4099042 | 159683 | None | code01 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m including cost of labour, tools and other apurtenances required to complete the work. | Cum | 254.1 | 254.1 | 58.4 | False | None | None | False | None | False | 14839.44 | 0 |
4099043 | 159683 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 16.0 | False | None | None | False | None | False | 100615.2 | 0 |
4099044 | 159683 | None | code03 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6838.32 | 6838.32 | 9.84 | False | None | None | False | None | False | 67289.0688 | 0 |
4099045 | 159683 | None | code04 | Additionalities for Formwork, Centering and scaffolding 3% for all foundations | Cum | 11286.56 | 11286.56 | 1.311 | False | None | None | False | None | False | 14796.68016 | 0 |
4099046 | 159683 | None | code05 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 8.49 | False | None | None | False | None | False | 50019.2595 | 0 |
4099047 | 159683 | None | code06 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 8.38 | False | None | None | False | None | False | 56216.811 | 0 |
4099048 | 159683 | None | code07 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12214.76 | 12214.76 | 3.78 | False | None | None | False | None | False | 46171.7928 | 0 |
4099049 | 159683 | None | code08 | Additionalities for Formwork, Centering and scaffolding 60% for Beams | Cum | 11496.24 | 11496.24 | 11.62 | False | None | None | False | None | False | 133586.3088 | 0 |
4099050 | 159683 | None | code09 | Additionalities for Formwork, Centering and scaffolding 45% for Chejjas | Cum | 10418.47 | 10418.47 | 0.837 | False | None | None | False | None | False | 8720.25939 | 0 |
4099051 | 159683 | None | code10 | Additionalities for Formwork, Centering and scaffolding 50% for Slab | Cum | 10777.73 | 10777.73 | 17.71 | False | None | None | False | None | False | 190873.5983 | 0 |
4099052 | 159683 | None | code11 | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 93929.85 | 93929.85 | 4.88 | False | None | None | False | None | False | 458377.668 | 0 |
4099053 | 159683 | None | code12 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 9094.05 | 9094.05 | 22.48 | False | None | None | False | None | False | 204434.244 | 0 |
4099054 | 159683 | None | code13 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 814.8 | 814.8 | 100.7 | False | None | None | False | None | False | 82050.36 | 0 |
4099055 | 159683 | None | code14 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 8.81 | False | None | None | False | None | False | 2460.633 | 0 |
4099056 | 159683 | None | code15 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 69.71 | False | None | None | False | None | False | 34694.667 | 0 |
4099057 | 159683 | None | code16 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 4454.1 | 4454.1 | 20.07 | False | None | None | False | None | False | 89393.787 | 0 |
4099058 | 159683 | None | code17 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 176.4 | 176.4 | 325.08 | False | None | None | False | None | False | 57344.112 | 0 |
4099059 | 159683 | None | code18 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 0.76 | False | None | None | False | None | False | 4961.166 | 0 |
4099060 | 159683 | None | code19 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1622.25 | 1622.25 | 108.76 | False | None | None | False | None | False | 176435.91 | 0 |
4099061 | 159683 | None | code20 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 933.45 | 933.45 | 10.12 | False | None | None | False | None | False | 9446.514 | 0 |
4099062 | 159683 | None | code21 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/Sqm, including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1161.3 | 1161.3 | 41.01 | False | None | None | False | None | False | 47624.913 | 0 |
4099063 | 159683 | None | code22 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 292.95 | 292.95 | 271.73 | False | None | None | False | None | False | 79603.3035 | 0 |
4099064 | 159683 | None | code23 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. | Sqm | 349.65 | 349.65 | 200.6 | False | None | None | False | None | False | 70139.79 | 0 |
4099065 | 159683 | None | code24 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 133.35 | 133.35 | 342.95 | False | None | None | False | None | False | 45732.3825 | 0 |
4099066 | 159683 | None | code25 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 186.9 | 186.9 | 200.6 | False | None | None | False | None | False | 37492.14 | 0 |
4099067 | 159683 | None | code26 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. | Cum | 6692.7 | 6692.7 | 3.87 | False | None | None | False | None | False | 25900.749 | 0 |
4099068 | 159683 | None | code27 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | cm | 4.2 | 4.2 | 1500.0 | False | None | None | False | None | False | 6300.0 | 0 |
4099069 | 159683 | None | code28 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 2764.65 | 2764.65 | 8.0 | False | None | None | False | None | False | 22117.2 | 0 |
4099070 | 159683 | None | code29 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | m | 333.9 | 333.9 | 17.1 | False | None | None | False | None | False | 5709.69 | 0 |
4099071 | 159683 | None | code30 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. | Sqm | 2142.0 | 2142.0 | 4.73 | False | None | None | False | None | False | 10131.66 | 0 |
