tapping piont out let via switch. | Point | 570.0 | 570.0 | 1.0 | False | None | None | False | None | False | 570.0 | 0 |
4099734 | 159715 | None | code41 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694 confirming to latest amendments.1.5 Sqmm | m | 26.0 | 26.0 | 60.0 | False | None | None | False | None | False | 1560.0 | 0 |
4099735 | 159715 | None | code42 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694 confirming to latest amendments.2.5 Sqmm | m | 42.0 | 42.0 | 5.0 | False | None | None | False | None | False | 210.0 | 0 |
4099736 | 159715 | None | code43 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694 confirming to latest amendments.2.5 Sqmm | m | 63.0 | 63.0 | 8.0 | False | None | None | False | None | False | 504.0 | 0 |
4099737 | 159715 | None | code44 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box 1 to 3 Module | Each | 137.0 | 137.0 | 1.0 | False | None | None | False | None | False | 137.0 | 0 |
4099738 | 159715 | None | code45 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box 4 Module | Each | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 |
4099739 | 159715 | None | code46 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box 8Module | Each | 234.0 | 234.0 | 1.0 | False | None | None | False | None | False | 234.0 | 0 |
4099740 | 159715 | None | code47 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way | Each | 102.0 | 102.0 | 1.0 | False | None | None | False | None | False | 102.0 | 0 |
4099741 | 159715 | None | code48 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16 Amps one way | Each | 177.0 | 177.0 | 1.0 | False | None | None | False | None | False | 177.0 | 0 |
4099742 | 159715 | None | code49 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16Amps universal socket | Each | 156.0 | 156.0 | 4.0 | False | None | None | False | None | False | 624.0 | 0 |
4099743 | 159715 | None | code50 | Supplying and fixing 32A security and energy saving DPswitch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box. | Each | 646.0 | 646.0 | 1.0 | False | None | None | False | None | False | 646.0 | 0 |
4099744 | 159715 | None | code51 | Supplying &fixing of procelain fuse channel with cut out on existing wodden/panel using necessary nuts,bolts and washwer 32Amps | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 |
4099745 | 159715 | None | code52 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and c Type curve, indicator ON/OFF energy cross-3 withShort circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps SP | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 |
4099746 | 159715 | None | code53 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB s single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.14 Way SP & N | Each | 3088.0 | 3088.0 | 1.0 | False | None | None | False | None | False | 3088.0 | 0 |
4099747 | 159715 | None | code54 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 9255.0 | 9255.0 | 1.0 | False | None | None | False | None | False | 9255.0 | 0 |
4099748 | 159715 | None | code55 | Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired. | Each | 4390.0 | 4390.0 | 1.0 | False | None | None | False | None | False | 4390.0 | 0 |
4099749 | 159715 | None | code56 | Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc complete.250Amps 4x30x10mm Aluminium Strips | Each | 3435.0 | 3435.0 | 1.0 | False | None | None | False | None | False | 3435.0 | 0 |
4099750 | 159715 | None | code57 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. | Each | 690.0 | 690.0 | 4.0 | False | None | None | False | None | False | 2760.0 | 0 |
4099751 | 159715 | None | code58 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin | Each | 63.0 | 63.0 | 4.0 | False | None | None | False | None | False | 252.0 | 0 |
4099752 | 159715 | None | code59 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. | Each | 122.0 | 122.0 | 4.0 | False | None | None | False | None | False | 488.0 | 0 |
4099753 | 159715 | None | code60 | Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. | Nos | 490.0 | 490.0 | 4.0 | False | None | None | False | None | False | 1960.0 | 0 |
4099754 | 159715 | None | code61 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS-3741979 and with double ball bearing system.48" Sweep (1200mm) Regular model | Each | 2984.0 | 2984.0 | 2.0 | False | None | None | False | None | False | 5968.0 | 0 |
4099755 | 159715 | None | code62 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 315.0 | 315.0 | 2.0 | False | None | None | False | None | False | 630.0 | 0 |