4098832 | 159671 | None | code01 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 1746.15 | 1746.15 | 8.6 | False | None | None | False | None | False | 15016.89 | 0 |
4098833 | 159671 | None | code02 | Demolishing brick work manually/ by mechanical means including stack- ing of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 506.1 | 506.1 | 17.75 | False | None | None | False | None | False | 8983.275 | 0 |
4098834 | 159671 | None | code03 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m including cost of labour, tools and other apurtenances required to complete the work. | Cum | 254.1 | 254.1 | 48.57 | False | None | None | False | None | False | 12341.637 | 0 |
4098835 | 159671 | None | code04 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 13.5 | False | None | None | False | None | False | 84894.075 | 0 |
4098836 | 159671 | None | code05 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Sqm0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 6.56 | False | None | None | False | None | False | 43304.856 | 0 |
4098837 | 159671 | None | code06 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11286.56 | 11286.56 | 1.44 | False | None | None | False | None | False | 16252.6464 | 0 |
4098838 | 159671 | None | code07 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10442.25 | 10442.25 | 4.91 | False | None | None | False | None | False | 51271.4475 | 0 |
4098839 | 159671 | None | code08 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 29.57 | False | None | None | False | None | False | 198368.8665 | 0 |
4098840 | 159671 | None | code09 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 45.5 | False | None | None | False | None | False | 22645.35 | 0 |
4098841 | 159671 | None | code10 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 8.62 | False | None | None | False | None | False | 2407.566 | 0 |
4098842 | 159671 | None | code11 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11834.55 | 11834.55 | 3.22 | False | None | None | False | None | False | 38107.251 | 0 |
4098843 | 159671 | None | code12 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10094.18 | 10094.18 | 0.14 | False | None | None | False | None | False | 1413.1852 | 0 |
4098844 | 159671 | None | code13 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11138.4 | 11138.4 | 13.2 | False | None | None | False | None | False | 147026.88 | 0 |
4098845 | 159671 | None | code14 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 12.14 | False | None | None | False | None | False | 101580.843 | 0 |
4098846 | 159671 | None | code15 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 2.1 | False | None | None | False | None | False | 13708.485 | 0 |
4098847 | 159671 | None | code16 | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 93929.85 | 93929.85 | 2.395 | False | None | None | False | None | False | 224961.99075 | 0 |
4098848 | 159671 | None | code17 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 309.75 | 309.75 | 186.78 | False | None | None | False | None | False | 57855.105 | 0 |
4098849 | 159671 | None | code19 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. | Sqm | 4701.9 | 4701.9 | 2.52 | False | None | None | False | None | False | 11848.788 | 0 |
4098850 | 159671 | None | code20 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 176.4 | 176.4 | 226.8 | False | None | None | False | None | False | 40007.52 | 0 |
4098851 | 159671 | None | code21 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. | Sqm | 2994.6 | 2994.6 | 63.2 | False | None | None | False | None | False | 189258.72 | 0 |
4098852 | 159671 | None | code27 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick | m | 78.0 | 78.0 | 60.0 | False | None | None | False | None | False | 4680.0 | 0 |
4098853 | 159671 | None | code28 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick | m | 79.0 | 79.0 | 30.0 | False | None | None | False | None | False | 2370.0 | 0 |
4098854 | 159671 | None | code29 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 200 x 200 x 65 mm | Each | 348.0 | 348.0 | 1.0 | False | None | None | False | None | False | 348.0 | 0 |
4098855 | 159671 | None | code30 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 100 x 75 x 65 mm | Each | 118.0 | 118.0 | 1.0 | False | None | None | False | None | False | 118.0 | 0 |
4098856 | 159671 | None | code31 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module | Each | 344.0 | 344.0 | 1.0 | False | None | None | False | None | False | 344.0 | 0 |
4098857 | 159671 | None | code32 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.3 Module | Each | 161.0 | 161.0 | 1.0 | False | None | None | False | None | False | 161.0 | 0 |
4098858 | 159671 | None | code33 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 143.0 | 143.0 | 6.0 | False | None | None | False | None | False | 858.0 | 0 |
4098859 | 159671 | None | code34 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module | Each | 357.0 | 357.0 | 2.0 | False | None | None | False | None | False | 714.0 | 0 |
4098860 | 159671 | None | code35 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch | Each | 326.0 | 326.0 | 1.0 | False | None | None | False | None | False | 326.0 | 0 |
4098861 | 159671 | None | code36 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch | Each | 180.0 | 180.0 | 1.0 | False | None | None | False | None | False | 180.0 | 0 |
4098862 | 159671 | None | code37 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket | Each | 236.0 | 236.0 | 3.0 | False | None | None | False | None | False | 708.0 | 0 |
4098863 | 159671 | None | code42 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 |
4098864 | 159671 | None | code44 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Point | 1035.0 | 1035.0 | 2.0 | False | None | None | False | None | False | 2070.0 | 0 |
4098865 | 159671 | None | code45 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 sqmm | m | 26.0 | 26.0 | 90.0 | False | None | None | False | None | False | 2340.0 | 0 |
4098866 | 159671 | None | code46 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 sqmm | m | 42.0 | 42.0 | 90.0 | False | None | None | False | None | False | 3780.0 | 0 |
4098867 | 159671 | None | code47 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | m | 2172.0 | 2172.0 | 1.0 | False | None | None | False | None | False | 2172.0 | 0 |
4098868 | 159671 | None | code48 | Bentonite clay slurry for earthing in 50kg bag | m | 368.0 | 368.0 | 1.0 | False | None | None | False | None | False | 368.0 | 0 |
4098869 | 159671 | None | code49 | Digging of Pit for providing GI pipe type Earthing | Per Pit | 759.0 | 759.0 | 1.0 | False | None | None | False | None | False | 759.0 | 0 |
4098870 | 159671 | None | code50 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DP | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 |
4098871 | 159671 | None | code 51 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 |
4098872 | 159671 | None | code 52 | Distempering with oil bound washable distemper of approved brand
and manufacture to give an even shade New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly
brooming the surface to remove all dirt, dust, mortar drops and foreign
matter including preparing the surface even and sand paper smooth, cost
of materials, labour complete as per specifications and as per directions
of Engineer-in-charge | Sqm | 143.85 | 143.85 | 107.08 | False | None | None | False | None | False | 15403.458 | 0 |
4098873 | 159671 | None | code 53 | Finishing walls with Premium Acrylic Smooth exterior paint with
Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up
resistant, Alkali & Water resistant of required shade: New work (Two
coats applied @ 1.43 L/10 m² over and including priming coat of exterior
primer applied @ 2.20 kg/10 m²) with paint of approved quality to give
an even shade, after thoroughly brooming the surface to remove all dirt,
dust, mortar drops and foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge. | Sqm | 186.9 | 186.9 | 108.81 | False | None | None | False | None | False | 20336.589 | 0 |
4098874 | 159671 | None | code 54 | Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade :Two coats on new work after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge | Sqm | 120.75 | 120.75 | 29.3 | False | None | None | False | None | False | 3537.975 | 0 |
4098875 | 159671 | None | code 55 | providing wall black boards in 12mm thick with CM 1:3 and applied with
primer & two coats of acrylic emulsion black paint including finishing
etc.,complete. | Sqm | 498.75 | 498.75 | 4.5 | False | None | None | False | None | False | 2244.375 | 0 |