4099072 | 159683 | None | code31 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 110mm(weight of pipe -1.894 kg) | m | 413.7 | 413.7 | 18.0 | False | None | None | False | None | False | 7446.6 | 0 |
4099073 | 159683 | None | code32 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick | m | 61.0 | 61.0 | 30.0 | False | None | None | False | None | False | 1830.0 | 0 |
4099074 | 159683 | None | code33 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick | m | 70.0 | 70.0 | 30.0 | False | None | None | False | None | False | 2100.0 | 0 |
4099075 | 159683 | None | code34 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 75 x 75 x 65 mm | Each | 100.0 | 100.0 | 1.0 | False | None | None | False | None | False | 100.0 | 0 |
4099076 | 159683 | None | code35 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 200 x 90 x 65 mm | Each | 169.0 | 169.0 | 2.0 | False | None | None | False | None | False | 338.0 | 0 |
4099077 | 159683 | None | code36 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 180 x 90 x 65 mm | Each | 119.0 | 119.0 | 1.0 | False | None | None | False | None | False | 119.0 | 0 |
4099078 | 159683 | None | code37 | Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box | Each | 49.0 | 49.0 | 5.0 | False | None | None | False | None | False | 245.0 | 0 |
4099079 | 159683 | None | code38 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box | Each | 51.0 | 51.0 | 1.0 | False | None | None | False | None | False | 51.0 | 0 |
4099080 | 159683 | None | code39 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wall | m | 26.0 | 26.0 | 30.0 | False | None | None | False | None | False | 780.0 | 0 |
4099081 | 159683 | None | code40 | Supplying And Fixing Metal Fan Box with Round Hook. | No | 163.0 | 163.0 | 3.0 | False | None | None | False | None | False | 489.0 | 0 |
4099082 | 159683 | None | code41 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch | Point | 276.0 | 276.0 | 6.0 | False | None | None | False | None | False | 1656.0 | 0 |
4099083 | 159683 | None | code42 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 386.0 | 386.0 | 3.0 | False | None | None | False | None | False | 1158.0 | 0 |
4099084 | 159683 | None | code43 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Point | 567.0 | 567.0 | 1.0 | False | None | None | False | None | False | 567.0 | 0 |
4099085 | 159683 | None | code44 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 sqmm | m | 26.0 | 26.0 | 60.0 | False | None | None | False | None | False | 1560.0 | 0 |
4099086 | 159683 | None | code45 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 sqmm | m | 40.0 | 40.0 | 25.0 | False | None | None | False | None | False | 1000.0 | 0 |
4099087 | 159683 | None | code46 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 sqmm | m | 59.0 | 59.0 | 6.0 | False | None | None | False | None | False | 354.0 | 0 |
4099088 | 159683 | None | code47 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module | Each | 152.0 | 152.0 | 3.0 | False | None | None | False | None | False | 456.0 | 0 |
4099089 | 159683 | None | code48 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module | Each | 175.0 | 175.0 | 1.0 | False | None | None | False | None | False | 175.0 | 0 |
4099090 | 159683 | None | code49 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module | Each | 302.0 | 302.0 | 1.0 | False | None | None | False | None | False | 302.0 | 0 |
4099091 | 159683 | None | code50 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 88.0 | 88.0 | 4.0 | False | None | None | False | None | False | 352.0 | 0 |
4099092 | 159683 | None | code51 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket | Each | 249.0 | 249.0 | 4.0 | False | None | None | False | None | False | 996.0 | 0 |
4099093 | 159683 | None | code52 | Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box. | Each | 747.0 | 747.0 | 1.0 | False | None | None | False | None | False | 747.0 | 0 |
4099094 | 159683 | None | code53 | Supplying fully automatic star-delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 V 3 phase and wired after fixing to the existing wooden board for motor. | Each | 6912.0 | 6912.0 | 1.0 | False | None | None | False | None | False | 6912.0 | 0 |
4099095 | 159683 | None | code54 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SP | Each | 523.0 | 523.0 | 1.0 | False | None | None | False | None | False | 523.0 | 0 |
4099096 | 159683 | None | code55 | Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 12 Way SP & N | Each | 2067.0 | 2067.0 | 1.0 | False | None | None | False | None | False | 2067.0 | 0 |
4099097 | 159683 | None | code56 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 7700.0 | 7700.0 | 1.0 | False | None | None | False | None | False | 7700.0 | 0 |
4099098 | 159683 | None | code57 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips | m | 3078.0 | 3078.0 | 1.0 | False | None | None | False | None | False | 3078.0 | 0 |
4099099 | 159683 | None | code58 | Supplying of .....feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI less than 80. Power Input: 220-240V@ 50/60Hz & Power factor less than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 740.0 | 740.0 | 12.0 | False | None | None | False | None | False | 8880.0 | 0 |
4099100 | 159683 | None | code59 | Supplying & Fixing of 70-150 W lamp holder 2 Pin | No | 118.0 | 118.0 | 12.0 | False | None | None | False | None | False | 1416.0 | 0 |
