1727678566000 | 0 | None | None | Water supply/sewage lines | work of Replacement and Realignment of 230mm dia SW sewer line and Construction of machine holes in ward no 15 (1) 2nd cross kalastrinagar to park road kalastrinagar (2) Govt urdu school backside to 4th cross Kalastrinagar coming under MEI Layout 2 Service area of AEE NW-3 Sub-division | 1064660.96 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
4105845 | 160039 | None | code01 | Dismantling of Cement Concrete Pavement.Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 m3 in volume and stock piling at designated locations and disposal of dismantled materials and stacking serviceable and unserviceable
materials separately | Cum | 563.0 | 563.0 | 30.08 | False | None | None | False | None | False | 16935.04 | 0 | 4105846 | 160039 | None | code02 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.All kinds of soils. Depth upto 1.50 m | Cum | 262.0 | 262.0 | 123.63 | False | None | None | False | None | False | 32391.06 | 0 | 4105847 | 160039 | None | code03 | Depth exceeding 1.5m, but not exceeding 3 m | Cum | 331.0 | 331.0 | 26.78 | False | None | None | False | None | False | 8864.18 | 0 | 4105848 | 160039 | None | code04 | Providing lowering laying, jointing, testing and commissioning of following diameters glazed stone ware pipes, conforming to IS 651:1992, (with 5th revision) in all respects jointing with EPDM rubber rings (seals according to EN 681 & ASPM 425) The rubber seals joints pipe will have groves in interior of socket and exterior of the spigot. The rubber gasket shall be prefixed at the factory by the manufacturer rigidly with approved glue to have leak proof joint including conveying of pipe to work site and rolling and lowering into trenches, laying true to line, level and perfect linking at joints testing and commissoning including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of GSW pipes and specials, with rubber gaskets conforming to EN 681 and ASTM C-425 including cleaning the socket and spigot with soap solution and applying talcum powder
for detecting crack, then applying glue and before inserting of rubber gaskets, jacking and fixing in perfect condition including the cost of soap solution, talcum powder and glue etc. and giving necessary hydraulic test to the required pressure of water head with all lead and lifts including costing of jointing materials and all necessary survey works for laying of sewers etc., and disposal of debris as directed etc., complete. (Contractor will make his own arrangements for procuring water for testing) with Rubber ring gasket joints.230 mm dia. pipes | m | 936.0 | 936.0 | 159.2 | False | None | None | False | None | False | 149011.2 | 0 | 4105849 | 160039 | None | code05 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 160.0 | 160.0 | 92.82 | False | None | None | False | None | False | 14851.2 | 0 | 4105850 | 160039 | None | code06 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work | Cum | 85.0 | 85.0 | 57.59 | False | None | None | False | None | False | 4895.15 | 0 | 4105851 | 160039 | None | code07 | Wet Mix Macadam (Plant Mix Method).Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. | Cum | 2559.0 | 2559.0 | 38.21 | False | None | None | False | None | False | 97779.39 | 0 | 4105852 | 160039 | None | code08 | Plain Cement Pavement Quality M30 grade Concrete (RMC) with OPC & GGBS laid without Paver Construction of un-reinforced plain cement concrete pavement using RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90 kg/m3 (75:25 proportion) as per approved mix design procedure and thickness as per design, over a prepared sub base. The superplastisiser confirming to IS 9103-1999 Reaffirmed-2008 ,Coarse aggregates and Fine aggregate confirming to IS:383-2016, transported to site, laid in approved fixed side form work (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work). Spreading the concrete with shovels, rackers and compacted using needle, suitable plate vibrator and finished in a continuous operation including provision of separation membrane and Hessian cloth finishing to lines and grades complete including cost of all materials, labour, all lead & lift, loading charges as per specification & direction of Engineer - incharge of the work. (Groove cutting shall be paid seperately) | Cum | 6774.0 | 6774.0 | 38.21 | False | None | None | False | None | False | 258834.54 | 0 | 4105853 | 160039 | None | code09 | Dismantling the damaged or collapsed Machinehole ,conical in shape, and reconstructing the same for the same dimensions, with machine made wire cut brick in CM 1:4 with ordinary portland cement etc. as per design and specifications. The existing ring, cover and CC beeding to be used. For 1.2M dia.For Machinehole of 1.2M dia and 2.0 M depth | Each | 32296.0 | 32296.0 | 1.0 | False | None | None | False | None | False | 32296.0 | 0 | 4105854 | 160039 | None | code10 | Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia.Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frame | Each | 29047.0 | 29047.0 | 4.0 | False | None | None | False | None | False | 116188.0 | 0 | 4105855 | 160039 | None | code11 | For every additional 0.1m depth(0.0m to 1.0m depth) | Each | 2904.7 | 2904.7 | 40.0 | False | None | None | False | None | False | 116188.0 | 0 | 4105856 | 160039 | None | code12 | Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 2.0 M depth & SFRC cover & frame | Each | 60784.0 | 60784.0 | 2.0 | False | None | None | False | None | False | 121568.0 | 0 | 4105857 | 160039 | None | code13 | For every additional 0.1m depth(1.0m to 2.0m depth) | Each | 3173.7 | 3173.7 | 20.0 | False | None | None | False | None | False | 63474.0 | 0 | 4105858 | 160039 | None | code14 | For every additional 0.1m depth(2.0m to 3.0m depth) | Each | 2853.2 | 2853.2 | 11.0 | False | None | None | False | None | False | 31385.2 | 0 |
|