5644476 | 233337 | None | 001 | Providing,supplying to work site, Submersible Pump Set of 150mm dia
suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl
& Impeller with Low volt Motor as per specifications,as per necessary
ammendments and instructions of engineer incharge of work. RDW SR-2021-22 SOR CODE-P130A , P150A SL.No.11.1, 15.1 Page No 159, 160 5.00 HP /OPEN WELL | Each | 27680.22 | 27680.22 | 1.0 | False | None | None | False | None | False | 27680.22 | 0 |
5644477 | 233337 | None | 002 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. RDW SR-2021-22 SOR CODE-P230B & P230C SL.No.22.2, 22.3 1x3x2.5 m2 | Mtr | 169.95 | 169.95 | 20.0 | False | None | None | False | None | False | 3399.0 | 0 |
5644478 | 233337 | None | 003 | Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) As Per CSR for Water Supply & Sewerage Works 2023-24 Item No:13.27.1 Page no:155 | Each | 3050.0 | 3050.0 | 5.0 | False | None | None | False | None | False | 15250.0 | 0 |
5644479 | 233337 | None | 004 | Hydraulic Bend Thegalvanized mild steel tubes of 6mtr standard length heavy duty (C Class) For Fountain as per Markate Rate | Each | 2550.0 | 2550.0 | 8.0 | False | None | None | False | None | False | 20400.0 | 0 |
5644480 | 233337 | None | 005 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete As Per CSR for Water Supply & Sewerage Works 2023-24 Item No:11.3.2 Page no:128 Heavy Duty GI pipe of 20mm dia | Mtr | 263.0 | 263.0 | 21.0 | False | None | None | False | None | False | 5523.0 | 0 |
5644481 | 233337 | None | 006 | Supply and delivery at site wrought middle steel (galvanized) GI tee
confirming to IS 1239-II, 1991 with latest amendments if any. As Per CSR for Water Supply & Sewerage Works 2023-24 Item No:11.9.6 Page no:130 For 50 mm Dia GI TEE" | Each | 297.0 | 297.0 | 4.0 | False | None | None | False | None | False | 1188.0 | 0 |
5644482 | 233337 | None | 007 | Supply and delivery at site wrought middle steel (galvanized) GI elbow
confirming to IS 1239-II, 1991 with latest amendments if any for: As Per CSR for Water Supply & Sewerage Works 2023-24 Item No:11.7.6 Page no:130 For 50 mm Dia GI Elbow | Each | 267.0 | 267.0 | 3.0 | False | None | None | False | None | False | 801.0 | 0 |
5644483 | 233337 | None | 008 | Supply and delivery at site wrought middle steel (galvanized) GI union
confirming to IS 1239-II, 1991 with latest amendments if any. As Per CSR for Water Supply & Sewerage Works 2023-24 Item No:11.12.6 Page no:131 For 50 mm Dia Union | Each | 267.0 | 267.0 | 2.0 | False | None | None | False | None | False | 534.0 | 0 |
5644484 | 233337 | None | 009 | Supply and delivery at site wrought middle steel (galvanized) GI back
nut/ check nut confirming to IS 1239-II, 1991 with latest amendments
if any. As Per CSR for Water Supply & Sewerage Works 2023-24 Item No:11.13.6 Page no:132 For 50 mm dia GI Back nut/ check nut" | Each | 267.0 | 267.0 | 8.0 | False | None | None | False | None | False | 2136.0 | 0 |
5644485 | 233337 | None | 010 | Supply and delivery at site wrought middle steel (galvanized) GI hexagonal nipple confirming to IS 1239-II, 1991 with latest amendments if any.For 50 mm dia 12" Lenth GI hexagonal nipple As per market Rate | Each | 420.0 | 420.0 | 2.0 | False | None | None | False | None | False | 840.0 | 0 |
5644486 | 233337 | None | 011 | Supply and delivery at site wrought middle steel (galvanized) GI hexagonal nipple confirming to IS 1239-II, 1991 with latest amendments if any.For 50 mm dia 24" Lenth GI hexagonal nipple As per market Rate | Each | 820.0 | 820.0 | 4.0 | False | None | None | False | None | False | 3280.0 | 0 |