4099101 | 159683 | None | code60 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / Girders | Each | 119.0 | 119.0 | 12.0 | False | None | None | False | None | False | 1428.0 | 0 |
4099102 | 159683 | None | code61 | Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. | Each | 486.0 | 486.0 | 12.0 | False | None | None | False | None | False | 5832.0 | 0 |
4099103 | 159683 | None | code62 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm) | Each | 2997.0 | 2997.0 | 3.0 | False | None | None | False | None | False | 8991.0 | 0 |
4099104 | 159683 | None | code63 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular model | Each | 2085.0 | 2085.0 | 6.0 | False | None | None | False | None | False | 12510.0 | 0 |
4099105 | 159683 | None | code64 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 295.05 | 295.05 | 9.0 | False | None | None | False | None | False | 2655.45 | 0 |
4099106 | 159683 | None | code65 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m | m | 508.2 | 508.2 | 4.05 | False | None | None | False | None | False | 2058.21 | 0 |
4099107 | 159683 | None | code66 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 6 Kg/m2: 63mm(weight of pipe -0.662 kg) | m | 182.09 | 182.09 | 20.0 | False | None | None | False | None | False | 3641.8 | 0 |
4099108 | 159683 | None | code67 | Providing and fixing Chlorinated Polyveny Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes | m | 333.9 | 333.9 | 40.0 | False | None | None | False | None | False | 13356.0 | 0 |
4099109 | 159683 | None | code68 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore | No. | 320.25 | 320.25 | 8.0 | False | None | None | False | None | False | 2562.0 | 0 |
4099110 | 159683 | None | code69 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 2 HP, Size 65x50 Head 13M, Discharge 462 LPM | No | 15610.0 | 15610.0 | 1.0 | False | None | None | False | None | False | 15610.0 | 0 |
4099111 | 159683 | None | code70 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Each | 5128.2 | 5128.2 | 1.0 | False | None | None | False | None | False | 5128.2 | 0 |
4099112 | 159683 | None | code71 | Providing and fixing white vitreous china pedestal type water closet
(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.
flushing cistern, including flush pipe, with manually controlled device
(handle lever), conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 5079.9 | 5079.9 | 1.0 | False | None | None | False | None | False | 5079.9 | 0 |
4099113 | 159683 | None | code72 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern | Each | 4676.7 | 4676.7 | 2.0 | False | None | None | False | None | False | 9353.4 | 0 |
4099114 | 159683 | None | code73 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | l | 9.45 | 9.45 | 1000.0 | False | None | None | False | None | False | 9450.0 | 0 |
4099115 | 159683 | None | code74 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | Each | 3236.1 | 3236.1 | 3.0 | False | None | None | False | None | False | 9708.3 | 0 |
4099116 | 159683 | None | code75 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m including cost of labour, tools and other apurtenances required to complete the work. | Cum | 313.95 | 313.95 | 4.73 | False | None | None | False | None | False | 1484.9835 | 0 |
4099117 | 159683 | None | code76 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 0.34 | False | None | None | False | None | False | 2138.073 | 0 |
4099118 | 159683 | None | code77 | RCC humepipe circular pump house | No. | 14000.0 | 14000.0 | 1.0 | False | None | None | False | None | False | 14000.0 | 0 |
4099119 | 159683 | None | code78 | Errection and positioning of RCC hume pipe. | No. | 1976.1 | 1976.1 | 1.0 | False | None | None | False | None | False | 1976.1 | 0 |
4099120 | 159683 | None | code79 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m including cost of labour, tools and other apurtenances required to complete the work. | Cum | 313.95 | 313.95 | 4.42 | False | None | None | False | None | False | 1387.659 | 0 |
4099121 | 159683 | None | code80 | Supplying and erection of RCC rings for well steining of 0.3mtr depth usingM-20 grade concrete using clean graded granite or trap or jelly of approved quality 20mm and down size well compacted including centering, from work and plastering for both faces with C.M. 1:3 proportion as per design using 6.50mm M.S. coil at the rate of 10kgs/ring including cost of steel and fabrication bailing out of water errection etc., | Each | 1097.25 | 1097.25 | 8.0 | False | None | None | False | None | False | 8778.0 | 0 |
4099122 | 159683 | None | code81 | Providing & fixing RCC Pre-cast Cover Slab of size 0.8 m x 0.8 m x 0.2m of M25-Design mix concrete with 12 mm steel @ 120 mm c/c both ways, over Gate valve extension spindle with central opening along with lid for smooth operation with appurtenances., complete with all lead and lifts etc. complete | Each | 2354.1 | 2354.1 | 1.0 | False | None | None | False | None | False | 2354.1 | 0 |
4099123 | 159683 | None | code82 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 110mm(weight of pipe -1.894 kg) | m | 413.7 | 413.7 | 10.0 | False | None | None | False | None | False | 4137.0 | 0 |
4099124 | 159683 | None | code83 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | 1 chamber | 5924.1 | 5924.1 | 2.0 | False | None | None | False | None | False | 11848.2 | 0 |