5644487 | 233337 | None | 012 | Supply and delivery at site wrought middle steel (galvanized) GI Flange confirming to IS 1239-II, 1991 with latest amendments if any.For 50 mm dia GI Flange As per market Rate | Each | 1400.0 | 1400.0 | 2.0 | False | None | None | False | None | False | 2800.0 | 0 |
5644488 | 233337 | None | 013 | Supply and delivery at site wrought middle steel (galvanized) GI socket
confirming to IS 1239-II, 1991 with latest amendments if any. As Per CSR for Water Supply & Sewerage Works 2023-24 Item No:11.10.6 Page no:131 For 50 mm dia GI socket" | Each | 297.0 | 297.0 | 3.0 | False | None | None | False | None | False | 891.0 | 0 |
5644489 | 233337 | None | 014 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter 3 As Per CSR for Water Supply & Sewerage Works 2023-24 Item No:13.23.1,13.23.2 Page no:155 3 to 6 HP pumps | No | 9550.0 | 9550.0 | 1.0 | False | None | None | False | None | False | 9550.0 | 0 |
5644490 | 233337 | None | 015 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter 3 As Per CSR for Water Supply & Sewerage Works 2023-24 Item No:13.23.1,13.23.2 Page no:155 3Upto 3 HP pumps | No | 6500.0 | 6500.0 | 2.0 | False | None | None | False | None | False | 13000.0 | 0 |
5644491 | 233337 | None | 016 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.As per PWD Ele SR 2-23-24 SL.No-5.7.3 Page No-14 63 A | Each | 401.0 | 401.0 | 3.0 | False | None | None | False | None | False | 1203.0 | 0 |
5644492 | 233337 | None | 017 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898 As per PWD Ele SR 2-23-24SL.No-5.18.7 Page No-17 6-32 A TPN | Each | 1717.0 | 1717.0 | 1.0 | False | None | None | False | None | False | 1717.0 | 0 |
5644493 | 233337 | None | 018 | Supply and fixing of LED floodlight luminaire 11.9.4 LED Street Light 150 watts | No | 11128.0 | 11128.0 | 15.0 | False | None | None | False | None | False | 166920.0 | 0 |
5644494 | 233337 | None | 020 | Supplying ofrecess mounting non integrated type LED down light.W luminaire comprising of pressure decast/extruded aluminium housing,with spring loaded falseceiling c electrical condition. As per PWD Ele SR 2-23-24 SL.No-11.4.2 Page No-44 10-12W | Each | 1269.0 | 1269.0 | 13.0 | False | None | None | False | None | False | 16497.0 | 0 |
5644495 | 233337 | None | 021 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multi strand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS 694:2010 As per PWD Ele SR 2-23-24 Item.No-2.3.3 4 mm2 Page no: 5" | Mtr | 63.0 | 63.0 | 255.0 | False | None | None | False | None | False | 16065.0 | 0 |
5644496 | 233337 | None | 022 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. As Per PWD Ele SR 2-23-24 Item No-5.44.2 Page No-21 300 mm x 450 mm x 214 mm 1) For Lakkundi house Opp High mast & 2) Ward no:07 Opp Veerabhadreshwar temple Tenginkai bazar High mast | Each | 6163.0 | 6163.0 | 2.0 | False | None | None | False | None | False | 12326.0 | 0 |
5644497 | 233337 | None | 023 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013
with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of
elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing
the pipes alround to a depth of not less than 15 cms. with soft gravel
or selected earth available from the excavation etc. complete and giving
necessary hydraulic test to the required pressure as per ISS (contractor
will make his own arrangements for procuring water for testing) etc.
complete for:As Per CSR for Water Supply & Sewerage Works 2023-24 Item No:10.2.1 Page no:114 Pipes of SN 4, 75mm dia | Mtr | 217.0 | 217.0 | 10.0 | False | None | None | False | None | False | 2170.0 | 0 |
5644498 | 233337 | None | 024 | Supplying of 170mm dia End cap | No | 250.0 | 250.0 | 1.0 | False | None | None | False | None | False | 250.0 | 0 |
5644499 | 233337 | None | 025 | NON RETURN VALVE: Supply & delivery of brand new best make Non-return valve confirming to IS-778-84 with ISI mark.and as per its latest amendments.As Per CSR for Water Supply & Sewerage Works 2023-24 Item No:13.25.1 Page no:154 For 50 mm | Each | 1250.0 | 1250.0 | 1.0 | False | None | None | False | None | False | 1250.0 | 0 |
5644500 | 233337 | None | 026 | Supply of PPR Double Union Ball Valve confirming to IS 15801-2008 and
DIN Standards 8077/8092 As Per CSR for Water Supply & Sewerage Works 2023-24 Item No:2.82.1 Page no:41 PPR Double Union Ball Valve 20mm | Each | 789.0 | 789.0 | 1.0 | False | None | None | False | None | False | 789.0 | 0 |
5644501 | 233337 | None | 027 | Providing wrought mild steel (galvanized) GI collar confirming to IS
1239-II, 1991 with latest amendments if any. As Per CSR for Water Supply & Sewerage Works 2023-24 Item No:11.6.1 Page no:129 For 15 mm dia GI collar | Each | 59.0 | 59.0 | 6.0 | False | None | None | False | None | False | 354.0 | 0 |
5644502 | 233337 | None | 028 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. SR 2021-22 Pg No 6 Item No 1.5 V-1 | Cum | 240.45 | 240.45 | 10.8 | False | None | None | False | None | False | 2596.86 | 0 |
5644503 | 233337 | None | 029 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (As per PWD SR2021-22 Vol-I pg No.A60 It no.1.10) | Cum | 168.0 | 168.0 | 10.8 | False | None | None | False | None | False | 1814.4 | 0 |
5644504 | 233337 | None | 030 | Supply and Fixing Of Fountain Nozzle as per Site Incharge engineer Direction As Per Markate Rate
| No | 650.0 | 650.0 | 12.0 | False | None | None | False | None | False | 7800.0 | 0 |
5644505 | 233337 | None | 031 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : (RDWSR 2021-22 (SOR CODE-K010A SL.No-1.1) HDPE Grade PE80-PN6.0, 63 mm dia | Mtr | 152.44 | 152.44 | 30.0 | False | None | None | False | None | False | 4573.2 | 0 |
5644506 | 233337 | None | 032 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 As per ESCOMs SR 2023-24 Item No:32.05 Sl No:201 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) | Mtr | 141.84 | 141.84 | 35.0 | False | None | None | False | None | False | 4964.4 | 0 |
5644507 | 233337 | None | 033 | Labour charges for laying of 1.1 kv class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. In existing trench / duct. 25 sqmm to 75 sqmm … incluidng cost of all materials, labour, HOM, I & UL, curing with all leads and lifts etc. complete as per specifications & as directed by engineer-in-charge of the work. (PWD Ele SR 2019-20 P.NO. 41 I.NO. 6.5.2) | Mtr | 11.88 | 11.88 | 35.0 | False | None | None | False | None | False | 415.8 | 0 |
5644508 | 233337 | None | 034 | Supplying Galvanized steel flexible conduit pipe.mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamp edusing heavy gauge saddles ataninterval of300 mm using NFscrew sand on either end of the pipe terminate dcompletely As per PWD Ele SR 2-23-24 Item.No- 1.10.1 Page no: 3 20 mm | Mtr | 53.0 | 53.0 | 60.0 | False | None | None | False | None | False | 3180.0 | 0 |
5644509 | 233337 | None | 035 | Wiring for lighting/power circuit using one of FRLS PVC insulted 1.1 kV grade multi strand copper with low conductor resistance 4 Sqmm single core wire in open are concealed system of wiring with specified IS-694-1990 and conform into GTP of group A . As per ESCOMs SR 2023-24 Item.No- 14.03 Page no: 62 4 sqmm Aluminium wire | Mtr | 49.0 | 49.0 | 30.0 | False | None | None | False | None | False | 1470.0 | 0 |